These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 34615075)

  • 21. Low-cost whole slide imaging system with single-shot autofocusing based on color-multiplexed illumination and deep learning.
    Xin K; Jiang S; Chen X; He Y; Zhang J; Wang H; Liu H; Peng Q; Zhang Y; Ji X
    Biomed Opt Express; 2021 Sep; 12(9):5644-5657. PubMed ID: 34692206
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Contrast and resolution enhanced optical sectioning in scattering tissue using line-scanning two-photon structured illumination microscopy.
    Li Z; Hou J; Suo J; Qiao C; Kong L; Dai Q
    Opt Express; 2017 Dec; 25(25):32010-32020. PubMed ID: 29245869
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A Rapid Nanofocusing Method for a Deep-Sea Gene Sequencing Microscope Based on Critical Illumination.
    Gao M; Shu F; Zhou W; Li H; Wu Y; Wang Y; Zhao S; Song Z
    Sensors (Basel); 2024 Aug; 24(15):. PubMed ID: 39124058
    [TBL] [Abstract][Full Text] [Related]  

  • 24. High Resolution of Plasmonic Resonance Scattering Imaging with Deep Learning.
    Song MK; Ma YP; Liu H; Hu PP; Huang CZ; Zhou J
    Anal Chem; 2022 Mar; 94(11):4610-4616. PubMed ID: 35275492
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Label-free 3D imaging of weakly absorbing samples using spatially-incoherent annular illumination microscopy.
    Ma X; Zhou B; Su Z; Zhang Z; Peng J; Zhong J
    Ultramicroscopy; 2019 May; 200():97-104. PubMed ID: 30851712
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Enhanced 3D spatial resolution in quantitative phase microscopy using spatially incoherent illumination.
    Bon P; Aknoun S; Monneret S; Wattellier B
    Opt Express; 2014 Apr; 22(7):8654-71. PubMed ID: 24718236
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bright-field holography: cross-modality deep learning enables snapshot 3D imaging with bright-field contrast using a single hologram.
    Wu Y; Luo Y; Chaudhari G; Rivenson Y; Calis A; de Haan K; Ozcan A
    Light Sci Appl; 2019; 8():25. PubMed ID: 30854197
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Epi-illumination dark-field microscopy enables direct visualization of unlabeled small organisms with high spatial and temporal resolution.
    Shi R; Chen X; Huo J; Guo S; Smith ZJ; Chu K
    J Biophotonics; 2022 Jan; 15(1):e202100185. PubMed ID: 34480418
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Multiplane differential phase contrast imaging using asymmetric illumination in volume holographic microscopy.
    Chia YH; Vyas S; Tsai JC; Huang YY; Yeh JA; Luo Y
    J Biomed Opt; 2020 Nov; 25(12):. PubMed ID: 33247561
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fluorescence Talbot microscope using incoherent source.
    Sun Y; Pang S
    J Biomed Opt; 2016 Aug; 21(8):86003. PubMed ID: 27533440
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pupil-aberration calibration with controlled illumination for quantitative phase imaging.
    Baek Y; Hugonnet H; Park Y
    Opt Express; 2021 Jul; 29(14):22127-22135. PubMed ID: 34265984
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Field-portable quantitative lensless microscopy based on translated speckle illumination and sub-sampled ptychographic phase retrieval.
    Zhang H; Bian Z; Jiang S; Liu J; Song P; Zheng G
    Opt Lett; 2019 Apr; 44(8):1976-1979. PubMed ID: 30985789
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Functional imaging with dynamic quantitative oblique back-illumination microscopy.
    Casteleiro Costa P; Wang B; Filan C; Bowles-Welch A; Yeago C; Roy K; Robles FE
    J Biomed Opt; 2022 Jun; 27(6):. PubMed ID: 35773755
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography.
    Karamata B; Lambelet P; Laubscher M; Salathé RP; Lasser T
    Opt Lett; 2004 Apr; 29(7):736-8. PubMed ID: 15072375
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simultaneous multi-color optical sectioning fluorescence microscopy with wavelength-coded volume holographic gratings.
    Chia YH; Yeh JA; Huang YY; Luo Y
    Opt Express; 2020 Dec; 28(25):37177-37187. PubMed ID: 33379556
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quantitative phase-amplitude microscopy I: optical microscopy.
    Barone-Nugent ED; Barty A; Nugent KA
    J Microsc; 2002 Jun; 206(Pt 3):194-203. PubMed ID: 12067363
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Lensless Three-Dimensional Quantitative Phase Imaging Using Phase Retrieval Algorithm.
    Anand V; Katkus T; Linklater DP; Ivanova EP; Juodkazis S
    J Imaging; 2020 Sep; 6(9):. PubMed ID: 34460756
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Single-shot Fresnel incoherent correlation holography via deep learning based phase-shifting technology.
    Huang T; Zhang Q; Li J; Lu X; Di J; Zhong L; Qin Y
    Opt Express; 2023 Apr; 31(8):12349-12356. PubMed ID: 37157396
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-dimensional tomographic microscopy technique with multi-frequency combination with partially coherent illuminations.
    Li J; Chen Q; Sun J; Zhang J; Ding J; Zuo C
    Biomed Opt Express; 2018 Jun; 9(6):2526-2542. PubMed ID: 30258670
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quantitative phase imaging using a partitioned detection aperture.
    Parthasarathy AB; Chu KK; Ford TN; Mertz J
    Opt Lett; 2012 Oct; 37(19):4062-4. PubMed ID: 23027279
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.