These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
156 related articles for article (PubMed ID: 34666026)
1. Setting analytical performance specifications using HbA1c as a model measurand. Loh TP; Smith AF; Bell KJL; Lord SJ; Ceriotti F; Jones G; Bossuyt P; Sandberg S; Horvath AR Clin Chim Acta; 2021 Dec; 523():407-414. PubMed ID: 34666026 [TBL] [Abstract][Full Text] [Related]
2. Analytical performance specifications for external quality assessment - definitions and descriptions. Jones GRD; Albarede S; Kesseler D; MacKenzie F; Mammen J; Pedersen M; Stavelin A; Thelen M; Thomas A; Twomey PJ; Ventura E; Panteghini M; Clin Chem Lab Med; 2017 Jun; 55(7):949-955. PubMed ID: 28593915 [TBL] [Abstract][Full Text] [Related]
3. Verification of point-of-care analysers for C-reactive protein, lipid studies and glycated haemoglobin. Li B; Kumar A; Finlay C; van Drimmelen M; Barnes E; Southby S; Florkowski C Pathology; 2023 Dec; 55(7):989-999. PubMed ID: 37778963 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of HbA1c as Monitored by External Quality Assessment and Compared With Patient Mean Values. Nordin G J Diabetes Sci Technol; 2018 Jul; 12(4):771-779. PubMed ID: 29916732 [TBL] [Abstract][Full Text] [Related]
6. Performance specifications for measurement uncertainty of common biochemical measurands according to Milan models. Braga F; Panteghini M Clin Chem Lab Med; 2021 Mar; ():. PubMed ID: 33725754 [TBL] [Abstract][Full Text] [Related]
7. APS calculator: a data-driven tool for setting outcome-based analytical performance specifications for measurement uncertainty using specific clinical requirements and population data. Çubukçu HC; Vanstapel F; Thelen M; van Schrojenstein Lantman M; Bernabeu-Andreu FA; Meško Brguljan P; Milinkovic N; Linko S; Panteghini M; Boursier G Clin Chem Lab Med; 2024 Mar; 62(4):597-607. PubMed ID: 37978287 [TBL] [Abstract][Full Text] [Related]
8. How clinical laboratories select and use Analytical Performance Specifications (APS) in Italy. Ceriotti F; Buoro S; Pasotti F Clin Chem Lab Med; 2024 Jul; 62(8):1470-1473. PubMed ID: 38411177 [TBL] [Abstract][Full Text] [Related]
9. National continuous surveys on internal quality control for HbA1c in 306 clinical laboratories of China from 2012 to 2016: Continual improvement. Li T; Wang W; Zhao H; He F; Zhong K; Yuan S; Wang Z J Clin Lab Anal; 2017 Sep; 31(5):. PubMed ID: 27868236 [TBL] [Abstract][Full Text] [Related]
10. Outcome-based analytical performance specifications: current status and future challenges. Horvath AR; Bell KJL; Ceriotti F; Jones GRD; Loh TP; Lord S; Sandberg S; Clin Chem Lab Med; 2024 Jul; 62(8):1474-1482. PubMed ID: 38836433 [TBL] [Abstract][Full Text] [Related]
11. Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference. Ceriotti F; Fernandez-Calle P; Klee GG; Nordin G; Sandberg S; Streichert T; Vives-Corrons JL; Panteghini M Clin Chem Lab Med; 2017 Feb; 55(2):189-194. PubMed ID: 27506603 [TBL] [Abstract][Full Text] [Related]
12. Using analytical performance specifications in a medical laboratory. Jones GRD Clin Chem Lab Med; 2024 Jul; 62(8):1512-1519. PubMed ID: 38624006 [TBL] [Abstract][Full Text] [Related]
13. Consequences of bias and imprecision in measurements of glucose and hba1c for the diagnosis and prognosis of diabetes mellitus. Petersen PH; Jørgensen LG; Brandslund I; De Fine Olivarius N; Stahl M Scand J Clin Lab Invest Suppl; 2005; 240():51-60. PubMed ID: 16112960 [TBL] [Abstract][Full Text] [Related]
14. Performance evaluation of HbA1c measurement systems with sigma metric for 1066 laboratories in China. Huang Y; Zhang T; Zhao H; Wang W; Zhang C; He F; Zhong K; Yuan S; Du Y; Wang Z Clin Chim Acta; 2018 Dec; 487():281-286. PubMed ID: 30312599 [TBL] [Abstract][Full Text] [Related]
15. Analytical performance specifications based on the state-of-the-art for the newborn screening. Guiñón L; Soler A; Molina A; Marín JL; López RM; García-Villoria J; Sahuquillo Á; Alvarez L Clin Chim Acta; 2020 Nov; 510():117-120. PubMed ID: 32652162 [TBL] [Abstract][Full Text] [Related]
16. Application of biological variation and sigma metrics to evaluate the performance of HbA Kang F; Li W; Lou Y; Shan Z Scand J Clin Lab Invest; 2022 Sep; 82(5):398-403. PubMed ID: 35872643 [TBL] [Abstract][Full Text] [Related]
17. Setting analytical performance specifications based on outcome studies - is it possible? Horvath AR; Bossuyt PM; Sandberg S; John AS; Monaghan PJ; Verhagen-Kamerbeek WD; Lennartz L; Cobbaert CM; Ebert C; Lord SJ; Clin Chem Lab Med; 2015 May; 53(6):841-8. PubMed ID: 25996384 [TBL] [Abstract][Full Text] [Related]
18. Applying the Milan models to setting analytical performance specifications - considering all the information. Jones GRD; Bell KJL; Ceriotti F; Loh TP; Lord S; Sandberg S; Smith AF; Horvath AR Clin Chem Lab Med; 2024 Jul; 62(8):1531-1537. PubMed ID: 38801089 [TBL] [Abstract][Full Text] [Related]
19. Trueness assessment of HbA1c routine assays: are processed EQA materials up to the job? Delatour V; Clouet-Foraison N; Jaisson S; Kaiser P; Gillery P Clin Chem Lab Med; 2019 Sep; 57(10):1623-1631. PubMed ID: 31085744 [TBL] [Abstract][Full Text] [Related]
20. Assessing quality on the Sigma scale from proficiency testing and external quality assessment surveys. Westgard JO; Westgard SA Clin Chem Lab Med; 2015 Sep; 53(10):1531-5. PubMed ID: 25719323 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]