170 related articles for article (PubMed ID: 34711186)
1. Multi-infusion with integrated multiple pressure sensing allows earlier detection of line occlusions. Doesburg F; Oelen R; Renes MH; Lourenço PM; Touw DJ; Nijsten MW BMC Med Inform Decis Mak; 2021 Oct; 21(1):295. PubMed ID: 34711186 [TBL] [Abstract][Full Text] [Related]
2. The effects of multiple infusion line extensions on occlusion alarm function of an infusion pump. Deckert D; Buerkle C; Neurauter A; Hamm P; Lindner KH; Wenzel V Anesth Analg; 2009 Feb; 108(2):518-20. PubMed ID: 19151281 [TBL] [Abstract][Full Text] [Related]
3. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system]. Heise D; Rathgeber J; Kettler D Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448 [TBL] [Abstract][Full Text] [Related]
4. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ]. Schulz G; Fischer J; Neff T; Bänziger O; Weiss M Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074 [TBL] [Abstract][Full Text] [Related]
5. Syringe pumps take too long to give occlusion alarm. Dönmez A; Araz C; Kayhan Z Paediatr Anaesth; 2005 Apr; 15(4):293-6. PubMed ID: 15787919 [TBL] [Abstract][Full Text] [Related]
6. Infusion technology: a cause for alarm. Hee HI; Lim SL; Tan SS Paediatr Anaesth; 2002 Nov; 12(9):780-5. PubMed ID: 12519137 [TBL] [Abstract][Full Text] [Related]
8. Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer. Park J; Jung B J Dent Anesth Pain Med; 2022 Apr; 22(2):129-143. PubMed ID: 35449784 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions. McVey E; Keith S; Herr JK; Sutter D; Pettis RJ J Diabetes Sci Technol; 2015 Aug; 9(6):1282-91. PubMed ID: 26319228 [TBL] [Abstract][Full Text] [Related]
10. Prolonged time to alarm in infusion devices operated at low flow rates. Ilan R; Fowler RA; Ferguson ND; Parshuram CS; Friedrich JO; Lapinsky SE; Biason R; Pinto R; Etchells EE Crit Care Med; 2008 Oct; 36(10):2763-5. PubMed ID: 18766111 [TBL] [Abstract][Full Text] [Related]
11. Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate. Hong KY; Lee EK; Kim Y; Choi DC; Min JJ J Clin Monit Comput; 2023 Oct; 37(5):1379-1386. PubMed ID: 36648629 [TBL] [Abstract][Full Text] [Related]
13. Types and Frequency of Infusion Pump Alarms and Infusion-Interruption to Infusion-Recovery Times for Critical Short Half-Life Infusions: Retrospective Data Analysis. Waterson J; Bedner A JMIR Hum Factors; 2019 Aug; 6(3):e14123. PubMed ID: 31407667 [TBL] [Abstract][Full Text] [Related]
14. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line. Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409 [TBL] [Abstract][Full Text] [Related]
15. Occlusion Detection Time in Insulin Pumps at Two Different Basal Rates. Freckmann G; Kamecke U; Waldenmaier D; Haug C; Ziegler R J Diabetes Sci Technol; 2018 May; 12(3):608-613. PubMed ID: 29284290 [TBL] [Abstract][Full Text] [Related]
16. Arrangements of the intravenous parallel infusions with anti-reflux valves decreasing occlusion alarm delay. Joe HB; Moon BK; Lee YJ; Min SK Korean J Anesthesiol; 2014 Apr; 66(4):300-5. PubMed ID: 24851166 [TBL] [Abstract][Full Text] [Related]
17. Development of an Alarm Algorithm, With Nanotechnology Multimodal Sensor, to Predict Impending Infusion Failure and Improve Safety of Peripheral Intravenous Catheters in Neonates. Bosque EM Adv Neonatal Care; 2020 Jun; 20(3):233-243. PubMed ID: 31815770 [TBL] [Abstract][Full Text] [Related]
18. Effect of central venous pressure on fluid delivery during start-up of syringe infusion pumps for microinfusion. Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M Paediatr Anaesth; 2023 Oct; 33(10):837-843. PubMed ID: 37403751 [TBL] [Abstract][Full Text] [Related]
19. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting. Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721 [TBL] [Abstract][Full Text] [Related]
20. Start-up delay in syringe infusion pumps with different rates and priming techniques of intravenoust sets. Vieira NM; Pires MPO; Crespo GB; Nascimento LPP; Peterlini MAS; Pedreira MLG Rev Gaucha Enferm; 2022; 43():e20210071. PubMed ID: 35613239 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]