These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 34711186)

  • 1. Multi-infusion with integrated multiple pressure sensing allows earlier detection of line occlusions.
    Doesburg F; Oelen R; Renes MH; Lourenço PM; Touw DJ; Nijsten MW
    BMC Med Inform Decis Mak; 2021 Oct; 21(1):295. PubMed ID: 34711186
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of multiple infusion line extensions on occlusion alarm function of an infusion pump.
    Deckert D; Buerkle C; Neurauter A; Hamm P; Lindner KH; Wenzel V
    Anesth Analg; 2009 Feb; 108(2):518-20. PubMed ID: 19151281
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Syringe pumps take too long to give occlusion alarm.
    Dönmez A; Araz C; Kayhan Z
    Paediatr Anaesth; 2005 Apr; 15(4):293-6. PubMed ID: 15787919
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infusion technology: a cause for alarm.
    Hee HI; Lim SL; Tan SS
    Paediatr Anaesth; 2002 Nov; 12(9):780-5. PubMed ID: 12519137
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer.
    Park J; Jung B
    J Dent Anesth Pain Med; 2022 Apr; 22(2):129-143. PubMed ID: 35449784
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions.
    McVey E; Keith S; Herr JK; Sutter D; Pettis RJ
    J Diabetes Sci Technol; 2015 Aug; 9(6):1282-91. PubMed ID: 26319228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prolonged time to alarm in infusion devices operated at low flow rates.
    Ilan R; Fowler RA; Ferguson ND; Parshuram CS; Friedrich JO; Lapinsky SE; Biason R; Pinto R; Etchells EE
    Crit Care Med; 2008 Oct; 36(10):2763-5. PubMed ID: 18766111
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate.
    Hong KY; Lee EK; Kim Y; Choi DC; Min JJ
    J Clin Monit Comput; 2023 Oct; 37(5):1379-1386. PubMed ID: 36648629
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Pressure build-up in 2 rate-controlled syringe infusion pumps].
    Gerlif C
    Ugeskr Laeger; 1994 Apr; 156(15):2236-9. PubMed ID: 8016950
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Types and Frequency of Infusion Pump Alarms and Infusion-Interruption to Infusion-Recovery Times for Critical Short Half-Life Infusions: Retrospective Data Analysis.
    Waterson J; Bedner A
    JMIR Hum Factors; 2019 Aug; 6(3):e14123. PubMed ID: 31407667
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line.
    Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T
    Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Occlusion Detection Time in Insulin Pumps at Two Different Basal Rates.
    Freckmann G; Kamecke U; Waldenmaier D; Haug C; Ziegler R
    J Diabetes Sci Technol; 2018 May; 12(3):608-613. PubMed ID: 29284290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Arrangements of the intravenous parallel infusions with anti-reflux valves decreasing occlusion alarm delay.
    Joe HB; Moon BK; Lee YJ; Min SK
    Korean J Anesthesiol; 2014 Apr; 66(4):300-5. PubMed ID: 24851166
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of an Alarm Algorithm, With Nanotechnology Multimodal Sensor, to Predict Impending Infusion Failure and Improve Safety of Peripheral Intravenous Catheters in Neonates.
    Bosque EM
    Adv Neonatal Care; 2020 Jun; 20(3):233-243. PubMed ID: 31815770
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of central venous pressure on fluid delivery during start-up of syringe infusion pumps for microinfusion.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Oct; 33(10):837-843. PubMed ID: 37403751
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Start-up delay in syringe infusion pumps with different rates and priming techniques of intravenoust sets.
    Vieira NM; Pires MPO; Crespo GB; Nascimento LPP; Peterlini MAS; Pedreira MLG
    Rev Gaucha Enferm; 2022; 43():e20210071. PubMed ID: 35613239
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.