These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 34587303)

  • 1. Effect of different dental implant drilling template designs on heat generation during osteotomy - an in vitro study.
    Waltenberger L; Wied S; Wolfart S; Tuna T
    Clin Oral Implants Res; 2022 Jan; 33(1):53-64. PubMed ID: 34587303
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex vivo study.
    Gehrke SA; Aramburú Júnior JS; Pérez-Albacete Martínez C; Ramirez Fernandez MP; Maté Sánchez de Val JE; Calvo-Guirado JL
    Clin Oral Implants Res; 2018 Jul; 29(7):772-778. PubMed ID: 27041138
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model.
    Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD
    Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Numerical and Experimental Analyses on the Temperature Distribution in the Dental Implant Preparation Area when Using a Surgical Guide.
    Liu YF; Wu JL; Zhang JX; Peng W; Liao WQ
    J Prosthodont; 2018 Jan; 27(1):42-51. PubMed ID: 27078175
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of the Combination of Low-Speed Drilling and Cooled Irrigation Fluid on Intraosseous Heat Generation During Guided Surgical Implant Site Preparation: An In Vitro Study.
    Barrak I; Joób-Fancsaly A; Varga E; Boa K; Piffko J
    Implant Dent; 2017 Aug; 26(4):541-546. PubMed ID: 28542041
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of surgical drill guide on heat generated from implant drilling.
    Misir AF; Sumer M; Yenisey M; Ergioglu E
    J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.
    Marković A; Lazić Z; Mišić T; Šćepanović M; Todorović A; Thakare K; Janjić B; Vlahović Z; Glišić M
    Vojnosanit Pregl; 2016 Aug; 73(8):744-50. PubMed ID: 29328609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model.
    Strbac GD; Unger E; Donner R; Bijak M; Watzek G; Zechner W
    Clin Oral Implants Res; 2014 Jun; 25(6):665-74. PubMed ID: 23009204
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study.
    Salomó-Coll O; Auriol-Muerza B; Lozano-Carrascal N; Hernández-Alfaro F; Wang HL; Gargallo-Albiol J
    Clin Oral Investig; 2021 Mar; 25(3):1047-1053. PubMed ID: 32533265
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of a Novel Drill Design on Heat Generation During Conventional and Guided Implant Osteotomy.
    Kuster M; Mukaddam K; Zitzmann NU; Filippi A; Kühl S
    Int J Oral Maxillofac Implants; 2021; 36(3):e31-e41. PubMed ID: 34115057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy.
    Orgev A; Gonzaga L; Martin W; Morton D; Lin WS
    J Prosthet Dent; 2021 Aug; 126(2):164-166. PubMed ID: 32800579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Heat and Sound Generation During Implant Osteotomy When Using Different Types of Drills in Artificial and Bovine Bone Blocks.
    Limmeechokchai S; Kan JY; Rungcharassaeng K; Goodacre CJ; Lozada J; Oyoyo U
    J Oral Implantol; 2022 Jun; 48(3):187-193. PubMed ID: 34091687
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: an in vitro study.
    Abuhajar E; Salim NA; Sallam M; Jarab F; Satterthwaite JD
    BMC Oral Health; 2023 May; 23(1):273. PubMed ID: 37165353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants.
    Bulloch SE; Olsen RG; Bulloch B
    Int J Oral Maxillofac Implants; 2012; 27(6):1456-60. PubMed ID: 23189297
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone.
    Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD
    Clin Implant Dent Relat Res; 2023 Feb; 25(1):152-165. PubMed ID: 36369670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. External cooling efficiently controls intraosseous temperature rise caused by drilling in a drilling guide system: an in vitro study.
    Boa K; Varga E; Pinter G; Csonka A; Gargyan I; Varga E
    Br J Oral Maxillofac Surg; 2015 Dec; 53(10):963-7. PubMed ID: 26250363
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intra-osseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study.
    Gargallo-Albiol J; Salomó-Coll O; Lozano-Carrascal N; Wang HL; Hernández-Alfaro F
    Clin Oral Implants Res; 2021 May; 32(5):590-597. PubMed ID: 33629419
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.
    Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL
    Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Heat production by 3 implant drill systems after repeated drilling and sterilization.
    Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM
    J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation between intraosseous thermal change and drilling impulse data during osteotomy within autonomous dental implant robotic system: An in vitro study.
    Zhao R; Xie R; Ren N; Li Z; Zhang S; Liu Y; Dong Y; Yin AA; Zhao Y; Bai S
    Clin Oral Implants Res; 2024 Mar; 35(3):258-267. PubMed ID: 38031528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.