BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 34737954)

  • 1. Knowledge-Based Planning for Robustly Optimized Intensity-Modulated Proton Therapy of Head and Neck Cancer Patients.
    Xu Y; Cyriac J; De Ornelas M; Bossart E; Padgett K; Butkus M; Diwanji T; Samuels S; Samuels MA; Dogan N
    Front Oncol; 2021; 11():737901. PubMed ID: 34737954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small-spot intensity-modulated proton versus volumetric-modulated arc therapies.
    Liu C; Bhangoo RS; Sio TT; Yu NY; Shan J; Chiang JS; Ding JX; Rule WG; Korte S; Lara P; Ding X; Bues M; Hu Y; DeWees T; Ashman JB; Liu W
    J Appl Clin Med Phys; 2019 Jul; 20(7):15-27. PubMed ID: 31112371
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Small-spot intensity-modulated proton therapy and volumetric-modulated arc therapies for patients with locally advanced non-small-cell lung cancer: A dosimetric comparative study.
    Liu C; Sio TT; Deng W; Shan J; Daniels TB; Rule WG; Lara PR; Korte SM; Shen J; Ding X; Schild SE; Bues M; Liu W
    J Appl Clin Med Phys; 2018 Nov; 19(6):140-148. PubMed ID: 30328674
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical Note: Treatment planning system (TPS) approximations matter - comparing intensity-modulated proton therapy (IMPT) plan quality and robustness between a commercial and an in-house developed TPS for nonsmall cell lung cancer (NSCLC).
    Liu C; Yu NY; Shan J; Bhangoo RS; Daniels TB; Chiang JS; Ding X; Lara P; Patrick CL; Archuleta JP; DeWees T; Hu Y; Schild SE; Bues M; Sio TT; Liu W
    Med Phys; 2019 Nov; 46(11):4755-4762. PubMed ID: 31498885
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric comparison of intensity modulated radiotherapy and intensity modulated proton therapy in the treatment of recurrent nasopharyngeal carcinoma.
    Hung HM; Chan OCM; Mak CH; Hung WM; Ng WT; Lee MCH
    Med Dosim; 2022 Spring; 47(1):14-19. PubMed ID: 34470708
    [TBL] [Abstract][Full Text] [Related]  

  • 6. PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization.
    Liu W; Frank SJ; Li X; Li Y; Zhu RX; Mohan R
    Med Phys; 2013 Feb; 40(2):021709. PubMed ID: 23387732
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp.
    Mizuno T; Tomita N; Takaoka T; Tomida M; Fukuma H; Tsuchiya T; Shibamoto Y
    Technol Cancer Res Treat; 2021; 20():1533033820985866. PubMed ID: 33517860
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of Knowledge-Based Planning for Prostate Intensity Modulated Proton Therapy.
    Xu Y; Brovold N; Cyriac J; Bossart E; Padgett K; Butkus M; Diwanj T; King A; Dal Pra A; Abramowitz M; Pollack A; Dogan N
    Int J Part Ther; 2021; 8(2):62-72. PubMed ID: 34722812
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Training and validation of a knowledge-based dose-volume histogram predictive model in the optimisation of intensity-modulated proton and volumetric modulated arc photon plans for pleural mesothelioma patients.
    Franceschini D; Cozzi L; Fogliata A; Marini B; Di Cristina L; Dominici L; Spoto R; Franzese C; Navarria P; Comito T; Reggiori G; Tomatis S; Scorsetti M
    Radiat Oncol; 2022 Aug; 17(1):150. PubMed ID: 36028862
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases.
    Tran A; Zhang J; Woods K; Yu V; Nguyen D; Gustafson G; Rosen L; Sheng K
    Radiat Oncol; 2017 Jan; 12(1):10. PubMed ID: 28077128
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cone beam CT-based adaptive intensity modulated proton therapy assessment using automated planning for head-and-neck cancer.
    Xu Y; Jin W; Butkus M; De Ornelas M; Cyriac J; Studenski MT; Padgett K; Simpson G; Samuels S; Samuels M; Dogan N
    Radiat Oncol; 2024 Jan; 19(1):13. PubMed ID: 38263237
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigating the utilization of beam-specific apertures for the intensity-modulated proton therapy (IMPT) head and neck cancer plans.
    Rana S; Storey M; Manthala Padannayil N; Shamurailatpam DS; Bennouna J; George J; Chang J
    Med Dosim; 2021 Summer; 46(2):e7-e11. PubMed ID: 33246881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetric evaluation of photons versus protons in postmastectomy planning for ultrahypofractionated breast radiotherapy.
    Oonsiri P; Nantavithya C; Lertbutsayanukul C; Sarsitthithum T; Vimolnoch M; Tawonwong T; Saksornchai K
    Radiat Oncol; 2022 Jan; 17(1):20. PubMed ID: 35093111
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intensity Modulated Proton Therapy Better Spares Non-Adjacent Organs and Reduces the Risk of Secondary Malignant Neoplasms in the Treatment of Sinonasal Cancers.
    Lewis L; Kreinbrink P; Richardson M; Westerfield M; Doberstein M; Zhang Y; Redmond K; Takiar V
    Med Dosim; 2022 Summer; 47(2):117-122. PubMed ID: 34952761
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Role of Plan Robustness Evaluation in Comparing Protons and Photons Plans - An Application on IMPT and IMRT Plans in Skull Base Chordomas.
    Noufal MP; Widesott L; Sharma SD; Righetto R; Cianchetti M; Schwarz M
    J Med Phys; 2020; 45(4):206-214. PubMed ID: 33953495
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating the plan quality of a general head-and-neck knowledge-based planning model versus separate unilateral/bilateral models.
    Luca K; Roper J; Wolf J; Kayode O; Bradley J; Stokes WA; Zhang J
    Med Dosim; 2023 Spring; 48(1):44-50. PubMed ID: 36400649
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A New Proton Therapy Solution Provides Superior Cardiac Sparing Compared With Photon Therapy in Whole Lung Irradiation for Pediatric Tumor Patients.
    Sha X; Duan J; Lin X; Zhu J; Zhang R; Sun T; Wang H; Meng X; Yin Y
    Front Oncol; 2020; 10():611514. PubMed ID: 33604292
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Advancing knowledge-based intensity modulated proton planning for adaptive treatment of high-risk prostate cancer.
    Johnson CL; Hasan S; Huang S; Lin H; Gorovets D; Shim A; Apgar T; Yu F; Tsai P
    Med Dosim; 2024 Spring; 49(1):19-24. PubMed ID: 37914563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PTV-based VMAT vs. robust IMPT for head-and-neck cancer: A probabilistic uncertainty analysis of clinical plan evaluation with the Dutch model-based selection.
    Rojo-Santiago J; Korevaar E; Perkó Z; Both S; Habraken SJM; Hoogeman MS
    Radiother Oncol; 2023 Sep; 186():109729. PubMed ID: 37301261
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intensity-modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non-small cell lung cancer.
    Shan J; Yang Y; Schild SE; Daniels TB; Wong WW; Fatyga M; Bues M; Sio TT; Liu W
    Med Phys; 2020 Nov; 47(11):5428-5440. PubMed ID: 32964474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.