BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 34631231)

  • 1. A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments.
    Lee YC; Kim Y
    J Radiosurg SBRT; 2021; 7(4):295-307. PubMed ID: 34631231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-institution validation of a new high spatial resolution diode array for SRS and SBRT plan pretreatment quality assurance.
    Rose MS; Tirpak L; Van Casteren K; Zack J; Simon T; Schoenfeld A; Simon W
    Med Phys; 2020 Jul; 47(7):3153-3164. PubMed ID: 32215929
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of commercial devices for patient specific QA of stereotactic radiotherapy plans.
    James S; Al-Basheer A; Elder E; Huh C; Ackerman C; Barrett J; Hamilton R; Mostafaei F
    J Appl Clin Med Phys; 2023 Aug; 24(8):e14009. PubMed ID: 37158727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT.
    Stathakis S; Narayanasamy G; Licon AL; Myers P; Li Y; Crownover R; Papanikolaou N
    J BUON; 2019; 24(2):838-843. PubMed ID: 31128044
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A hybrid method to improve efficiency of patient specific SRS and SBRT QA using 3D secondary dose verification.
    Baltz GC; Manigold R; Seier R; Kirsner SM
    J Appl Clin Med Phys; 2023 Mar; 24(3):e13858. PubMed ID: 36583305
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical note: Patient-specific quality assurance for multi-target single-isocenter SRS-A target-specific approach.
    Lee TK
    Med Phys; 2024 May; ():. PubMed ID: 38810282
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Systematic evaluation of spatial resolution and gamma criteria for quality assurance with detector arrays in stereotactic radiosurgery.
    Stedem AK; Tutty M; Chofor N; Langhans M; Kleefeld C; Schönfeld AA
    J Appl Clin Med Phys; 2024 Feb; 25(2):e14274. PubMed ID: 38265979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacious patient-specific QA for Vertebra SBRT using a high-resolution detector array SRS MapCHECK: AAPM TG-218 analysis.
    Berk K; Kron T; Hardcastle N; Yeo AU
    J Appl Clin Med Phys; 2024 Feb; ():e14276. PubMed ID: 38414322
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of TG-218 action limits to SRS and SBRT pre-treatment patient specific QA.
    Xia Y; Adamson J; Zlateva Y; Giles W
    J Radiosurg SBRT; 2020; 7(2):135-147. PubMed ID: 33282467
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SU-E-T-645: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery.
    Huang C; Ren L; Kirkpatrick J; Wang Z
    Med Phys; 2012 Jun; 39(6Part20):3854. PubMed ID: 28517544
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Commissioning and clinical evaluation of a novel high-resolution quality assurance digital detector array for SRS and SBRT.
    Zhou Y; Liu Y; Chen M; Fang J; Xiao L; Huang S; Qi Z; Deng X; Zhang J; Peng Y
    J Appl Clin Med Phys; 2024 Apr; 25(4):e14258. PubMed ID: 38175960
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implementing and evaluating a high-resolution diode array for patient-specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy.
    Xu Q; Huynh K; Nie W; Rose MS; Chawla AK; Choe KS; Kanani S; Kubicek GJ; Fan J
    J Appl Clin Med Phys; 2022 May; 23(5):e13569. PubMed ID: 35278033
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery.
    Pokhrel D; Sood S; McClinton C; Shen X; Badkul R; Jiang H; Mallory M; Mitchell M; Wang F; Lominska C
    Med Dosim; 2017 Spring; 42(1):69-75. PubMed ID: 28129972
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans.
    Ceylan C; Yondem Inal S; Senol E; Yilmaz B; Sahin S
    Cureus; 2021 Jan; 13(1):e12684. PubMed ID: 33598374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of Dosimetric Performance among Commercial Quality Assurance Systems for Verifying Pretreatment Plans of Stereotactic Body Radiotherapy Using Flattening-Filter-Free Beams.
    Chung JB; Kang SW; Eom KY; Song C; Choi KS; Suh TS
    J Korean Med Sci; 2016 Nov; 31(11):1742-1748. PubMed ID: 27709851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA.
    Hillman Y; Kim J; Chetty I; Wen N
    Med Phys; 2018 Apr; 45(4):1351-1359. PubMed ID: 29431865
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy.
    Rauschenbach BM; Mackowiak L; Malhotra HK
    J Appl Clin Med Phys; 2014 Sep; 15(5):4898. PubMed ID: 25207575
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy.
    Mallory M; Pokhrel D; Badkul R; Jiang H; Lominska C; Wang F
    J Appl Clin Med Phys; 2018 Mar; 19(2):54-61. PubMed ID: 29349867
    [TBL] [Abstract][Full Text] [Related]  

  • 19. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT).
    Li G; Bai S; Chen N; Henderson L; Wu K; Xiao J; Zhang Y; Jiang Q; Jiang X
    J Appl Clin Med Phys; 2013 Sep; 14(5):13-24. PubMed ID: 24036856
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.