BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 34673507)

  • 1. High Residual Gradient Following a Self-Expandable Transcatheter Aortic Valve-in-Valve Implantation - Risk Factor Analysis, Outcomes, and Survival.
    Stankowski T; Aboul-Hassan SS; Stepinski P; Gasior T; Salem M; Erkenov T; Herwig V; Harnath A; Muehle A; Sá MPBO; Fritzsche D; Perek B
    Braz J Cardiovasc Surg; 2022 Oct; 37(5):710-720. PubMed ID: 34673507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Redo procedures for degenerated stentless aortic xenografts and the role of valve-in-valve transcatheter techniques.
    Grubitzsch H; Zobel S; Christ T; Holinski S; Stangl K; Treskatsch S; Falk V; Laule M
    Eur J Cardiothorac Surg; 2017 Apr; 51(4):653-659. PubMed ID: 28062549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Severe structural deterioration of small aortic bioprostheses treated with valve-in-valve transcatheter aortic valve implantation.
    Stankowski T; Aboul-Hassan SS; Seifi-Zinab F; Herwig V; Kubikova M; Harnath A; Fritzsche D; Perek B
    J Card Surg; 2019 Jan; 34(1):7-13. PubMed ID: 30625244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Valve-in-Valve Transcatheter Aortic Valve Implantation for the Failing Surgical Perceval Bioprosthesis.
    Suleiman T; Tanseco K; Arunothayaraj S; Michail M; Cockburn J; Hadjivassilev S; Hildick-Smith D
    Cardiovasc Revasc Med; 2022 Jul; 40S():148-153. PubMed ID: 34412989
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures.
    Pibarot P; Simonato M; Barbanti M; Linke A; Kornowski R; Rudolph T; Spence M; Moat N; Aldea G; Mennuni M; Iadanza A; Amrane H; Gaia D; Kim WK; Napodano M; Baumbach H; Finkelstein A; Kobayashi J; Brecker S; Don C; Cerillo A; Unbehaun A; Attias D; Nejjari M; Jones N; Fiorina C; Tchetche D; Philippart R; Spargias K; Hernandez JM; Latib A; Dvir D
    JACC Cardiovasc Interv; 2018 Jan; 11(2):133-141. PubMed ID: 29348008
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two-year outcomes after transcatheter aortic valve-in-valve implantation in degenerated surgical valves.
    Abushouk AI; Abdelfattah O; Gad MM; Saad A; Hariri E; Isogai T; Shekhar S; Reed GW; Puri R; Yun J; Vargo PR; Weiss AJ; Burns D; Unai S; Popovic Z; Harb SC; Krishnaswamy A; Svensson LG; Johnston DR; Kapadia SR
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):860-867. PubMed ID: 36116028
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter aortic valve-in-valve implantation in failed stentless bioprostheses.
    Huczek Z; Grodecki K; Scisło P; Wilczek K; Jagielak D; Fil W; Kubler P; Olszówka P; Dąbrowski M; Frank M; Grygier M; Kidawa M; Wilimski R; Żelazowska K; Witkowski A; Kochman J; Zembala M; Opolski G; Dvir D; Wojakowski W
    J Interv Cardiol; 2018 Dec; 31(6):861-869. PubMed ID: 30009390
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Valve-in-valve implantation of a novel and small self-expandable transcatheter heart valve in degenerated small surgical bioprostheses: the Hamburg experience.
    Diemert P; Seiffert M; Frerker C; Thielsen T; Kreidel F; Bader R; Schirmer J; Conradi L; Koschyk D; Schnabel R; Reichenspurner H; Blankenberg S; Kuck KH; Treede H; Schaefer U
    Catheter Cardiovasc Interv; 2014 Sep; 84(3):486-93. PubMed ID: 24753352
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter valve-in-valve or valve-in-ring implantation with a novel balloon-expandable device in patients with bioprosthetic left side heart valves failure: 1-year follow-up from a multicenter experience.
    Moscarella E; Ielasi A; Mussayev A; Montorfano M; Mullassari A; Martin P; Testa L; Jose J; Ninios V; Toutouzas K; Giannini F; Kertesz A; Unic D; Nissen H; Ezhumalai B; Senguttuvan NB; Amat-Santos I; Seth A; Bedogni F; Tespili M
    Int J Cardiol; 2023 Apr; 376():35-45. PubMed ID: 36657566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcomes of valve-in-valve transcatheter aortic valve implantation with and without bioprosthetic valve fracture.
