These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 34614847)

  • 1. Temperature errors in two-color pyrometry simultaneously considering reflection and combustion gas radiation.
    Huang Y; Long J; Chen D; Long M; Yang Z; Li C
    Opt Express; 2021 Aug; 29(16):25084-25099. PubMed ID: 34614847
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-color pyrometry system to eliminate optical errors for spatially resolved measurements in flames.
    Reggeti SA; Agrawal AK; Bittle JA
    Appl Opt; 2019 Nov; 58(32):8905-8913. PubMed ID: 31873674
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of a two-wavelength pyrometer system and spectral pyrometry for high-temperature measurements.
    Aljohani SB; Alshunaifi IA; Alqahtani NB; Alfarraj BA
    Appl Opt; 2024 May; 63(13):3648-3657. PubMed ID: 38856551
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments.
    Neupane S; Jatana GS; Lutz TP; Partridge WP
    Sensors (Basel); 2022 Dec; 23(1):. PubMed ID: 36616704
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Double modulation pyrometry: A radiometric method to measure surface temperatures of directly irradiated samples.
    Potamias D; Alxneit I; Wokaun A
    Rev Sci Instrum; 2017 Sep; 88(9):095112. PubMed ID: 28964240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of char combustion kinetics parameters: comparison of point detector and imaging-based particle-sizing pyrometry.
    Schiemann M; Geier M; Shaddix CR; Vorobiev N; Scherer V
    Rev Sci Instrum; 2014 Jul; 85(7):075114. PubMed ID: 25085180
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noncontact surface temperature measurement by means of a modulated photothermal effect.
    Loarer T; Greffet JJ; Huetz-Aubert M
    Appl Opt; 1990 Mar; 29(7):979-87. PubMed ID: 20562945
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two-color optical charge-coupled-device-based pyrometer using a two-peak filter.
    Fu T; Zhao H; Zeng J; Zhong M; Shi C
    Rev Sci Instrum; 2010 Dec; 81(12):124903. PubMed ID: 21198043
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comprehensive evaluation of the influence of air combustion and oxy-fuel combustion flue gas constituents on Hg(0) re-emission in WFGD systems.
    Ochoa-González R; Díaz-Somoano M; Martínez-Tarazona MR
    J Hazard Mater; 2014 Jul; 276():157-63. PubMed ID: 24887118
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Temperature measurement with compositional correction of gas mixture based on laser-induced plasma.
    Li S; Dong M; Cheng L; Luo F; Zhao W; Lu J
    Appl Opt; 2020 Sep; 59(25):7638-7645. PubMed ID: 32902464
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics.
    Fu T; Cheng X; Yang Z
    Appl Opt; 2008 Nov; 47(32):6112-23. PubMed ID: 19002237
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Measurement on gas temperature distribution by tunable diode laser absorption spectroscopy].
    Li N; Yan JH; Wang F; Chi Y; Cen KF
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Aug; 28(8):1708-12. PubMed ID: 18975785
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface temperature estimation in determined multi-wavelength pyrometry systems.
    Araújo A; Silva R
    Rev Sci Instrum; 2020 May; 91(5):054901. PubMed ID: 32486728
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In Situ Measurement of NO, NO
    Li J; Li R; Liu Y; Li F; Lin X; Yu X; Shao W; Xu X
    Sensors (Basel); 2022 Jul; 22(15):. PubMed ID: 35957286
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation temperature measurement method for semitransparent materials using one-channel infrared pyrometer.
    Fu T; Liu J; Zong A
    Appl Opt; 2014 Oct; 53(29):6830-9. PubMed ID: 25322390
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Combustion and NOx emission characteristics with respect to staged-air damper opening in a 600 MWe down-fired pulverized-coal furnace under deep-air-staging conditions.
    Kuang M; Li Z; Wang Z; Jing X; Liu C; Zhu Q; Ling Z
    Environ Sci Technol; 2014; 48(1):837-44. PubMed ID: 24274316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of high dynamic range imaging for quantitative combustion diagnostics.
    Giassi D; Liu B; Long MB
    Appl Opt; 2015 May; 54(14):4580-8. PubMed ID: 25967519
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation on gaseous pollutants emissions during co-combustion of coal and wheat straw in a fluidized bed combustor.
    Xue Z; Zhong Z; Lai X
    Chemosphere; 2020 Feb; 240():124853. PubMed ID: 31563712
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Numerical prediction of radiative heat transfer in reciprocating superadiabatic combustion in porous media.
    Du L; Xie M
    J Environ Sci (China); 2011 Jun; 23 Suppl():S26-31. PubMed ID: 25084588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Turbine blade temperature error as measured with an optical pyrometer under different wavelengths and blade TBC thickness.
    Li D; Feng C; Daniel K; Gao S; Chen L; Kang Z
    Appl Opt; 2019 Mar; 58(7):1626-1630. PubMed ID: 30874194
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.