166 related articles for article (PubMed ID: 34619664)
1. Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study.
Prasada DNY; Ciamaudi N; Fadli M; Tursinah R; Pawiro SA
Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34619664
[TBL] [Abstract][Full Text] [Related]
2. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
Chibani O; Ma CM
Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
[TBL] [Abstract][Full Text] [Related]
3. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.
Nedaie HA; Darestani H; Banaee N; Shagholi N; Mohammadi K; Shahvar A; Bayat E
J Med Phys; 2014 Jan; 39(1):10-7. PubMed ID: 24600167
[TBL] [Abstract][Full Text] [Related]
4. Neutron dose equivalent and neutron spectra in tissue for clinical linacs operating at 15, 18 and 20 MV.
Martínez-Ovalle SA; Barquero R; Gómez-Ros JM; Lallena AM
Radiat Prot Dosimetry; 2011 Nov; 147(4):498-511. PubMed ID: 21233098
[TBL] [Abstract][Full Text] [Related]
5. The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.
Ghavami SM; Mesbahi A; Mohammadi E
Radiat Prot Dosimetry; 2010 Feb; 138(2):123-8. PubMed ID: 19789200
[TBL] [Abstract][Full Text] [Related]
6. On the neutron radiation field and air activation around a medical electron linac.
Horst F; Fehrenbacher G; Zink K
Radiat Prot Dosimetry; 2017 Apr; 174(2):147-158. PubMed ID: 27170731
[TBL] [Abstract][Full Text] [Related]
7. Neutron spectra and dosimetric features around an 18 mv linac accelerator.
Barquero R; Mendez R; Vega-Carrillo HR; Iñiguez MP; Edwards TM
Health Phys; 2005 Jan; 88(1):48-58. PubMed ID: 15596989
[TBL] [Abstract][Full Text] [Related]
8. Effects of tertiary MLC configuration on secondary neutron spectra from 18 MV x-ray beams for the Varian 21EX linear accelerator.
Howell RM; Kry SF; Burgett E; Followill D; Hertel NE
Med Phys; 2009 Sep; 36(9):4039-46. PubMed ID: 19810476
[TBL] [Abstract][Full Text] [Related]
9. Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy.
Karimi AH; Brkić H; Shahbazi-Gahrouei D; Haghighi SB; Jabbari I
Appl Radiat Isot; 2019 Mar; 145():24-31. PubMed ID: 30572262
[TBL] [Abstract][Full Text] [Related]
10. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
[TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy.
Kry SF; Titt U; Followill D; Pönisch F; Vassiliev ON; White RA; Stovall M; Salehpour M
Med Phys; 2007 Sep; 34(9):3489-99. PubMed ID: 17926952
[TBL] [Abstract][Full Text] [Related]
12. A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.
Bahreyni Toossi MT; Behmadi M; Ghorbani M; Gholamhosseinian H
J Appl Clin Med Phys; 2013 Sep; 14(5):52-67. PubMed ID: 24036859
[TBL] [Abstract][Full Text] [Related]
13. Photoneutron contamination from an 18 MV Saturne medical linear accelerator in the treatment room.
Khosravi M; Shahbazi-Gahrouei D; Jabbari K; Nasri-Nasrabadi M; Baradaran-Ghahfarokhi M; Siavashpour Z; Gheisari R; Amiri B
Radiat Prot Dosimetry; 2013 Sep; 156(3):356-63. PubMed ID: 23538892
[TBL] [Abstract][Full Text] [Related]
14. Feasibility of 18-MV grid therapy from radiation protection aspects: unwanted dose and fatal cancer risk caused by photoneutrons and scattered photons.
Karimi AH; Mirian SF; Mahmoudi F; Geraily G; Vega-Carrillo HR; Mohiuddin M
Comput Methods Programs Biomed; 2022 Jan; 213():106524. PubMed ID: 34818621
[TBL] [Abstract][Full Text] [Related]
15. Effect of each component of a LINAC therapy head on neutron and photon spectra.
Khabaz R
Appl Radiat Isot; 2018 Sep; 139():40-45. PubMed ID: 29704704
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.
Bednarz B; Xu XG
Phys Med Biol; 2009 Feb; 54(4):N43-57. PubMed ID: 19141879
[TBL] [Abstract][Full Text] [Related]
17. Neutron dose in and out of 18MV photon fields.
Ezzati AO; Studenski MT
Appl Radiat Isot; 2017 Apr; 122():186-192. PubMed ID: 28167445
[TBL] [Abstract][Full Text] [Related]
18. How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
Mahmoudi F; Mohammadi N; Haghighi M; Alirezaei Z; Jabbari I; Chegeni N; Elmtalab S; Vega-Carrillo HR; Kazemian A; Geraily G; Karimi AH
PLoS One; 2023; 18(1):e0280433. PubMed ID: 36638131
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo study of Siemens PRIMUS photoneutron production.
Pena J; Franco L; Gómez F; Iglesias A; Pardo J; Pombar M
Phys Med Biol; 2005 Dec; 50(24):5921-33. PubMed ID: 16333164
[TBL] [Abstract][Full Text] [Related]
20. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?
Ding GX; Duzenli C; Kalach NI
Phys Med Biol; 2002 Sep; 47(17):3251-61. PubMed ID: 12361221
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]