137 related articles for article (PubMed ID: 34624879)
1. The need to update NCRP 151 data for 10 MV linear accelerator bunker shielding based on new measurements and Monte Carlo simulations.
Rijken J; Towns S; Healy B
J Radiol Prot; 2021 Nov; 41(4):. PubMed ID: 34624879
[TBL] [Abstract][Full Text] [Related]
2. Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations.
Beigi M; Afarande F; Ghiasi H
Rep Pract Oncol Radiother; 2016; 21(1):42-9. PubMed ID: 26900357
[TBL] [Abstract][Full Text] [Related]
3. Conservatism in linear accelerator bunker shielding.
Rijken J; Bhat M; Crowe S; Trapp J
Australas Phys Eng Sci Med; 2019 Sep; 42(3):781-787. PubMed ID: 31346964
[TBL] [Abstract][Full Text] [Related]
4. Treatment vault shielding for a flattening filter-free medical linear accelerator.
Kry SF; Howell RM; Polf J; Mohan R; Vassiliev ON
Phys Med Biol; 2009 Mar; 54(5):1265-73. PubMed ID: 19190359
[TBL] [Abstract][Full Text] [Related]
5. Linac primary barrier transmission for concrete: Monte Carlo calculations.
McDermott PN
J Appl Clin Med Phys; 2023 Jan; 24(1):e13847. PubMed ID: 36471480
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study.
Moghaddasi L; Colyer C
Phys Med; 2022 Jun; 98():53-62. PubMed ID: 35490530
[TBL] [Abstract][Full Text] [Related]
7. Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51.
Casanova AO; López N; Gelen A; Guevara MV; Díaz O; Cimino L; D'Alessandro K; Melo JC
Radiat Prot Dosimetry; 2004; 109(3):189-95. PubMed ID: 15254322
[TBL] [Abstract][Full Text] [Related]
8. Does concrete composition affect photoneutron production inside radiation therapy bunkers?
Mesbahi A; Azarpeyvand AA; Khosravi HR
Jpn J Radiol; 2012 Feb; 30(2):162-6. PubMed ID: 22180187
[TBL] [Abstract][Full Text] [Related]
9. Determination of the photon spectrum of a therapeutic linear accelerator near the maze entrance: Comparison of Monte Carlo modeling and measurements using scintillation detectors corrected for pulse pile-up.
Qutub MAZ; Hugtenburg RP; Al-Affan IAM
Med Phys; 2020 Sep; 47(9):4522-4530. PubMed ID: 32469079
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo evaluation of kerma in an HDR brachytherapy bunker.
Pérez-Calatayud J; Granero D; Ballester F; Casal E; Crispin V; Puchades V; León A; Verdú G
Phys Med Biol; 2004 Dec; 49(24):N389-96. PubMed ID: 15724543
[TBL] [Abstract][Full Text] [Related]
11. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
12. Radiation safety of ultra-high dose rate electron accelerators for FLASH radiotherapy.
Præstegaard LH
Med Phys; 2024 Jun; ():. PubMed ID: 38941539
[TBL] [Abstract][Full Text] [Related]
13. Sci-Sat AM: Brachy - 04: Neutron production around a radiation therapy linac bunker - monte carlo simulations and physical measurements.
Khatchadourian R; Davis S; Evans M; Licea A; Seuntjens J; Kildea J
Med Phys; 2012 Jul; 39(7Part4):4645. PubMed ID: 28516634
[TBL] [Abstract][Full Text] [Related]
14. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
Al-Affan IA
Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
[TBL] [Abstract][Full Text] [Related]
15. Linear accelerator bunker shielding for stereotactic radiotherapy.
Rijken J; Bhat M; Crowe S; Kairn T; Trapp J
Phys Med Biol; 2019 Nov; 64(21):21NT04. PubMed ID: 31569089
[TBL] [Abstract][Full Text] [Related]
16. Calculation of shielding door thicknesses for radiation therapy facilities using the ITS Monte Carlo program.
Biggs PJ
Health Phys; 1991 Oct; 61(4):465-72. PubMed ID: 1917483
[TBL] [Abstract][Full Text] [Related]
17. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
Rodgers JE
Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
[TBL] [Abstract][Full Text] [Related]
18. Photoneutron contamination from an 18 MV Saturne medical linear accelerator in the treatment room.
Khosravi M; Shahbazi-Gahrouei D; Jabbari K; Nasri-Nasrabadi M; Baradaran-Ghahfarokhi M; Siavashpour Z; Gheisari R; Amiri B
Radiat Prot Dosimetry; 2013 Sep; 156(3):356-63. PubMed ID: 23538892
[TBL] [Abstract][Full Text] [Related]
19. On the neutron radiation field and air activation around a medical electron linac.
Horst F; Fehrenbacher G; Zink K
Radiat Prot Dosimetry; 2017 Apr; 174(2):147-158. PubMed ID: 27170731
[TBL] [Abstract][Full Text] [Related]
20. Radiotherapy Infrastructure Shielding Calculations: software development for shielding calculations in a linear accelerator radiotherapy room.
Ganou C; Ganos A; Papatheodorou S; Metaxas V; Dimitroukas C; Panayiotakis G
Radiat Prot Dosimetry; 2023 Aug; 199(13):1357-1366. PubMed ID: 37385263
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]