BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 34670477)

  • 1. Characteristics of bioimpedance-determined fluid shifts according to intradialytic blood pressure difference.
    Kwon YE; Choi HM; Oh DJ
    Ren Fail; 2021 Dec; 43(1):1446-1453. PubMed ID: 34670477
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationship between volume status and blood pressure during chronic hemodialysis.
    Leypoldt JK; Cheung AK; Delmez JA; Gassman JJ; Levin NW; Lewis JA; Lewis JL; Rocco MV
    Kidney Int; 2002 Jan; 61(1):266-75. PubMed ID: 11786109
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The source of net ultrafiltration during hemodialysis is mostly the extracellular space regardless of hydration status.
    Jeong H; Lim CW; Choi HM; Oh DJ
    Hemodial Int; 2016 Jan; 20(1):129-33. PubMed ID: 26046949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessing Extracellular Volume in Hemodialysis Patients Using Intradialytic Blood Pressure Slopes.
    Liu H; Lu R; Shastri S; Sonderman M; Van Buren PN
    Nephron; 2018; 139(2):120-130. PubMed ID: 29439257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of dialysis sodium gradient on intradialytic hypertension: an observational study.
    Movilli E; Camerini C; Gaggia P; Zubani R; Feller P; Poiatti P; Pola A; Carli O; Valzorio B; Cancarini G
    Am J Nephrol; 2013; 38(5):413-9. PubMed ID: 24216674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Association of Bioimpedance Parameters with Increases in Blood Pressure during Hemodialysis.
    Elsayed E; Farag YMK; Ravi KS; Chertow GM; Mc Causland FR
    Clin J Am Soc Nephrol; 2024 Mar; 19(3):329-335. PubMed ID: 37971865
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bioimpedance analysis and intradialytic hypotension in intermittent hemodialysis.
    Koziolek MJ; Gauczinski S; Kahler E; Bramlage CP; Scheel AK; Mueller GA; Strutz F
    Clin Nephrol; 2006 Jul; 66(1):39-50. PubMed ID: 16878434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Blood Pressure and Cognitive Decline in Prevalent Hemodialysis Patients.
    Drew DA; Tighiouart H; Duncan S; Rollins J; Gupta A; Scott T; Weiner DE; Sarnak MJ
    Am J Nephrol; 2019; 49(6):460-469. PubMed ID: 31048586
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf.
    Zhu F; Kuhlmann MK; Sarkar S; Kaitwatcharachai C; Khilnani R; Leonard EF; Greenwood R; Levin NW
    Int J Artif Organs; 2004 Feb; 27(2):104-9. PubMed ID: 15061473
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Relationship between fluid status as assessed by bioimpedance analysis and NT-pro BNP, blood pressure and left ventricular mass index in hemodialysis patients.
    Yilmaz Z; Yildirim Y; Aydin FY; Aydin E; Kadiroglu AK; Yilmaz ME; Ulgen MS; Yildiz A
    Clin Ter; 2014; 165(1):e52-8. PubMed ID: 24589961
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of ultrafiltration on peripheral urea sequestration in haemodialysis patients.
    Schneditz D; Zaluska WT; Morris AT; Levin NW
    Nephrol Dial Transplant; 2001 May; 16(5):994-8. PubMed ID: 11328906
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-invasive method for preventing intradialytic hypotension: A pilot study.
    Saxena A; Sharma RK; Gupta A; John MM
    Saudi J Kidney Dis Transpl; 2015 Sep; 26(5):896-905. PubMed ID: 26354560
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of Change in Fluid Status Evaluated by Bioimpedance Techniques on Body Composition in Hemodialysis Patients.
    Abbas SR; Thijssen S; Penne EL; Raimann JG; Liu L; Sipahioglu MH; Seibert E; Wang Y; Chen Y; Xiao Q; Levin NW; Kotanko P; Zhu F
    J Ren Nutr; 2018 May; 28(3):183-190. PubMed ID: 29158062
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Forecast post-dialysis blood pressure in hemodialysis patients with intradialytic hypertension.
    Zou LX; Sun L
    Clin Exp Hypertens; 2019; 41(6):571-576. PubMed ID: 30325241
    [No Abstract]   [Full Text] [Related]  

  • 15. Effects of short daily hemodialysis and extended standard hemodialysis on blood pressure and cardiac hypertrophy: a comparative study.
    Fagugli RM; Pasini P; Pasticci F; Ciao G; Cicconi B; Buoncristiani U
    J Nephrol; 2006; 19(1):77-83. PubMed ID: 16523430
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bioelectric impedance predicts total body water, blood pressure, and heart rate during hemodialysis in children and adolescents.
    Brooks ER; Fatallah-Shaykh SA; Langman CB; Wolf KM; Price HE
    J Ren Nutr; 2008 May; 18(3):304-11. PubMed ID: 18410888
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Comparative Study of Short-Term Blood Pressure Variability in Hemodialysis Patients with and without Intradialytic Hypertension.
    Bikos A; Angeloudi E; Memmos E; Loutradis C; Karpetas A; Ginikopoulou E; Panagoutsos S; Pasadakis P; Liakopoulos V; Papagianni A; Sarafidis P
    Am J Nephrol; 2018; 48(4):295-305. PubMed ID: 30347395
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fluid balance assessment in pediatric hemodialysis patients by using whole-body bioimpedance spectroscopy (WB-BIS).
    Khin EE; Elmaghrabi AY; Alvarado LA; Modem V; Quigley R
    Pediatr Nephrol; 2022 Oct; 37(10):2449-2456. PubMed ID: 35166921
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of sodium balance and the combination of ultrafiltration profile during sodium profiling hemodialysis on the maintenance of the quality of dialysis and sodium and fluid balances.
    Song JH; Park GH; Lee SY; Lee SW; Lee SW; Kim MJ
    J Am Soc Nephrol; 2005 Jan; 16(1):237-46. PubMed ID: 15563561
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of bioimpedance and dual-energy x-ray absorptiometry for measurement of fat mass in hemodialysis patients.
    Molfino A; Don BR; Kaysen GA
    Nephron Clin Pract; 2012; 122(3-4):127-33. PubMed ID: 23689544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.