41. Analysis of P50 and oxygen transport in patients after cardiac surgery. Oudemans-van Straaten HM; Scheffer GJ; Stoutenbeek CP Intensive Care Med; 1996 Aug; 22(8):781-9. PubMed ID: 8880247 [TBL] [Abstract][Full Text] [Related]
42. The influence of cardiopulmonary by-pass on respiratory function in patients who underwent coronary disease surgery. Krdzalic A; Klokocovnik T; Krdzalic G; Gaco S Med Arch; 2013; 67(2):97-100. PubMed ID: 24341053 [TBL] [Abstract][Full Text] [Related]
43. Continuous venous oximetry during cardiopulmonary bypass: influence of temperature changes, perfusion flow, and hematocrit levels. Baraka A; Baroody M; Haroun S; Nawfal M; Dabbous A; Sibai A; Jamal S; Shamli S J Cardiothorac Anesth; 1990 Feb; 4(1):35-8. PubMed ID: 2131853 [TBL] [Abstract][Full Text] [Related]
44. Relation between mixed venous oxygen saturation and cardiac index. Nonlinearity and normalization for oxygen uptake and hemoglobin. Jain A; Shroff SG; Janicki JS; Reddy HK; Weber KT Chest; 1991 Jun; 99(6):1403-9. PubMed ID: 1828020 [TBL] [Abstract][Full Text] [Related]
45. Is body surface area still the best way to determine pump flow rate during cardiopulmonary bypass? Alston RP; Anderson A; Sanger K Perfusion; 2006 May; 21(3):139-47. PubMed ID: 16817286 [TBL] [Abstract][Full Text] [Related]
46. [Continuous monitoring of hemoglobin oxygen saturation in mixed venous blood during thoracic anesthesia with selective single-lung ventilation]. Herrera A; Pajeulo A; Morano MJ; Ureta MP; Ruiz A; de las Mulas M Rev Esp Anestesiol Reanim; 1993; 40(5):258-67. PubMed ID: 8248605 [TBL] [Abstract][Full Text] [Related]
47. Effect of changes in inspired oxygen fraction on oxygen delivery during cardiac surgery: a substudy of the CARROT trial. Nam K; Kim HB; Kwak YL; Jeong YH; Ju JW; Bae J; Lee S; Cho YJ; Shim JK; Jeon Y Sci Rep; 2021 Sep; 11(1):17862. PubMed ID: 34504252 [TBL] [Abstract][Full Text] [Related]
49. Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery. De Rosa RC; Romano GM; Abbate R; Corcione A; De Robertis E J Clin Monit Comput; 2020 Jun; 34(3):501-508. PubMed ID: 31183770 [TBL] [Abstract][Full Text] [Related]
50. Accuracy, Precision, and Trending Ability of Perioperative Central Venous Oxygen Saturation Compared to Mixed Venous Oxygen Saturation in Unselected Cardiac Surgical Patients. Lanning KM; Erkinaro TM; Ohtonen PP; Vakkala MA; Liisanantti JH; Ylikauma LA; Kaakinen TI J Cardiothorac Vasc Anesth; 2022 Jul; 36(7):1995-2001. PubMed ID: 34593310 [TBL] [Abstract][Full Text] [Related]
51. Increasing mean arterial blood pressure has no effect on jugular venous oxygen saturation in insulin-dependent patients during tepid cardiopulmonary bypass. Kadoi Y; Saito S; Yoshikawa D; Goto F; Fujita N; Kunimoto F Anesth Analg; 2002 Aug; 95(2):266-72, table of contents. PubMed ID: 12145032 [TBL] [Abstract][Full Text] [Related]
52. The effect of perfusion flow on oxidative metabolism during cardiopulmonary bypass. Baraka A Anesth Analg; 1993 Jun; 76(6):1191-4. PubMed ID: 8498653 [TBL] [Abstract][Full Text] [Related]
53. Mixed venous oxygen saturation during mobilization after cardiac surgery: are reflectance oximetry catheters reliable? Kirkeby-Garstad I; Skogvoll E; Sellevold FM Acta Anaesthesiol Scand; 2000 Oct; 44(9):1103-8. PubMed ID: 11028731 [TBL] [Abstract][Full Text] [Related]
55. Comparison of Mixed Venous Oxygen Saturation and Premembranous Venous Oxygen Saturation in Patients on Peripheral Venous-Arterial Extracorporeal Membrane Oxygenation. John KJ; Belani DJ; Kapur NK; Lussier L; Chweich H ASAIO J; 2024 Mar; ():. PubMed ID: 38513112 [TBL] [Abstract][Full Text] [Related]
56. Analytical performance evaluation of four cartridge-type blood gas analyzers. De Koninck AS; De Decker K; Van Bocxlaer J; Meeus P; Van Hoovels L Clin Chem Lab Med; 2012 Feb; 50(6):1083-91. PubMed ID: 22706251 [TBL] [Abstract][Full Text] [Related]
57. Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators. Minami K; Bairaktaris A; Murray E; Weitkemper H; Dramburg W; Körfer R J Cardiovasc Surg (Torino); 1997 Jun; 38(3):227-32. PubMed ID: 9219471 [TBL] [Abstract][Full Text] [Related]
58. Transfusion policy in pediatric extracorporeal membrane oxygenation patients: Less could be more. Duarte CM; Lopes MI; Abecasis F Perfusion; 2024 Jan; 39(1):96-105. PubMed ID: 35634987 [TBL] [Abstract][Full Text] [Related]
59. Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock. Varpula M; Karlsson S; Ruokonen E; Pettilä V Intensive Care Med; 2006 Sep; 32(9):1336-43. PubMed ID: 16826387 [TBL] [Abstract][Full Text] [Related]