174 related articles for article (PubMed ID: 34635372)
1. Comparison between 3D delta plate and conventional miniplate in treatment of condylar fracture: A randomised clinical trial.
Ganguly A; Mittal G; Garg R
J Craniomaxillofac Surg; 2021 Nov; 49(11):1026-1034. PubMed ID: 34635372
[TBL] [Abstract][Full Text] [Related]
2. Comparative Evaluation of Clinical Outcomes Using Delta Plates and Conventional Miniplates for Internal Fixation of Mandibular Condylar Fractures in Adults.
Ahuja SA; Galinde J; Asnani U; Mistry YA
J Oral Maxillofac Surg; 2018 Jun; 76(6):1255-1266. PubMed ID: 29360455
[TBL] [Abstract][Full Text] [Related]
3. Three-dimensional v/s standard titanium miniplate fixation in the management of mandibular fractures--a randomized clinical study.
Sehgal S; Ramanujam L; Prasad K; Krishnappa R
J Craniomaxillofac Surg; 2014 Oct; 42(7):1292-9. PubMed ID: 24780350
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of condylar position in anterior mandibular fractures using 3 dimensional miniplate osteosynthesis versus conventional miniplates: Randomized clinical trial.
Mohammad OA; Ashour EM; Hassanein FAA
J Craniomaxillofac Surg; 2022 Jan; 50(1):61-69. PubMed ID: 34756733
[TBL] [Abstract][Full Text] [Related]
5. Fixation of subcondylar fractures of the mandible: a randomized clinical trial comparing one trapezoidal plate with two miniplates.
Adhikari M; Bhatt K; Yadav R; Mandal J; Bhutia O; Roychoudhury A
Int J Oral Maxillofac Surg; 2021 Jun; 50(6):756-762. PubMed ID: 33280989
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional titanium miniplates for fixation of subcondylar mandibular fractures: Comparison of five designs using patient-specific finite element analysis.
Albogha MH; Mori Y; Takahashi I
J Craniomaxillofac Surg; 2018 Mar; 46(3):391-397. PubMed ID: 29311022
[TBL] [Abstract][Full Text] [Related]
7. Functional and radiologic outcome of open reduction and internal fixation of condylar head and neck fractures using miniplate or microplate system.
Xie ST; Singhal D; Chen CT; Chen YR
Ann Plast Surg; 2013 Dec; 71 Suppl 1():S61-6. PubMed ID: 24284743
[TBL] [Abstract][Full Text] [Related]
8. "A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture"--a randomized prospective study.
Vineeth K; Lalitha RM; Prasad K; Ranganath K; Shwetha V; Singh J
J Craniomaxillofac Surg; 2013 Mar; 41(2):103-9. PubMed ID: 22809633
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical Evaluation of Mandibular Condyle Fracture Osteosynthesis Using the Rhombic Three-Dimensional Condylar Fracture Plate.
Ben Achour A; Meißner H; Teicher U; Haim D; Range U; Brosius A; Leonhardt H; Lauer G
J Oral Maxillofac Surg; 2019 Sep; 77(9):1868.e1-1868.e15. PubMed ID: 31112678
[TBL] [Abstract][Full Text] [Related]
10. The retromandibular transparotid approach for reduction and rigid internal fixation using two locking miniplates in mandibular condylar neck fractures.
Kanno T; Sukegawa S; Tatsumi H; Nariai Y; Ishibashi H; Furuki Y; Sekine J
Int J Oral Maxillofac Surg; 2014 Feb; 43(2):177-84. PubMed ID: 24070772
[TBL] [Abstract][Full Text] [Related]
11. The Stability Evaluation of Two Internal Fixation Patterns of Extracapsular Condylar Fracture Based on One Novel Measuring Method.
Liao Q; Liang Z; Zhang P; Xu B; Gui H
J Craniofac Surg; 2020; 31(8):e793-e796. PubMed ID: 33136914
[TBL] [Abstract][Full Text] [Related]
12. Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.
Aggarwal S; Singh M; Modi P; Walia E; Aggarwal R
Oral Maxillofac Surg; 2017 Dec; 21(4):383-390. PubMed ID: 28785906
[TBL] [Abstract][Full Text] [Related]
13. [Retromandibular incision and miniplate rigid fixation for condylar and subcondylar fractures].
Wu CY; Shi XJ; Li Y
Shanghai Kou Qiang Yi Xue; 2004 Feb; 13(1):20-2. PubMed ID: 15007474
[TBL] [Abstract][Full Text] [Related]
14. Comparative biomechanical study on three miniplates osteosynthesis systems for stabilisation of low condylar fractures of the mandible.
Hakim SG; Wolf M; Wendlandt R; Kimmerle H; Sieg P; Jacobsen HC
Br J Oral Maxillofac Surg; 2014 Apr; 52(4):317-22. PubMed ID: 24629455
[TBL] [Abstract][Full Text] [Related]
15. [Treatment of condylar fractures by anatomic reduction and rigid fixation with mini-plates].
Zhang Y; Zhang X
Zhonghua Kou Qiang Yi Xue Za Zhi; 2001 Mar; 36(2):99-101. PubMed ID: 11812314
[TBL] [Abstract][Full Text] [Related]
16. Which fixation methods are better between three-dimensional anatomical plate and two miniplates for the mandibular subcondylar fracture open treatment?
Sukegawa S; Kanno T; Masui M; Sukegawa-Takahashi Y; Kishimoto T; Sato A; Furuki Y
J Craniomaxillofac Surg; 2019 May; 47(5):771-777. PubMed ID: 30770259
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical study of the Delta plate and the TriLock Delta condyle trauma plate.
Haim D; Müller A; Leonhardt H; Nowak A; Richter G; Lauer G
J Oral Maxillofac Surg; 2011 Oct; 69(10):2619-25. PubMed ID: 21474224
[TBL] [Abstract][Full Text] [Related]
18. Efficacy of Delta Plate in Condylar Fracture: a Case Series with Review.
Sarkar A; Banerjee L; Ghosh S
J Dent (Shiraz); 2023 Mar; 24(1):71-75. PubMed ID: 36864994
[TBL] [Abstract][Full Text] [Related]
19. Two miniplates versus 3-dimensional plate in the management of mandibular subcondylar fractures: a retrospective analysis.
Rai A; Jain A; Thukral R
Oral Maxillofac Surg; 2021 Dec; 25(4):457-461. PubMed ID: 33432472
[TBL] [Abstract][Full Text] [Related]
20. Z-shaped Miniplates vs Conventional Miniplates for Fixation of Mandibular Parasymphyseal Fractures.
Abdou Ata MAE; Marzook HAM; Tawfik MA; Elmissiry ZMA
J Contemp Dent Pract; 2023 Oct; 24(10):761-770. PubMed ID: 38152909
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]