These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 34637810)

  • 1. Virtual histology of an entire mouse brain from formalin fixation to paraffin embedding. Part 2: Volumetric strain fields and local contrast changes.
    Rodgers G; Tanner C; Schulz G; Migga A; Kuo W; Bikis C; Scheel M; Kurtcuoglu V; Weitkamp T; Müller B
    J Neurosci Methods; 2022 Jan; 365():109385. PubMed ID: 34637810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Virtual histology of an entire mouse brain from formalin fixation to paraffin embedding. Part 1: Data acquisition, anatomical feature segmentation, tracking global volume and density changes.
    Rodgers G; Kuo W; Schulz G; Scheel M; Migga A; Bikis C; Tanner C; Kurtcuoglu V; Weitkamp T; Müller B
    J Neurosci Methods; 2021 Dec; 364():109354. PubMed ID: 34529981
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extending two-dimensional histology into the third dimension through conventional micro computed tomography.
    Khimchenko A; Deyhle H; Schulz G; Schweighauser G; Hench J; Chicherova N; Bikis C; Hieber SE; Müller B
    Neuroimage; 2016 Oct; 139():26-36. PubMed ID: 27321044
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The spatiotemporal spread of cervical spinal cord contusion injury pathology revealed by 3D in-line phase contrast synchrotron X-ray microtomography.
    Strotton MC; Bodey AJ; Wanelik K; Hobbs C; Rau C; Bradbury EJ
    Exp Neurol; 2021 Feb; 336():113529. PubMed ID: 33220238
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contrast enhancement for visualizing neuronal cytoarchitecture by propagation-based x-ray phase-contrast tomography.
    Töpperwien M; Markus A; Alves F; Salditt T
    Neuroimage; 2019 Oct; 199():70-80. PubMed ID: 31129306
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Synchrotron inline phase contrast µCT enables detailed virtual histology of embedded soft-tissue samples with and without staining.
    Saccomano M; Albers J; Tromba G; Dobrivojević Radmilović M; Gajović S; Alves F; Dullin C
    J Synchrotron Radiat; 2018 Jul; 25(Pt 4):1153-1161. PubMed ID: 29979177
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Establishing sample-preparation protocols for X-ray phase-contrast CT of rodent spinal cords: Aldehyde fixations and osmium impregnation.
    Barbone GE; Bravin A; Mittone A; Kraiger MJ; Hrabě de Angelis M; Bossi M; Ballarini E; Rodriguez-Menendez V; Ceresa C; Cavaletti G; Coan P
    J Neurosci Methods; 2020 Jun; 339():108744. PubMed ID: 32353471
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three dimensional imaging of paraffin embedded human lung tissue samples by micro-computed tomography.
    Scott AE; Vasilescu DM; Seal KA; Keyes SD; Mavrogordato MN; Hogg JC; Sinclair I; Warner JA; Hackett TL; Lackie PM
    PLoS One; 2015; 10(6):e0126230. PubMed ID: 26030902
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sub-micrometer morphology of human atherosclerotic plaque revealed by synchrotron radiation-based μCT-A comparison with histology.
    Truong M; Dreier T; Wassélius J; Sundius L; Persson A; Lovric G; Bonnin A; Goncalves I; Bech M
    PLoS One; 2022; 17(4):e0265598. PubMed ID: 35471989
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparation of large biological samples for high-resolution, hierarchical, synchrotron phase-contrast tomography with multimodal imaging compatibility.
    Brunet J; Walsh CL; Wagner WL; Bellier A; Werlein C; Marussi S; Jonigk DD; Verleden SE; Ackermann M; Lee PD; Tafforeau P
    Nat Protoc; 2023 May; 18(5):1441-1461. PubMed ID: 36859614
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An optimized workflow for microCT imaging of formalin-fixed and paraffin-embedded (FFPE) early equine embryos.
    Handschuh S; Okada CTC; Walter I; Aurich C; Glösmann M
    Anat Histol Embryol; 2022 Sep; 51(5):611-623. PubMed ID: 35851500
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR microscopy of formalin fixed paraffin embedded histology specimens.
    Macura S; Mishra PK; Gamez JD; Pirko I
    Magn Reson Med; 2014 Jun; 71(6):1989-94. PubMed ID: 24715442
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The choice of embedding media affects image quality, tissue R
    Dusek P; Madai VI; Huelnhagen T; Bahn E; Matej R; Sobesky J; Niendorf T; Acosta-Cabronero J; Wuerfel J
    Magn Reson Med; 2019 Apr; 81(4):2688-2701. PubMed ID: 30506939
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative analysis of fixation and embedding techniques for optimized histological preparation of zebrafish.
    Copper JE; Budgeon LR; Foutz CA; van Rossum DB; Vanselow DJ; Hubley MJ; Clark DP; Mandrell DT; Cheng KC
    Comp Biochem Physiol C Toxicol Pharmacol; 2018 Jun; 208():38-46. PubMed ID: 29157956
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Human lung virtual histology by multi-scale x-ray phase-contrast computed tomography.
    Reichmann J; Verleden SE; Kühnel M; Kamp JC; Werlein C; Neubert L; Müller JH; Bui TQ; Ackermann M; Jonigk D; Salditt T
    Phys Med Biol; 2023 May; 68(11):. PubMed ID: 37167977
    [No Abstract]   [Full Text] [Related]  

  • 16. Synchrotron X-ray micro-CT as a validation dataset for diffusion MRI in whole mouse brain.
    Trinkle S; Foxley S; Kasthuri N; La Rivière P
    Magn Reson Med; 2021 Aug; 86(2):1067-1076. PubMed ID: 33768633
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Imaging of articular cartilage--data matching using X-ray tomography, SEM, FIB slicing and conventional histology.
    Zehbe R; Riesemeier H; Kirkpatrick CJ; Brochhausen C
    Micron; 2012 Oct; 43(10):1060-7. PubMed ID: 22633854
    [TBL] [Abstract][Full Text] [Related]  

  • 18. μCT of ex-vivo stained mouse hearts and embryos enables a precise match between 3D virtual histology, classical histology and immunochemistry.
    Dullin C; Ufartes R; Larsson E; Martin S; Lazzarini M; Tromba G; Missbach-Guentner J; Pinkert-Leetsch D; Katschinski DM; Alves F
    PLoS One; 2017; 12(2):e0170597. PubMed ID: 28178293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Virtual histology uncertainty in synchrotron x-ray micro-computed tomography evaluation.
    Lauridsen T; Feidenhans'l R; Pinholt EM
    J Craniomaxillofac Surg; 2018 Sep; 46(9):1569-1575. PubMed ID: 30098873
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MicroCT-based virtual histology evaluation of preclinical medulloblastoma.
    Prajapati SI; Kilcoyne A; Samano AK; Green DP; McCarthy SD; Blackman BA; Brady MM; Zarzabal LA; Tatiparthi AK; Sledz TJ; Duong T; Ohshima-Hosoyama S; Giles FJ; Michalek JE; Rubin BP; Keller C
    Mol Imaging Biol; 2011 Jun; 13(3):493-499. PubMed ID: 20617390
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.