These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Investigation of Radiation Dose Estimates and Image Quality Between Commercially Available Interventional Fluoroscopy Systems for Fluoroscopically Guided Interventional Procedures. Trunz LM; Eschelman DJ; Gonsalves CF; Adamo RD; Dave JK Acad Radiol; 2021 Nov; 28(11):1559-1569. PubMed ID: 32224035 [TBL] [Abstract][Full Text] [Related]
23. Extending the IAEA-AAPM TRS-483 methodology for radiation therapy machines with field sizes down to 10 × 2 cm Mirzakhanian L; Bassalow R; Huntzinger C; Seuntjens J Med Phys; 2020 Oct; 47(10):5209-5221. PubMed ID: 32815187 [TBL] [Abstract][Full Text] [Related]
24. BEAM QUALITY CORRECTION FACTORS FOR KAP METERS FOR LIGHTLY AND HEAVILY FILTERED X-RAY BEAMS. Herrnsdorf L; Petersson H Radiat Prot Dosimetry; 2016 Jun; 169(1-4):347-52. PubMed ID: 26994096 [TBL] [Abstract][Full Text] [Related]
25. Conversion factors of effective and equivalent organ doses with the air kerma area product in patients undergoing coronary angiography and percutaneous coronary interventions. Brambilla M; Cannillo B; Matheoud R; Compagnone G; Rognoni A; Bongo AS; Carriero A Phys Med; 2017 Oct; 42():189-196. PubMed ID: 29173914 [TBL] [Abstract][Full Text] [Related]
26. A new Diamentor for measuring kerma-area product and air-kerma simultaneously. Gfirtner H; Stieve FE; Wild J Med Phys; 1997 Dec; 24(12):1954-9. PubMed ID: 9434978 [TBL] [Abstract][Full Text] [Related]
27. Accuracy of HVL measurements utilizing solid state detectors for radiography and fluoroscopy X-ray systems. Lin PP; Goode AR J Appl Clin Med Phys; 2021 Sep; 22(9):339-344. PubMed ID: 34375033 [TBL] [Abstract][Full Text] [Related]
28. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190. Lin PJ; Schueler BA; Balter S; Strauss KJ; Wunderle KA; LaFrance MT; Kim DS; Behrman RH; Shepard SJ; Bercha IH Med Phys; 2015 Dec; 42(12):6815-29. PubMed ID: 26632039 [TBL] [Abstract][Full Text] [Related]
29. Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector. Geijer H Acta Radiol Suppl; 2002 Mar; 43(427):1-43. PubMed ID: 12108231 [TBL] [Abstract][Full Text] [Related]
30. A study on the impact of operator experience on the patient radiation exposure in coronary angiography examinations. Mesbahi A; Aslanabadi N; Mehnati P Radiat Prot Dosimetry; 2008; 132(3):319-23. PubMed ID: 19088105 [TBL] [Abstract][Full Text] [Related]
31. [Accuracy Evaluation of Air Kerma-area Product of Over-couch-type X-ray Fluoroscopic System]. Segawa K; Yoshikawa R; Noto K; Matsubara K; Matsuura Y Nihon Hoshasen Gijutsu Gakkai Zasshi; 2022 Nov; 78(11):1349-1357. PubMed ID: 36328484 [TBL] [Abstract][Full Text] [Related]
32. Comparison of a contrast-to-noise ratio-driven exposure control and a regular detector dose-driven exposure control in abdominal imaging in a clinical angiography system. Werncke T; Kemling M; Tashenov S; Hinrichs JB; Meine TC; Maschke SK; Kyriakou Y; Wacker FK; Meyer BC Med Phys; 2021 Dec; 48(12):7641-7656. PubMed ID: 34651705 [TBL] [Abstract][Full Text] [Related]
33. The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters. Lin PJ Med Phys; 2007 Aug; 34(8):3169-72. PubMed ID: 17879779 [TBL] [Abstract][Full Text] [Related]
34. Relationship of beam angulation and radiation exposure in the cardiac catheterization laboratory. Agarwal S; Parashar A; Bajaj NS; Khan I; Ahmad I; Heupler FA; Bunte M; Modi DK; Tuzcu EM; Kapadia SR JACC Cardiovasc Interv; 2014 May; 7(5):558-66. PubMed ID: 24746652 [TBL] [Abstract][Full Text] [Related]
35. Neurointerventions on two generations of angiography systems: Recent systems reduce radiation exposure by half. Li X; Yang K; Marschall TA; Rehani MM; Liu B Phys Med; 2024 Jan; 117():103180. PubMed ID: 38042063 [TBL] [Abstract][Full Text] [Related]
36. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co. Snow JR; Micka JA; DeWerd LA Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881 [TBL] [Abstract][Full Text] [Related]
37. [A Simple Measurement Method for Verifying the Accuracy of the Displayed Dose on an Over-couch-type X-ray Fluoroscopic System]. Noto K; Segawa K; Yoshikawa R; Moribe R; Kojima H; Matsubara K; Takemura A Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021; 77(10):1180-1185. PubMed ID: 34670925 [TBL] [Abstract][Full Text] [Related]
38. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters. Hetland PO; Friberg EG; Ovrebø KM; Bjerke HH Acta Oncol; 2009; 48(2):289-94. PubMed ID: 18759141 [TBL] [Abstract][Full Text] [Related]
39. An international calibration of Kerma-Area Product meters for patient dose optimisation study. Jankowski J; Domienik J; Papierz S; Padovani R; Vano E; Faulkner K Radiat Prot Dosimetry; 2008; 129(1-3):328-32. PubMed ID: 18319283 [TBL] [Abstract][Full Text] [Related]