427 related articles for article (PubMed ID: 34715586)
1. Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1.
Zamzami MA; Rabbani G; Ahmad A; Basalah AA; Al-Sabban WH; Nate Ahn S; Choudhry H
Bioelectrochemistry; 2022 Feb; 143():107982. PubMed ID: 34715586
[TBL] [Abstract][Full Text] [Related]
2. Rapid Detection of SARS-CoV-2 Antigens Using High-Purity Semiconducting Single-Walled Carbon Nanotube-Based Field-Effect Transistors.
Shao W; Shurin MR; Wheeler SE; He X; Star A
ACS Appl Mater Interfaces; 2021 Mar; 13(8):10321-10327. PubMed ID: 33596036
[TBL] [Abstract][Full Text] [Related]
3. Electrochemical biosensing platform based on hydrogen bonding for detection of the SARS-CoV-2 spike antibody.
Liv L; Yener M; Çoban G; Can ŞA
Anal Bioanal Chem; 2022 Jan; 414(3):1313-1322. PubMed ID: 34741650
[TBL] [Abstract][Full Text] [Related]
4. A triple-aptamer tetrahedral DNA nanostructures based carbon-nanotube-array transistor biosensor for rapid virus detection.
Ma S; Ren Q; Jiang L; Liu Z; Zhu Y; Zhu J; Zhang Y; Zhang M
Talanta; 2024 Jan; 266(Pt 1):124973. PubMed ID: 37506519
[TBL] [Abstract][Full Text] [Related]
5. Voltammetric-based immunosensor for the detection of SARS-CoV-2 nucleocapsid antigen.
Eissa S; Alhadrami HA; Al-Mozaini M; Hassan AM; Zourob M
Mikrochim Acta; 2021 May; 188(6):199. PubMed ID: 34041585
[TBL] [Abstract][Full Text] [Related]
6. Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor.
Mojsoska B; Larsen S; Olsen DA; Madsen JS; Brandslund I; Alatraktchi FA
Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33429915
[TBL] [Abstract][Full Text] [Related]
7. Graphene-Based Field-Effect Transistor for Ultrasensitive Immunosensing of SARS-CoV-2 Spike S1 Antigen.
Shahdeo D; Chauhan N; Majumdar A; Ghosh A; Gandhi S
ACS Appl Bio Mater; 2022 Jul; 5(7):3563-3572. PubMed ID: 35775242
[TBL] [Abstract][Full Text] [Related]
8. Label-free detection of SARS-CoV-2 Spike S1 antigen triggered by electroactive gold nanoparticles on antibody coated fluorine-doped tin oxide (FTO) electrode.
Roberts A; Mahari S; Shahdeo D; Gandhi S
Anal Chim Acta; 2021 Dec; 1188():339207. PubMed ID: 34794571
[TBL] [Abstract][Full Text] [Related]
9. Ultrasensitive Detection of COVID-19 Causative Virus (SARS-CoV-2) Spike Protein Using Laser Induced Graphene Field-Effect Transistor.
Cui TR; Qiao YC; Gao JW; Wang CH; Zhang Y; Han L; Yang Y; Ren TL
Molecules; 2021 Nov; 26(22):. PubMed ID: 34834039
[TBL] [Abstract][Full Text] [Related]
10. Amplification-Free Detection of SARS-CoV-2 Down to Single Virus Level by Portable Carbon Nanotube Biosensors.
Liang Y; Xiao M; Xie J; Li J; Zhang Y; Liu H; Zhang Y; He J; Zhang G; Wei N; Peng LM; Ke Y; Zhang ZY
Small; 2023 Aug; 19(34):e2208198. PubMed ID: 37046180
[TBL] [Abstract][Full Text] [Related]
11. Paper-based electrochemical biosensor for diagnosing COVID-19: Detection of SARS-CoV-2 antibodies and antigen.
Yakoh A; Pimpitak U; Rengpipat S; Hirankarn N; Chailapakul O; Chaiyo S
Biosens Bioelectron; 2021 Mar; 176():112912. PubMed ID: 33358057
[TBL] [Abstract][Full Text] [Related]
12. A portable transistor immunosensor for fast identification of porcine epidemic diarrhea virus.
Hu X; Zhang M; Liu Y; Li YT; Li W; Li T; Li J; Xiao X; He Q; Zhang ZY; Zhang GJ
J Nanobiotechnology; 2024 May; 22(1):239. PubMed ID: 38735951
[TBL] [Abstract][Full Text] [Related]
13. Rapid SARS-CoV-2 Spike Protein Detection by Carbon Nanotube-Based Near-Infrared Nanosensors.
Pinals RL; Ledesma F; Yang D; Navarro N; Jeong S; Pak JE; Kuo L; Chuang YC; Cheng YW; Sun HY; Landry MP
Nano Lett; 2021 Mar; 21(5):2272-2280. PubMed ID: 33635655
[TBL] [Abstract][Full Text] [Related]
14. Development of a Portable, Ultra-Rapid and Ultra-Sensitive Cell-Based Biosensor for the Direct Detection of the SARS-CoV-2 S1 Spike Protein Antigen.
Mavrikou S; Moschopoulou G; Tsekouras V; Kintzios S
Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32486477
[TBL] [Abstract][Full Text] [Related]
15. Clinical Application of the Novel Cell-Based Biosensor for the Ultra-Rapid Detection of the SARS-CoV-2 S1 Spike Protein Antigen: A Practical Approach.
Mavrikou S; Tsekouras V; Hatziagapiou K; Paradeisi F; Bakakos P; Michos A; Koutsoukou A; Konstantellou E; Lambrou GI; Koniari E; Tatsi EB; Papaparaskevas J; Iliopoulos D; Chrousos GP; Kintzios S
Biosensors (Basel); 2021 Jul; 11(7):. PubMed ID: 34356695
[TBL] [Abstract][Full Text] [Related]
16. Ultrasensitive and Simultaneous Detection of Two Specific SARS-CoV-2 Antigens in Human Specimens Using Direct/Enrichment Dual-Mode Fluorescence Lateral Flow Immunoassay.
Wang C; Cheng X; Liu L; Zhang X; Yang X; Zheng S; Rong Z; Wang S
ACS Appl Mater Interfaces; 2021 Sep; 13(34):40342-40353. PubMed ID: 34412466
[TBL] [Abstract][Full Text] [Related]
17. Highly sensitive, scalable, and rapid SARS-CoV-2 biosensor based on In
Chen M; Cui D; Zhao Z; Kang D; Li Z; Albawardi S; Alsageer S; Alamri F; Alhazmi A; Amer MR; Zhou C
Nano Res; 2022; 15(6):5510-5516. PubMed ID: 35371413
[TBL] [Abstract][Full Text] [Related]
18. Functionalized TiO
Vadlamani BS; Uppal T; Verma SC; Misra M
Sensors (Basel); 2020 Oct; 20(20):. PubMed ID: 33080785
[TBL] [Abstract][Full Text] [Related]
19. Electrochemical immunosensor with Cu
Rahmati Z; Roushani M; Hosseini H; Choobin H
Mikrochim Acta; 2021 Mar; 188(3):105. PubMed ID: 33651173
[TBL] [Abstract][Full Text] [Related]
20. Selective and electronic detection of COVID-19 (Coronavirus) using carbon nanotube field effect transistor-based biosensor: A proof-of-concept study.
Thanihaichelvan M; Surendran SN; Kumanan T; Sutharsini U; Ravirajan P; Valluvan R; Tharsika T
Mater Today Proc; 2022; 49():2546-2549. PubMed ID: 33996512
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]