BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 34676586)

  • 1. Intraoperative transit time flow measurements during off-pump coronary artery bypass surgery: The impact of coronary stenosis on competitive flow.
    Halfwerk FR; Spoor P; Mariani S; Hagmeijer R; Grandjean JG
    J Card Surg; 2022 Feb; 37(2):305-313. PubMed ID: 34676586
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood flow assessment by transit time flow measurement and its prognostic impact in coronary bypass surgery.
    Niclauss L; Masci PG; Pavon AG; Rodrigues D; Schwitter J
    J Cardiovasc Surg (Torino); 2020 Jun; 61(3):356-368. PubMed ID: 31985189
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Graft flow evaluation with intraoperative transit-time flow measurement in off-pump versus on-pump coronary artery bypass grafting.
    Leviner DB; Rosati CM; von Mücke Similon M; Amabile A; Thuijs DJFM; Di Giammarco G; Wendt D; Trachiotis GD; Kieser TM; Kappetein AP; Head SJ; Taggart DP; Puskas JD
    JTCVS Tech; 2022 Oct; 15():95-106. PubMed ID: 36276694
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transit time flow measurement predicts graft patency in off-pump coronary artery bypass grafting upon 5-year angiographic follow-up.
    Zeng C; Li X; Dai Y; Zhou Y; Li C; Liu N; Wang J
    J Cardiothorac Surg; 2021 Nov; 16(1):334. PubMed ID: 34802435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Patency rate of the internal thoracic artery to the left anterior descending artery bypass is reduced by competitive flow from the concomitant saphenous vein graft in the left coronary artery.
    Kawamura M; Nakajima H; Kobayashi J; Funatsu T; Otsuka Y; Yagihara T; Kitamura S
    Eur J Cardiothorac Surg; 2008 Oct; 34(4):833-8. PubMed ID: 18723364
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transit Time Flow Measurement in Robotic Totally Endoscopic Coronary Artery Bypass: What Do the Numbers Mean?
    Yang B; Nisivaco S; Torregrossa G; Balkhy HH
    Innovations (Phila); 2022; 17(2):136-141. PubMed ID: 35499921
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study.
    Jokinen JJ; Werkkala K; Vainikka T; Peräkylä T; Simpanen J; Ihlberg L
    Eur J Cardiothorac Surg; 2011 Jun; 39(6):918-23. PubMed ID: 21095134
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Off-pump onlay-patch grafting using the left internal mammary artery for a diffusely diseased left anterior descending artery: in-hospital and mid-term outcomes.
    Shen J; Xia L; Song K; Wang Y; Yang Y; Ding W; Ji Q; Wang C
    Coron Artery Dis; 2019 Aug; 30(5):354-359. PubMed ID: 30807293
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Role of Color Doppler Ultrasonography in the Perioperative Period of Coronary Artery Bypass Grafting: Comparison with Transit-Time Flow Measurement.
    Gao J; Zhao Z; Zhu J; Tian H; Liu Y
    Cardiology; 2021; 146(5):583-590. PubMed ID: 34192706
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Angiographic evaluation of flow distribution in sequential and composite arterial grafts for three vessel disease.
    Nakajima H; Kobayashi J; Toda K; Fujita T; Shimahara Y; Kasahara Y; Kitamura S
    Eur J Cardiothorac Surg; 2012 Apr; 41(4):763-9. PubMed ID: 22219402
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fractional flow reserve-guided coronary artery bypass grafting: can intraoperative physiologic imaging guide decision making?
    Ferguson TB; Chen C; Babb JD; Efird JT; Daggubati R; Cahill JM
    J Thorac Cardiovasc Surg; 2013 Oct; 146(4):824-835.e1. PubMed ID: 23915918
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review.
    Niclauss L
    Eur J Cardiothorac Surg; 2017 Jan; 51(1):26-33. PubMed ID: 27298393
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative Bypass Graft Flow Measurement With Transit Time Flowmetry: A Clinical Assessment.
    Amin S; Werner RS; Madsen PL; Krasopoulos G; Taggart DP
    Ann Thorac Surg; 2018 Aug; 106(2):532-538. PubMed ID: 29605596
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of the right internal mammary artery and the great saphenous vein for left anterior descending artery revascularization in patients whose left internal mammal artery cannot be used: a study based on transit-time flow measurement.
    Zhang G; Zhao Z; Chen Y; Chen S; Liu G
    J Cardiothorac Surg; 2020 Jun; 15(1):126. PubMed ID: 32503570
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio.
    Balacumaraswami L; Abu-Omar Y; Selvanayagam J; Pigott D; Taggart DP
    J Thorac Cardiovasc Surg; 2008 Mar; 135(3):533-9. PubMed ID: 18329465
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Results of the Minimally Invasive Coronary Artery Bypass Grafting Angiographic Patency Study.
    Ruel M; Shariff MA; Lapierre H; Goyal N; Dennie C; Sadel SM; Sohmer B; McGinn JT
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):203-8. PubMed ID: 24183338
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative graft verification in coronary surgery: increased diagnostic accuracy adding high-resolution epicardial ultrasonography to transit-time flow measurement.
    Di Giammarco G; Canosa C; Foschi M; Rabozzi R; Marinelli D; Masuyama S; Ibrahim BM; Ranalletta RA; Penco M; Di Mauro M
    Eur J Cardiothorac Surg; 2014 Mar; 45(3):e41-5. PubMed ID: 24335472
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Occurrence rate and fate of competitive flow of the left internal thoracic artery used in Y-composite grafts.
    Kim JS; Kang Y; Sohn SH; Hwang HY
    JTCVS Open; 2022 Sep; 11():116-126. PubMed ID: 36172425
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mid-term graft patency of right versus left internal mammary artery as arterial conduit usage for left anterior descending artery revascularisation: Insights from a single-centre study of propensity-matched data.
    Ji Q; Xia L; Shi Y; Ma R; Shen J; Lai H; Ding W; Wang C
    Int J Surg; 2017 Dec; 48():99-104. PubMed ID: 29061389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The correlation between flow pattern during cardiopulmonary bypass and patency of the coronary artery bypass grafts].
    Hagiwara H; Shirakawa M; Nakayama T; Asai T; Nakayama M; Ito T; Yano Y
    Kyobu Geka; 2005 Jul; 58(7):519-23; discussion 524-6. PubMed ID: 16004331
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.