128 related articles for article (PubMed ID: 34671536)
1. Dosimetric Benefits of Omitting Primary Tumor Beds in Postoperative Radiotherapy After Transoral Robotic Surgery Using the Auto-Planning Technique.
Cui T; Ward MC; Kittel JA; Joshi N; Koyfman SA; Xia P
Cureus; 2021 Sep; 13(9):e18065. PubMed ID: 34671536
[TBL] [Abstract][Full Text] [Related]
2. Adjuvant radiation in the TORS era: Is there a benefit to omitting the tumor bed?
Lazarev S; Todorov B; Tam J; Gupta V; Miles BA; Lee N; Bakst RL
Pract Radiat Oncol; 2017; 7(2):93-99. PubMed ID: 28274400
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric feasibility of sparing the primary site for oropharyngeal squamous cell carcinoma after transoral laser microsurgery in patients with unilateral positive neck nodes.
Fried D; Lehman-Davis M; Willson A; Kostich M; Hackman T; Lian J; Burkhardt K; Chera B
Pract Radiat Oncol; 2013; 3(4):282-6. PubMed ID: 24674399
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers.
Liu Q; Liang J; Zhou D; Krauss DJ; Chen PY; Yan D
Int J Radiat Oncol Biol Phys; 2018 Jul; 101(4):985-997. PubMed ID: 29976511
[TBL] [Abstract][Full Text] [Related]
5. [Dosimetric analysis of radiotherapy with middle shielding blocks of different widths at the lower cervical supraclavicular field for stage N2-3 nasopharyngeal carcinoma].
Li FM; Luo W; He ZC; Zhang L; Sun Y; Qin WJ; Lu LX; Han F; Liu XQ; Liu MZ
Ai Zheng; 2007 Oct; 26(10):1127-32. PubMed ID: 17927886
[TBL] [Abstract][Full Text] [Related]
6. PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization.
Liu W; Frank SJ; Li X; Li Y; Zhu RX; Mohan R
Med Phys; 2013 Feb; 40(2):021709. PubMed ID: 23387732
[TBL] [Abstract][Full Text] [Related]
7. Automatic Radiotherapy Planning for Glioblastoma Radiotherapy With Sparing of the Hippocampus and nTMS-Defined Motor Cortex.
Schuermann M; Dzierma Y; Nuesken F; Oertel J; Rübe C; Melchior P
Front Neurol; 2021; 12():787140. PubMed ID: 35095732
[TBL] [Abstract][Full Text] [Related]
8. Semiautomated head-and-neck IMRT planning using dose warping and scaling to robustly adapt plans in a knowledge database containing potentially suboptimal plans.
Schmidt M; Lo JY; Grzetic S; Lutzky C; Brizel DM; Das SK
Med Phys; 2015 Aug; 42(8):4428-34. PubMed ID: 26233173
[TBL] [Abstract][Full Text] [Related]
9. Patterns of local-regional recurrence following parotid-sparing conformal and segmental intensity-modulated radiotherapy for head and neck cancer.
Dawson LA; Anzai Y; Marsh L; Martel MK; Paulino A; Ship JA; Eisbruch A
Int J Radiat Oncol Biol Phys; 2000 Mar; 46(5):1117-26. PubMed ID: 10725621
[TBL] [Abstract][Full Text] [Related]
10. Impact of dose calculation accuracy during optimization on lung IMRT plan quality.
Li Y; Rodrigues A; Li T; Yuan L; Yin FF; Wu QJ
J Appl Clin Med Phys; 2015 Jan; 16(1):5137. PubMed ID: 25679172
[TBL] [Abstract][Full Text] [Related]
11. Initial Evaluation of a Novel Cone-Beam CT-Based Semi-Automated Online Adaptive Radiotherapy System for Head and Neck Cancer Treatment - A Timing and Automation Quality Study.
Yoon SW; Lin H; Alonso-Basanta M; Anderson N; Apinorasethkul O; Cooper K; Dong L; Kempsey B; Marcel J; Metz J; Scheuermann R; Li T
Cureus; 2020 Aug; 12(8):e9660. PubMed ID: 32923257
[TBL] [Abstract][Full Text] [Related]
12. A Dosimetric Comparison of Primary Chemoradiation Versus Postoperative Radiation for Locally Advanced Oropharyngeal Cancer.
Woo SK; Freeman C; Debenham BJ
Cureus; 2017 Nov; 9(11):e1858. PubMed ID: 29375944
[TBL] [Abstract][Full Text] [Related]
13. Magnetic resonance guided elective neck irradiation targeting individual lymph nodes: A new concept.
Reinders FCJ; Heijst TCFV; Mases J; Terhaard CHJ; Doornaert PAH; Philippens MEP; Raaijmakers CPJ
Phys Imaging Radiat Oncol; 2021 Oct; 20():76-81. PubMed ID: 35169639
[TBL] [Abstract][Full Text] [Related]
14. Knowledge-based planning using both the predicted DVH of organ-at risk and planning target volume.
Jiao SX; Wang ML; Chen LX; Liu XW
Med Eng Phys; 2022 Dec; 110():103803. PubMed ID: 35461772
[TBL] [Abstract][Full Text] [Related]
15. Evaluating the plan quality of a general head-and-neck knowledge-based planning model versus separate unilateral/bilateral models.
Luca K; Roper J; Wolf J; Kayode O; Bradley J; Stokes WA; Zhang J
Med Dosim; 2023 Spring; 48(1):44-50. PubMed ID: 36400649
[TBL] [Abstract][Full Text] [Related]
16. Volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer.
Abbas AS; Moseley D; Kassam Z; Kim SM; Cho C
J Appl Clin Med Phys; 2013 May; 14(3):4269. PubMed ID: 23652258
[TBL] [Abstract][Full Text] [Related]
17. Helical tomotherapy for the treatment of anal canal cancer: a dosimetric comparison with 3D conformal radiotherapy.
Ugurluer G; Ballerini G; Moeckli R; Matzinger O; Bourhis J; Ozsahin M
Tumori; 2015; 101(3):268-72. PubMed ID: 25908035
[TBL] [Abstract][Full Text] [Related]
18. Deep learning auto-segmentation and automated treatment planning for trismus risk reduction in head and neck cancer radiotherapy.
Thor M; Iyer A; Jiang J; Apte A; Veeraraghavan H; Allgood NB; Kouri JA; Zhou Y; LoCastro E; Elguindi S; Hong L; Hunt M; Cerviño L; Aristophanous M; Zarepisheh M; Deasy JO
Phys Imaging Radiat Oncol; 2021 Jul; 19():96-101. PubMed ID: 34746452
[TBL] [Abstract][Full Text] [Related]
19. A Model-Based Method for Assessment of Salivary Gland and Planning Target Volume Dosimetry in Volumetric-Modulated Arc Therapy Planning on Head-and-Neck Cancer.
Zhang H; Cao Y; Antone J; Riegel AC; Ghaly M; Potters L; Jamshidi A
J Med Phys; 2019; 44(3):201-206. PubMed ID: 31576068
[TBL] [Abstract][Full Text] [Related]
20. Technical Assessment of an Automated Treatment Planning on Dose Escalation of Pancreas Stereotactic Body Radiotherapy.
Wang S; Zheng D; Lin C; Lei Y; Verma V; Smith A; Ma R; Enke CA; Zhou S
Technol Cancer Res Treat; 2019 Jan; 18():1533033819851520. PubMed ID: 31195891
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]