These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 34634470)

  • 21. Which salvage fixation technique is best for the failed initial screw fixation at the cervicothoracic junction? A biomechanical comparison study.
    Hong JT; Tomoyuki T; Jain A; OrĂ­as AAE; Inoue N; An HS
    Eur Spine J; 2017 Sep; 26(9):2417-2424. PubMed ID: 28752245
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The medial cortical pedicle screw--a new technique for cervical pedicle screw placement with partial drilling of medial cortex.
    Mahesh B; Upendra B; Mahan RS
    Spine J; 2014 Feb; 14(2):371-80. PubMed ID: 24444420
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical comparison of cervical transfacet pedicle screws versus pedicle screws.
    Liu GY; Xu RM; Ma WH; Sun SH; Huang L; Ying JW; Jiang WY
    Chin Med J (Engl); 2008 Aug; 121(15):1390-3. PubMed ID: 18959115
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Quantitative anatomy of subaxial cervical lateral mass: an analysis of safe screw lengths for Roy-Camille and magerl techniques.
    Stemper BD; Marawar SV; Yoganandan N; Shender BS; Rao RD
    Spine (Phila Pa 1976); 2008 Apr; 33(8):893-7. PubMed ID: 18404109
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A novel method of cervical pedicle screw placement from C3 to C5 and its clinical applications.
    Liu J; Li Y; Wu Y; Zhu Q
    Spine (Phila Pa 1976); 2013 Apr; 38(8):E504-12. PubMed ID: 23354110
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Perforations and angulations of 324 cervical medial cortical pedicle screws: a possible guide to avoid lateral perforations with use of pedicle screws in lower cervical spine.
    Mahesh B; Upendra B; Vijay S; Arun K; Srinivasa R
    Spine J; 2017 Mar; 17(3):457-465. PubMed ID: 27865885
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine].
    Zhao LJ; Xu RM; Hua Q; Ma WH; Jiang WY; Zhu YZ
    Zhongguo Gu Shang; 2012 Dec; 25(12):1030-5. PubMed ID: 23627153
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison.
    Jones EL; Heller JG; Silcox DH; Hutton WC
    Spine (Phila Pa 1976); 1997 May; 22(9):977-82. PubMed ID: 9152447
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: a series of 45 consecutive patients.
    Park JH; Jeon SR; Roh SW; Kim JH; Rhim SC
    Spine (Phila Pa 1976); 2014 Feb; 39(4):280-5. PubMed ID: 24299725
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws.
    Tse MS; Chan CH; Wong KK; Wong WC
    Asian Spine J; 2016 Aug; 10(4):705-10. PubMed ID: 27559451
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Considerations for the use of C7 crossing laminar screws in subaxial and cervicothoracic instrumentation.
    Ilgenfritz RM; Gandhi AA; Fredericks DC; Grosland NM; Smucker JD
    Spine (Phila Pa 1976); 2013 Feb; 38(4):E199-204. PubMed ID: 23169075
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology.
    Theologis AA; Burch S
    Spine (Phila Pa 1976); 2015 Sep; 40(18):1397-406. PubMed ID: 26426710
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy and Safety of Lateral Vertebral Notch-Referred Technique Used in Subaxial Cervical Pedicle Screw Placement.
    Pan Z; Zhong J; Xie S; Yu L; Wu C; Ha Y; Kim KN; Zhang Y; Cao K
    Oper Neurosurg (Hagerstown); 2019 Jul; 17(1):52-60. PubMed ID: 30189031
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Radiological considerations of posterior cervical lateral mass fixation using plate and screw.
    Yoon SH; Park HC; Park HS; Kim EY; Ha Y; Chong CK; Kim SM; Rim DC
    Yonsei Med J; 2004 Jun; 45(3):406-12. PubMed ID: 15227726
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Screw-related complications in the subaxial cervical spine with the use of lateral mass versus cervical pedicle screws: a systematic review.
    Yoshihara H; Passias PG; Errico TJ
    J Neurosurg Spine; 2013 Nov; 19(5):614-23. PubMed ID: 24033303
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: accuracy evaluation in cadavers.
    Zheng X; Chaudhari R; Wu C; Mehbod AA; Transfeldt EE
    Eur Spine J; 2010 Jan; 19(1):105-12. PubMed ID: 19916031
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The accuracy of a novel pedicle screw insertion technique assisted by a special angular scale in the subaxial cervical spine using lateral mass as a reference marker.
    Shi H; Zhu L; Ma J; Zhu YC; Wu XT
    J Orthop Surg Res; 2020 Nov; 15(1):551. PubMed ID: 33228707
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Anterior transpedicular screw fixation of cervical spine: Is it safe? Morphological feasibility, technical properties, and accuracy of manual insertion.
    Koktekir E; Toktas ZO; Seker A; Akakin A; Konya D; Kilic T
    J Neurosurg Spine; 2015 Jun; 22(6):596-604. PubMed ID: 25815805
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.
    Sakamoto T; Neo M; Nakamura T
    Spine (Phila Pa 1976); 2004 Nov; 29(22):2510-4; discussion 2515. PubMed ID: 15543062
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software.
    Shin SI; Yeom JS; Kim HJ; Chang BS; Lee CK; Riew KD
    Spine J; 2012 Jul; 12(7):577-84. PubMed ID: 22921806
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.