These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 34694427)

  • 1. Endocardial left ventricular pacing.
    Elliott MK; Mehta VS; Sidhu BS; Niederer S; Rinaldi CA
    Herz; 2021 Dec; 46(6):526-532. PubMed ID: 34694427
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the wireless stimulation endocardially for CRT (WiSE-CRT) study.
    Auricchio A; Delnoy PP; Butter C; Brachmann J; Van Erven L; Spitzer S; Moccetti T; Seifert M; Markou T; Laszo K; Regoli F;
    Europace; 2014 May; 16(5):681-8. PubMed ID: 24497573
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A simultaneous X-Ray/MRI and noncontact mapping study of the acute hemodynamic effect of left ventricular endocardial and epicardial cardiac resynchronization therapy in humans.
    Ginks MR; Lambiase PD; Duckett SG; Bostock J; Chinchapatnam P; Rhode K; McPhail MJ; Simon M; Bucknall C; Carr-White G; Razavi R; Rinaldi CA
    Circ Heart Fail; 2011 Mar; 4(2):170-9. PubMed ID: 21216832
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left Ventricular Endocardial Pacing/Leadless Pacing.
    Hanley A; Heist EK
    Card Electrophysiol Clin; 2019 Mar; 11(1):155-164. PubMed ID: 30717848
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Leadless left ventricular endocardial pacing for cardiac resynchronization therapy: A systematic review and meta-analysis.
    Wijesuriya N; Elliott MK; Mehta V; Sidhu BS; Behar JM; Niederer S; Rinaldi CA
    Heart Rhythm; 2022 Jul; 19(7):1176-1183. PubMed ID: 35189383
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system.
    Sieniewicz BJ; Betts TR; James S; Turley A; Butter C; Seifert M; Boersma LVA; Riahi S; Neuzil P; Biffi M; Diemberger I; Vergara P; Arnold M; Keane DT; Defaye P; Deharo JC; Chow A; Schilling R; Behar J; Rinaldi CA
    Heart Rhythm; 2020 Aug; 17(8):1291-1297. PubMed ID: 32165181
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cardiac Resynchronization Therapy With Wireless Left Ventricular Endocardial Pacing: The SELECT-LV Study.
    Reddy VY; Miller MA; Neuzil P; Søgaard P; Butter C; Seifert M; Delnoy PP; van Erven L; Schalji M; Boersma LVA; Riahi S
    J Am Coll Cardiol; 2017 May; 69(17):2119-2129. PubMed ID: 28449772
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endocardial pacing: the wave of the future?
    Bordachar P; Ploux S; Lumens J
    Curr Cardiol Rep; 2012 Oct; 14(5):547-51. PubMed ID: 22825920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy.
    Spragg DD; Dong J; Fetics BJ; Helm R; Marine JE; Cheng A; Henrikson CA; Kass DA; Berger RD
    J Am Coll Cardiol; 2010 Aug; 56(10):774-81. PubMed ID: 20797490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endocardial left ventricular pacing improves cardiac resynchronization therapy in chronic asynchronous infarction and heart failure models.
    Strik M; Rademakers LM; van Deursen CJ; van Hunnik A; Kuiper M; Klersy C; Auricchio A; Prinzen FW
    Circ Arrhythm Electrophysiol; 2012 Feb; 5(1):191-200. PubMed ID: 22062796
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Beneficial Effect on Cardiac Resynchronization From Left Ventricular Endocardial Pacing Is Mediated by Early Access to High Conduction Velocity Tissue: Electrophysiological Simulation Study.
    Hyde ER; Behar JM; Claridge S; Jackson T; Lee AW; Remme EW; Sohal M; Plank G; Razavi R; Rinaldi CA; Niederer SA
    Circ Arrhythm Electrophysiol; 2015 Oct; 8(5):1164-72. PubMed ID: 26136400
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acute hemodynamic effect of left ventricular endocardial pacing in cardiac resynchronization therapy: assessment by pressure-volume loops.
    Padeletti L; Pieragnoli P; Ricciardi G; Perrotta L; Grifoni G; Porciani MC; Lionetti V; Valsecchi S
    Circ Arrhythm Electrophysiol; 2012 Jun; 5(3):460-7. PubMed ID: 22589286
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Endocardial left ventricular pacing across the interventricular septum for cardiac resynchronization therapy: Clinical results of a pilot study.
    Gamble JHP; Herring N; Ginks MR; Rajappan K; Bashir Y; Betts TR
    Heart Rhythm; 2018 Jul; 15(7):1017-1022. PubMed ID: 29501668
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimized Left Ventricular Endocardial Stimulation Is Superior to Optimized Epicardial Stimulation in Ischemic Patients With Poor Response to Cardiac Resynchronization Therapy: A Combined Magnetic Resonance Imaging, Electroanatomic Contact Mapping, and Hemodynamic Study to Target Endocardial Lead Placement.
    Behar JM; Jackson T; Hyde E; Claridge S; Gill J; Bostock J; Sohal M; Porter B; O'Neill M; Razavi R; Niederer S; Rinaldi CA
    JACC Clin Electrophysiol; 2016 Dec; 2(7):799-809. PubMed ID: 28066827
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Left ventricular endocardial pacing and multisite pacing to improve CRT response.
    Ploux S; Whinnett Z; Bordachar P
    J Cardiovasc Transl Res; 2012 Apr; 5(2):213-8. PubMed ID: 22234674
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement of Right Ventricular Hemodynamics with Left Ventricular Endocardial Pacing during Cardiac Resynchronization Therapy.
    Hyde ER; Behar JM; Crozier A; Claridge S; Jackson T; Sohal M; Gill JS; O'Neill MD; Razavi R; Niederer SA; Rinaldi CA
    Pacing Clin Electrophysiol; 2016 Jun; 39(6):531-41. PubMed ID: 27001004
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pacing Optimized by Left Ventricular dP/dt
    Elliott MK; Mehta VS; Rinaldi CA
    Card Electrophysiol Clin; 2022 Jun; 14(2):223-232. PubMed ID: 35715080
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Delayed trans-septal activation results in comparable hemodynamic effect of left ventricular and biventricular endocardial pacing: insights from electroanatomical mapping.
    Sohal M; Shetty A; Niederer S; Chen Z; Jackson T; Sammut E; Bostock J; Razavi R; Prinzen F; Rinaldi CA
    Circ Arrhythm Electrophysiol; 2014 Apr; 7(2):251-8. PubMed ID: 24610742
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure.
    Seifert M; Butter C
    Expert Rev Med Devices; 2016 Jun; 13(6):523-31. PubMed ID: 27157452
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Leadless left ventricular endocardial pacing for CRT upgrades in previously failed and high-risk patients in comparison with coronary sinus CRT upgrades.
    Sidhu BS; Sieniewicz B; Gould J; Elliott MK; Mehta VS; Betts TR; James S; Turley AJ; Butter C; Seifert M; Boersma LVA; Riahi S; Neuzil P; Biffi M; Diemberger I; Vergara P; Arnold M; Keane DT; Defaye P; Deharo JC; Chow A; Schilling R; Behar JM; Leclercq C; Auricchio A; Niederer SA; Rinaldi CA
    Europace; 2021 Oct; 23(10):1577-1585. PubMed ID: 34322707
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]