These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests - detection of clinically significant interference. Perović A; Dolčić M Scand J Clin Lab Invest; 2019 May; 79(3):154-159. PubMed ID: 30767593 [TBL] [Abstract][Full Text] [Related]
23. Studies on in vitro hemolysis and utility of corrective formulas for reporting results on hemolyzed specimens. Lippi G; Avanzini P; Pavesi F; Bardi M; Ippolito L; Aloe R; Favaloro EJ Biochem Med (Zagreb); 2011; 21(3):297-305. PubMed ID: 22420244 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays. Ji JZ; Meng QH Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617 [TBL] [Abstract][Full Text] [Related]
25. Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer. Du Z; Liu J; Zhang H; Bao B; Zhao R; Jin Y J Clin Lab Anal; 2019 May; 33(4):e22856. PubMed ID: 30779463 [TBL] [Abstract][Full Text] [Related]
26. Analysis of preanalytical errors in a clinical chemistry laboratory: A 2-year study. Alcantara JC; Alharbi B; Almotairi Y; Alam MJ; Muddathir ARM; Alshaghdali K Medicine (Baltimore); 2022 Jul; 101(27):e29853. PubMed ID: 35801773 [TBL] [Abstract][Full Text] [Related]
27. [The hemolysis index as quality indicator for extra-laboratory part of preanalytical phase]. Moshkin AV Klin Lab Diagn; 2012 Nov; (11):63-4. PubMed ID: 23305024 [TBL] [Abstract][Full Text] [Related]
28. Multicenter evaluation of the hemolysis index in automated clinical chemistry systems. Lippi G; Luca Salvagno G; Blanckaert N; Giavarina D; Green S; Kitchen S; Palicka V; Vassault AJ; Plebani M Clin Chem Lab Med; 2009; 47(8):934-9. PubMed ID: 19548845 [TBL] [Abstract][Full Text] [Related]
29. [THE PERCENTAGE OF BLOOD SERUM TESTS WITH HEMOLYSIS IN DIFFERENT GROUPS OF PATIENTS]. Moshkin AV Klin Lab Diagn; 2015 Jun; 60(6):14-7. PubMed ID: 26466445 [TBL] [Abstract][Full Text] [Related]
31. Development and validation of a simple correction method for the measurement of neuron-specific enolase in hemolyzed serum samples. Lauwers M; Frikha A; Fage D; Duterme C; De Vos N; Cotton F; Wolff F Scand J Clin Lab Invest; 2022 Feb; 82(1):12-17. PubMed ID: 34878363 [TBL] [Abstract][Full Text] [Related]
33. Effects of the hemolytic index on the test results of a dry chemistry analyzer and a verification of the hemolytic interference threshold. Yang Q; Huang S; Han R; Lin B; Liu Q; Duan X; Ma Z; Zhang H; Shou H; Zhang S Ann Palliat Med; 2022 Apr; 11(4):1381-1390. PubMed ID: 35523746 [TBL] [Abstract][Full Text] [Related]
34. Validation of hemolysis index thresholds optimizes detection of clinically significant hemolysis. Goyal T; Schmotzer CL Am J Clin Pathol; 2015 Apr; 143(4):579-83. PubMed ID: 25780011 [TBL] [Abstract][Full Text] [Related]
35. A Reference chart for clinical biochemical tests of hemolyzed serum samples. Ni J; Zhu W; Wang Y; Wei X; Li J; Peng L; Zhang K; Bai B J Clin Lab Anal; 2021 Jan; 35(1):e23561. PubMed ID: 32881061 [TBL] [Abstract][Full Text] [Related]
36. What is the best wavelength for the measurement of hemolysis index? Ishiguro A; Nishioka M; Morishige A; Kawano R; Kobayashi T; Fujinaga A; Takagi F; Kogo T; Morikawa Y; Okayama N; Mizuno H; Aihara M; Suehiro Y; Yamasaki T Clin Chim Acta; 2020 Nov; 510():15-20. PubMed ID: 32621815 [TBL] [Abstract][Full Text] [Related]
37. Influence of In Vitro Hemolysis on 80 Different Laboratory Tests. Yanagisawa Y; Isobe K; Naito A; Ishijima M; Nanmoku T; Yamamoto T; Suzuki E; Kawakami Y Clin Lab; 2017 Feb; 63(2):219-226. PubMed ID: 28182357 [TBL] [Abstract][Full Text] [Related]
38. [Hemolysis interference on clinical chemistry tests analyzed on DxC 700 AU (Beckman Coulter®) and kaliemia rendering algorithm]. Sanandedji E; André J; Lienard A; Hentgen C; Barrans A Ann Biol Clin (Paris); 2022 Jun; 80(3):225-232. PubMed ID: 35796468 [TBL] [Abstract][Full Text] [Related]
39. Effect of interference from hemolysis, icterus and lipemia on routine pediatric clinical chemistry assays. Agarwal S; Vargas G; Nordstrom C; Tam E; Buffone GJ; Devaraj S Clin Chim Acta; 2015 Jan; 438():241-5. PubMed ID: 25128720 [TBL] [Abstract][Full Text] [Related]