    Brinkmann C; Abdel-Wahab M; Bedogni F; Bhadra OD; Charbonnier G; Conradi L; Hildick-Smith D; Kargoli F; Latib A; Van Mieghem NM; Mylotte D; Landes U; Pilgrim T; Stripling J; Taramasso M; Tchétché D; Testa L; Thiele H; Webb J; Windecker S; Witt J; Wohlmuth P; Schofer J
    EuroIntervention; 2021 Nov; 17(10):848-855. PubMed ID: 34031022
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemodynamic Performances and Clinical Outcomes in Patients Undergoing Valve-in-Valve Versus Native Transcatheter Aortic Valve Implantation.
    Akodad M; Meilhac A; Lefèvre T; Cayla G; Lattuca B; Autissier C; Duflos C; Gandet T; Macia JC; Delseny D; Roubille F; Maupas E; Schmutz L; Piot C; Targosz F; Robert G; Rivalland F; Albat B; Chevalier B; Leclercq F
    Am J Cardiol; 2019 Jul; 124(1):90-97. PubMed ID: 31076081
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac conduction abnormalities in patients with degenerated bioprostheses undergoing transcatheter aortic valve-in-valve implantations and their impact on long-term outcomes.
    Stankowski T; Mangner N; Linke A; Aboul-Hassan SS; Gąsior T; Muehle A; Herwig V; Harnath A; Salem M; Szłapka M; Grimmig O; Just S; Fritzsche D; Perek B
    Int J Cardiol; 2021 May; 330():16-22. PubMed ID: 33592238
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prognostic Impact of Residual Moderate Mitral Regurgitation Following Valve-in-Valve Transcatheter Aortic Valve Implantation.
    Stankowski T; Aboul-Hassan SS; Salem M; Rochor K; Schenk S; Erkenov T; Zinab FS; Muehle A; Herwig V; Harnath A; Sá MP; Ramlawi B; Fritzsche D; Perek B
    Braz J Cardiovasc Surg; 2023 Oct; 39(1):e20230012. PubMed ID: 37889213
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Echocardiographic Versus Invasive Aortic Valve Gradients in Different Clinical Scenarios.
    Abbas AE; Khalili H; Madanat L; Elmariah S; Shannon F; Al-Azizi K; Waggoner T; Pilgrim T; Okuno T; Bavry A; Ternacle J; Christensen J; Cabau JR; Mack M; Pibarot P
    J Am Soc Echocardiogr; 2023 Dec; 36(12):1302-1314. PubMed ID: 37507058
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Chhatriwalla AK; Allen KB; Saxon JT; Cohen DJ; Aggarwal S; Hart AJ; Baron SJ; Dvir D; Borkon AM
    Circ Cardiovasc Interv; 2017 Jul; 10(7):. PubMed ID: 28698291
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
    Dvir D; Webb JG; Bleiziffer S; Pasic M; Waksman R; Kodali S; Barbanti M; Latib A; Schaefer U; Rodés-Cabau J; Treede H; Piazza N; Hildick-Smith D; Himbert D; Walther T; Hengstenberg C; Nissen H; Bekeredjian R; Presbitero P; Ferrari E; Segev A; de Weger A; Windecker S; Moat NE; Napodano M; Wilbring M; Cerillo AG; Brecker S; Tchetche D; Lefèvre T; De Marco F; Fiorina C; Petronio AS; Teles RC; Testa L; Laborde JC; Leon MB; Kornowski R;
    JAMA; 2014 Jul; 312(2):162-70. PubMed ID: 25005653
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Valve-in-valve transcatheter aortic valve implantation: the new playground for prosthesis-patient mismatch.
    Faerber G; Schleger S; Diab M; Breuer M; Figulla HR; Eichinger WB; Doenst T
    J Interv Cardiol; 2014 Jun; 27(3):287-92. PubMed ID: 24612128
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous transcatheter aortic valve implantation for degenerated surgical bioprostheses: the first case series in Asia with one-year follow-up.
    Chiam PT; Ewe SH; Soon JL; Ho KW; Sin YK; Tan SY; Lim ST; Koh TH; Chua YL
    Singapore Med J; 2016 Jul; 57(7):401-5. PubMed ID: 27193081
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Practical Approach to Transcatheter Aortic Valve Implantation and Bioprosthetic Valve Fracture in a Failed Bioprosthetic Surgical Valve.
    Vanhaverbeke M; De Backer O; Dubois C
    J Interv Cardiol; 2022; 2022():9899235. PubMed ID: 35250395
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.