These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 34643065)

  • 1. Early experience with MR-guided adaptive radiotherapy using a 1.5 T MR-Linac: First 6 months of operation using adapt to shape workflow.
    de Leon J; Crawford D; Moutrie Z; Alvares S; Hogan L; Pagulayan C; Jelen U; Loo C; Aylward JD; Condon K; Dunkerley N; Heinke MY; Sampaio S; Simon K; Twentyman T; Jameson MG
    J Med Imaging Radiat Oncol; 2022 Feb; 66(1):138-145. PubMed ID: 34643065
    [TBL] [Abstract][Full Text] [Related]  

  • 2. First Experience and Prospective Evaluation on Feasibility and Acute Toxicity of Online Adaptive Radiotherapy of the Prostate Bed as Salvage Treatment in Patients with Biochemically Recurrent Prostate Cancer on a 1.5T MR-Linac.
    Wegener D; Thome A; Paulsen F; Gani C; Boldt J; Butzer S; Thorwarth D; Moennich D; Nachbar M; Müller AC; Zips D; Boeke S
    J Clin Med; 2022 Aug; 11(16):. PubMed ID: 36012885
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Brain stereotactic radiosurgery using MR-guided online adaptive planning for daily setup variation: An end-to-end test.
    Han EY; Wang H; Briere TM; Yeboa DN; Boursianis T; Kalaitzakis G; Pappas E; Castillo P; Yang J
    J Appl Clin Med Phys; 2022 Mar; 23(3):e13518. PubMed ID: 34994101
    [TBL] [Abstract][Full Text] [Related]  

  • 4. End-to-end validation of the geometric dose delivery performance of MR linac adaptive radiotherapy.
    Bernchou U; Christiansen RL; Bertelsen A; Tilly D; Riis HL; Jensen HR; Mahmood F; Hansen CR; Hansen VN; Schytte T; Brink C
    Phys Med Biol; 2021 Feb; 66(4):045034. PubMed ID: 33321475
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic resonance guided adaptive post prostatectomy radiotherapy: Accumulated dose comparison of different workflows.
    Hassan SP; de Leon J; Batumalai V; Moutrie Z; Hogan L; Ge Y; Stricker P; Jameson MG
    J Appl Clin Med Phys; 2024 Apr; 25(4):e14253. PubMed ID: 38394627
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Online Adaptive MR-Guided Ultrahypofractionated Radiotherapy of Prostate Cancer on a 1.5 T MR-Linac: Clinical Experience and Prospective Evaluation.
    Potkrajcic V; Gani C; Fischer SG; Boeke S; Niyazi M; Thorwarth D; Voigt O; Schneider M; Mönnich D; Kübler S; Boldt J; Hoffmann E; Paulsen F; Mueller AC; Wegener D
    Curr Oncol; 2024 May; 31(5):2679-2688. PubMed ID: 38785484
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Therapeutic Radiographers at the Helm: Moving Towards Radiographer-Led MR-Guided Radiotherapy.
    Hales RB; Rodgers J; Whiteside L; McDaid L; Berresford J; Budgell G; Choudhury A; Eccles CL
    J Med Imaging Radiat Sci; 2020 Sep; 51(3):364-372. PubMed ID: 32600981
    [TBL] [Abstract][Full Text] [Related]  

  • 8. First clinical experiences with a high field 1.5 T MR linac.
    Bertelsen AS; Schytte T; Møller PK; Mahmood F; Riis HL; Gottlieb KL; Agergaard SN; Dysager L; Hansen O; Gornitzka J; Veldhuizen E; ODwyer DB; Christiansen RL; Nielsen M; Jensen HR; Brink C; Bernchou U
    Acta Oncol; 2019 Oct; 58(10):1352-1357. PubMed ID: 31241387
    [No Abstract]   [Full Text] [Related]  

