These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 34717440)

  • 1. Study of the characteristics of combined insulation in compact pulse transformers.
    Xiong C; Chen R; Geng J; Cheng X; Yang J; Dai Q
    Rev Sci Instrum; 2021 Oct; 92(10):104712. PubMed ID: 34717440
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental dataset on the tensile and compressive mechanical properties of plain Kraft and crepe papers used as insulation in power transformers after ageing in mineral oil.
    Oria C; Carrascal I; Ferreño D; Fernández I; Ortiz A
    Data Brief; 2021 Jun; 36():107031. PubMed ID: 33997193
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accurate Assessment of Moisture Content and Degree of Polymerization in Power Transformers via Dielectric Response Sensing.
    Kunakorn A; Pramualsingha S; Yutthagowith P; Nimsanong P; Kittiratsatcha S
    Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dielectric Strength of Nanofluid-Impregnated Transformer Solid Insulation.
    Pérez-Rosa D; Montero A; García B; Burgos JC
    Nanomaterials (Basel); 2022 Nov; 12(23):. PubMed ID: 36500752
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative Study on the Thermal-Aging Characteristics of Cellulose Insulation Polymer Immersed in New Three-Element Mixed Oil and Mineral Oil.
    Feng D; Hao J; Liao R; Chen X; Cheng L; Liu M
    Polymers (Basel); 2019 Aug; 11(8):. PubMed ID: 31382382
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On-load measurement method for the reliability of distribution transformers.
    Adesina LM; Abdulkareem A; Ogunbiyi O; Ibrahim O
    MethodsX; 2020; 7():101089. PubMed ID: 33134095
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Note: A high-energy-density Tesla-type pulse generator with novel insulating oil.
    Liu S; Su J; Fan X
    Rev Sci Instrum; 2017 Sep; 88(9):096101. PubMed ID: 28964179
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A compact repetitive high energy-density accelerator HEART-20 based on propylene carbonate pulse forming line.
    Zhang Z; Liu S; Yang H; Li D; Fan Y; Zhang J
    Rev Sci Instrum; 2022 Oct; 93(10):104703. PubMed ID: 36319348
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aging Characteristics of Transformer Oil-Impregnated Insulation Paper Based on Trap Parameters.
    Wei Y; Han W; Li G; Liang X; Gu Z; Hu K
    Polymers (Basel); 2021 Apr; 13(9):. PubMed ID: 33921999
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a moisture-in-solid-insulation sensor for power transformers.
    García B; García D; Robles G
    Sensors (Basel); 2015 Feb; 15(2):3610-24. PubMed ID: 25658393
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Moisture Prediction of Transformer Oil-Immersed Polymer Insulation by Applying a Support Vector Machine Combined with a Genetic Algorithm.
    Zhang Y; Li J; Fan X; Liu J; Zhang H
    Polymers (Basel); 2020 Jul; 12(7):. PubMed ID: 32708631
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A combined compensation method for the output voltage of an insulated core transformer power supply.
    Yang L; Yang J; Liu KF; Qin B; Chen DZ
    Rev Sci Instrum; 2014 Jun; 85(6):063302. PubMed ID: 24985809
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics of 3D Printed Biopolymers for Applications in High-Voltage Electrical Insulation.
    Sekula R; Immonen K; Metsä-Kortelainen S; Kuniewski M; Zydroń P; Kalpio T
    Polymers (Basel); 2023 May; 15(11):. PubMed ID: 37299319
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A compact high-voltage pulse generator based on pulse transformer with closed magnetic core.
    Zhang Y; Liu J; Cheng X; Bai G; Zhang H; Feng J; Liang B
    Rev Sci Instrum; 2010 Mar; 81(3):033302. PubMed ID: 20370165
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Comparative Analysis Applied to the Partial Discharges Identification in Dry-Type Transformers by Hall and Acoustic Emission Sensors.
    de Castro BA; Dos Santos VV; Lucas GB; Ardila-Rey JA; Riehl RR; Andreoli AL
    Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35270863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of ultrasonic treatment process on pour point of vegetable oils based liquid insulation.
    Moosasait B; Maria Siluvairaj WI
    Ultrason Sonochem; 2021 Mar; 71():105380. PubMed ID: 33161317
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Power density of piezoelectric transformers improved using a contact heat transfer structure.
    Shao WW; Chen LJ; Pan CL; Liu YB; Feng ZH
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jan; 59(1):73-81. PubMed ID: 22293737
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation on a fast rise time high voltage pulse transformer.
    Li S; Gao J; Shi C; Liu X; Yang H
    Rev Sci Instrum; 2019 Dec; 90(12):124704. PubMed ID: 31893841
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Towards Online Ageing Detection in Transformer Oil: A Review.
    Elele U; Nekahi A; Arshad A; Fofana I
    Sensors (Basel); 2022 Oct; 22(20):. PubMed ID: 36298273
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.
    Castro B; Clerice G; Ramos C; Andreoli A; Baptista F; Campos F; Ulson J
    Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27517931
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.