These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 34613267)
1. Phase-error-compensation-based surface recovery algorithm using spectrum selection for white light interferometry. Ma L; Zhao Y; Du MY; Pei X; Feng XJ; Sun FM; Fang SB Appl Opt; 2021 Jul; 60(21):6030-6043. PubMed ID: 34613267 [TBL] [Abstract][Full Text] [Related]
2. Phase noise estimation based white light scanning interferometry for high-accuracy surface profiling. Ma L; Zhao Y; Pei X; Liu YZ; Sun FM; Wu S Opt Express; 2022 Mar; 30(7):11912-11922. PubMed ID: 35473124 [TBL] [Abstract][Full Text] [Related]
3. A Novel Surface Recovery Algorithm for Dual Wavelength White LED in Vertical Scanning Interferometry (VSI). Zhu L; Dong Y; Li Z; Zhang X Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32933199 [TBL] [Abstract][Full Text] [Related]
4. A rapid measurement method for structured surface in white light interferometry. Lei Z; Liu X; Zhao LI; Yang W; Chen C; Guo X J Microsc; 2019 Dec; 276(3):118-127. PubMed ID: 31696930 [TBL] [Abstract][Full Text] [Related]
5. Surface recovery algorithm in white light interferometry based on combined white light phase shifting and fast Fourier transform algorithms. Vo Q; Fang F; Zhang X; Gao H Appl Opt; 2017 Oct; 56(29):8174-8185. PubMed ID: 29047682 [TBL] [Abstract][Full Text] [Related]
6. Correction of PZT scanner errors using a phase compensation method in white-light phase-shifting interferometry. Kim N; Kwon S Appl Opt; 2021 Oct; 60(30):9311-9318. PubMed ID: 34807066 [TBL] [Abstract][Full Text] [Related]
7. Compensation of phase change on reflection in white-light interferometry for step height measurement. Park MC; Kim SW Opt Lett; 2001 Apr; 26(7):420-2. PubMed ID: 18040340 [TBL] [Abstract][Full Text] [Related]
8. Pseudo Wigner-Ville distribution for 3D white light scanning interferometric measurement. Liang H; Yao D; Shen H Opt Express; 2022 Oct; 30(22):40540-40556. PubMed ID: 36298985 [TBL] [Abstract][Full Text] [Related]
9. A polarized low-coherence interferometry demodulation algorithm by recovering the absolute phase of a selected monochromatic frequency. Jiang J; Wang S; Liu T; Liu K; Yin J; Meng X; Zhang Y; Wang S; Qin Z; Wu F; Li D Opt Express; 2012 Jul; 20(16):18117-26. PubMed ID: 23038359 [TBL] [Abstract][Full Text] [Related]
10. Sub-sampling low coherence scanning interferometry and its application: refractive index measurements of a silicon wafer. Joo KN Appl Opt; 2013 Dec; 52(36):8644-9. PubMed ID: 24513929 [TBL] [Abstract][Full Text] [Related]
11. Gap-matching algorithm with the impCEEMDAN in scanning white-light interference microscopy. Sang M; Du X; Wang S; Xu T; Dong J; Liu T Opt Express; 2020 May; 28(10):15101-15111. PubMed ID: 32403543 [TBL] [Abstract][Full Text] [Related]
12. Proposed algorithm for phase unwrapping. He XY; Kang X; Tay CJ; Quan C; Shang HM Appl Opt; 2002 Dec; 41(35):7422-8. PubMed ID: 12502299 [TBL] [Abstract][Full Text] [Related]
13. A Micro-Topography Measurement and Compensation Method for the Key Component Surface Based on White-Light Interferometry. Chen J; Wang B; Chen X; Jiang Q; Feng W; Xu Z; Zhao Z Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837137 [TBL] [Abstract][Full Text] [Related]
14. Local frequency and envelope estimation by Teager-Kaiser energy operators in white-light scanning interferometry. Salzenstein F; Montgomery P; Boudraa AO Opt Express; 2014 Jul; 22(15):18325-34. PubMed ID: 25089452 [TBL] [Abstract][Full Text] [Related]