  • 9. Dosimetric comparison of MR-linac-based IMRT and conventional VMAT treatment plans for prostate cancer.
    Da Silva Mendes V; Nierer L; Li M; Corradini S; Reiner M; Kamp F; Niyazi M; Kurz C; Landry G; Belka C
    Radiat Oncol; 2021 Jul; 16(1):133. PubMed ID: 34289868
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 4D-MRI driven MR-guided online adaptive radiotherapy for abdominal stereotactic body radiation therapy on a high field MR-Linac: Implementation and initial clinical experience.
    Paulson ES; Ahunbay E; Chen X; Mickevicius NJ; Chen GP; Schultz C; Erickson B; Straza M; Hall WA; Li XA
    Clin Transl Radiat Oncol; 2020 Jul; 23():72-79. PubMed ID: 32490218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High grade glioma radiation therapy on a high field 1.5 Tesla MR-Linac - workflow and initial experience with daily adapt-to-position (ATP) MR guidance: A first report.
    Tseng CL; Chen H; Stewart J; Lau AZ; Chan RW; Lawrence LSP; Myrehaug S; Soliman H; Detsky J; Lim-Fat MJ; Lipsman N; Das S; Heyn C; Maralani PJ; Binda S; Perry J; Keller B; Stanisz GJ; Ruschin M; Sahgal A
    Front Oncol; 2022; 12():1060098. PubMed ID: 36518316
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An unusual case of oedematous prostate volumetric changes observed over the course of radiotherapy on the MR linear accelerator.
    Clough A; Bridge P; Hales R; McDaid L; Choudhury A; Eccles CL
    J Med Imaging Radiat Sci; 2021 Mar; 52(1):147-151. PubMed ID: 33342695
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new workflow of the on-line 1.5-T MR-guided adaptive radiation therapy.
    Uno T; Tsuneda M; Abe K; Fujita Y; Harada R; Saito M; Kanazawa A; Kodate A; Abe Y; Ikeda Y; Nemoto MW; Yokota H
    Jpn J Radiol; 2023 Nov; 41(11):1316-1322. PubMed ID: 37354344
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical Implementation and Initial Experience With a 1.5 Tesla MR-Linac for MR-Guided Radiation Therapy for Gynecologic Cancer: An R-IDEAL Stage 1 and 2a First in Humans Feasibility Study of New Technology Implementation.
    Lakomy DS; Yang J; Vedam S; Wang J; Lee B; Sobremonte A; Castillo P; Hughes N; Mohammedsaid M; Jhingran A; Klopp AH; Choi S; Fuller CD; Lin LL
    Pract Radiat Oncol; 2022; 12(4):e296-e305. PubMed ID: 35278717
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac.
    Chen X; Ahunbay E; Paulson ES; Chen G; Li XA
    J Appl Clin Med Phys; 2020 Jan; 21(1):205-212. PubMed ID: 31799753
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI-guided linac and comparison vs a C-arm-mounted linac.
    Slagowski JM; Redler G; Malin MJ; Cammin J; Lobb EC; Lee BH; Sethi A; Roeske JC; Flores-Martinez E; Stevens T; Yenice KM; Green O; Mutic S; Aydogan B
    Med Phys; 2020 Nov; 47(11):5455-5466. PubMed ID: 32996591
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Online adaptive MR-guided radiotherapy for rectal cancer; feasibility of the workflow on a 1.5T MR-linac: clinical implementation and initial experience.
    Intven MPW; de Mol van Otterloo SR; Mook S; Doornaert PAH; de Groot-van Breugel EN; Sikkes GG; Willemsen-Bosman ME; van Zijp HM; Tijssen RHN
    Radiother Oncol; 2021 Jan; 154():172-178. PubMed ID: 32976875
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a 4D-MRI guided liver stereotactic body radiation therapy strategy for implementation on the MR-linac.
    van de Lindt TN; Fast MF; van den Wollenberg W; Kaas J; Betgen A; Nowee ME; Jansen EP; Schneider C; van der Heide UA; Sonke JJ
    Phys Med Biol; 2021 May; 66(10):. PubMed ID: 33887708
    [No Abstract]   [Full Text] [Related]  

  • 19. Technical Note: End-to-end verification of an MR-Linac using a dynamic motion phantom.
    Liu X; Li C; Zhu J; Gong G; Sun H; Li X; Sun M; Zhang Z; Li B; Yin Y; Li Z
    Med Phys; 2021 Sep; 48(9):5479-5489. PubMed ID: 34174099
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First 500 Fractions Delivered with a Magnetic Resonance-guided Radiotherapy System: Initial Experience.
    Sahin B; Zoto Mustafayev T; Gungor G; Aydin G; Yapici B; Atalar B; Ozyar E
    Cureus; 2019 Dec; 11(12):e6457. PubMed ID: 32025388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.