BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

290 related articles for article (PubMed ID: 34655249)

  • 1. Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases.
    Cui T; Zhou Y; Yue NJ; Vergalasova I; Zhang Y; Zhu J; Nie K
    Med Phys; 2021 Dec; 48(12):7632-7640. PubMed ID: 34655249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery.
    Nakano H; Tanabe S; Sasamoto R; Takizawa T; Utsunomiya S; Sakai M; Nakano T; Ohta A; Kaidu M; Ishikawa H
    J Appl Clin Med Phys; 2021 Jul; 22(7):266-275. PubMed ID: 34151498
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases.
    Nakano H; Tanabe S; Utsunomiya S; Yamada T; Sasamoto R; Nakano T; Saito H; Takizawa T; Sakai H; Ohta A; Abe E; Kaidu M; Aoyama H
    J Appl Clin Med Phys; 2020 Dec; 21(12):155-165. PubMed ID: 33119953
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heuristic knowledge-based planning for single-isocenter stereotactic radiosurgery to multiple brain metastases.
    Ziemer BP; Sanghvi P; Hattangadi-Gluth J; Moore KL
    Med Phys; 2017 Oct; 44(10):5001-5009. PubMed ID: 28731267
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis.
    Nakano H; Tanabe S; Yamada T; Utsunomiya S; Takizawa T; Sakai M; Sasamoto R; Sakai H; Nakano T; Saito H; Ohta A; Kaidu M; Ishikawa H
    Radiol Phys Technol; 2021 Mar; 14(1):57-63. PubMed ID: 33393057
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of dosimetric impact of intra-fractional setup discrepancy between multiple- and single-isocenter approaches in linac-based stereotactic radiotherapy of multiple brain metastases.
    Tsui SSW; Wu VWC; Cheung JSC
    J Appl Clin Med Phys; 2022 Feb; 23(2):e13484. PubMed ID: 34931447
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Predicting the effect of indirect cell kill in the treatment of multiple brain metastases via single-isocenter/multitarget volumetric modulated arc therapy stereotactic radiosurgery.
    Palmiero AN; Fabian D; Randall ME; Clair W; Pokhrel D
    J Appl Clin Med Phys; 2021 Oct; 22(10):94-103. PubMed ID: 34498359
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Innovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery.
    Yock AD; Grees B; Luo G
    Phys Med Biol; 2023 Sep; 68(19):. PubMed ID: 37673075
    [No Abstract]   [Full Text] [Related]  

  • 9. Optimization of isocenter position for multiple brain metastases single-isocenter stereotactic radiosurgery to minimize dosimetric variations due to rotational uncertainty.
    Shen Z; Wang H; Shao Y; Duan Y; Gu H; Chen H; Feng A; Huang Y; Xu Z
    Phys Med; 2023 Jul; 111():102614. PubMed ID: 37295129
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume.
    Slagowski JM; Wen Z
    Phys Med Biol; 2020 Sep; 65(18):185012. PubMed ID: 32460254
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques.
    Prentou G; Pappas EP; Logothetis A; Koutsouveli E; Pantelis E; Papagiannis P; Karaiskos P
    J Appl Clin Med Phys; 2020 Mar; 21(3):32-44. PubMed ID: 32022447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique.
    Ruggieri R; Naccarato S; Mazzola R; Ricchetti F; Corradini S; Fiorentino A; Alongi F
    Radiat Oncol; 2018 Mar; 13(1):38. PubMed ID: 29506539
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Management of multiple brain metastases via dual-isocenter VMAT stereotactic radiosurgery.
    Palmiero AN; Fabian D; St Clair W; Randall M; Pokhrel D
    Med Dosim; 2021 Autumn; 46(3):240-246. PubMed ID: 33549397
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An Extremely Inhomogeneous Gross Tumor Dose is Suitable for Volumetric Modulated Arc-Based Radiosurgery with a 5-mm Leaf-Width Multileaf Collimator for Single Brain Metastasis.
    Ohtakara K; Suzuki K
    Cureus; 2023 Feb; 15(2):e35467. PubMed ID: 36999102
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI-guided linac and comparison vs a C-arm-mounted linac.
    Slagowski JM; Redler G; Malin MJ; Cammin J; Lobb EC; Lee BH; Sethi A; Roeske JC; Flores-Martinez E; Stevens T; Yenice KM; Green O; Mutic S; Aydogan B
    Med Phys; 2020 Nov; 47(11):5455-5466. PubMed ID: 32996591
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Proposal of an Alternative Near-Minimum Isodose Surface DV-0.01 cc Equally Minimizing Gross Tumor Volume Below the Relevant Dose as the Basis for Dose Prescription and Evaluation of Stereotactic Radiosurgery for Brain Metastases.
    Ohtakara K; Suzuki K
    Cureus; 2024 Apr; 16(4):e57580. PubMed ID: 38707120
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Single-Isocenter Volumetric Modulated Arc Therapy (VMAT) Radiosurgery for Multiple Brain Metastases: Potential Loss of Target(s) Coverage Due to Isocenter Misalignment.
    Palmiero AN; Critchfield L; St Clair W; Randall M; Pokhrel D
    Cureus; 2020 Oct; 12(10):e11267. PubMed ID: 33274143
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single-isocenter stereotactic radiosurgery for multiple brain metastases: Impact of patient misalignments on target coverage in non-coplanar treatments.
    Eder MM; Reiner M; Heinz C; Garny S; Freislederer P; Landry G; Niyazi M; Belka C; Riboldi M
    Z Med Phys; 2022 Aug; 32(3):296-311. PubMed ID: 35504799
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric Study of Automatic Brain Metastases Planning in Comparison with Conventional Multi-Isocenter Dynamic Conformal Arc Therapy and Gamma Knife Radiosurgery for Multiple Brain Metastases.
    Mori Y; Kaneda N; Hagiwara M; Ishiguchi T
    Cureus; 2016 Nov; 8(11):e882. PubMed ID: 28003946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Restricted single isocenter for multiple targets dynamic conformal arc (RSIMT DCA) technique for brain stereotactic radiosurgery (SRS) planning.
    Chang J; Wernicke AG; Pannullo SC
    J Radiosurg SBRT; 2018; 5(2):145-156. PubMed ID: 29657895
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.