BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 34741904)

  • 1. An in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia.
    Qian S; Connolly A; Mendonca-Costa C; Campos F; Williams SE; Whitaker J; Rinaldi CA; Bishop MJ
    Comput Biol Med; 2021 Dec; 139():104987. PubMed ID: 34741904
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails.
    Janardhan AH; Li W; Fedorov VV; Yeung M; Wallendorf MJ; Schuessler RB; Efimov IR
    J Am Coll Cardiol; 2012 Dec; 60(23):2393-8. PubMed ID: 23141483
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts.
    Qian S; Connolly A; Mendonca-Costa C; Campos F; Rodero C; Whitaker J; Rinaldi CA; Bishop MJ
    Europace; 2023 Feb; 25(2):716-725. PubMed ID: 36197749
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Progressive implantable cardioverter-defibrillator therapies for ventricular tachycardia: The efficacy and safety of multiple bursts, ramps, and low-energy shocks.
    Strik M; Ramirez FD; Welte N; Bonnin T; Abu-Alrub S; Eschalier R; Haïssaguerre M; Ritter P; Ploux S; Bordachar P
    Heart Rhythm; 2020 Dec; 17(12):2072-2077. PubMed ID: 32739474
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of a programming algorithm for the third tachycardia zone in a fourth-generation implantable cardioverter-defibrillator.
    Neglia JJ; Krol RB; Giorgberidze I; Mathew P; Lewis C; Munsif AN; Saksena S
    J Interv Card Electrophysiol; 1997 Feb; 1(1):49-56. PubMed ID: 9869951
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.
    Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ
    Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcomes of defibrillator therapy in catecholaminergic polymorphic ventricular tachycardia.
    Roses-Noguer F; Jarman JW; Clague JR; Till J
    Heart Rhythm; 2014 Jan; 11(1):58-66. PubMed ID: 24120999
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experience with a third-generation implantable cardioverter-defibrillator.
    Saksena S; Mehta D; Krol RB; Tullo NG; Saxena A; Kaushik R; Neglia J
    Am J Cardiol; 1991 Jun; 67(16):1375-84. PubMed ID: 2042568
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of elevated heart rate preceding the onset of ventricular tachycardia on antitachycardia pacing effectiveness in patients with implantable cardioverter defibrillators.
    Kouakam C; Lauwerier B; Klug D; Jarwe M; Marquié C; Lacroix D; Kacet S
    Am J Cardiol; 2003 Jul; 92(1):26-32. PubMed ID: 12842240
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conceptual Intra-Cardiac Electrode Configurations That Facilitate Directional Cardiac Stimulation for Optimal Electrotherapy.
    Connolly A; Williams S; Rhode K; Rinaldi CA; Bishop MJ
    IEEE Trans Biomed Eng; 2019 May; 66(5):1259-1268. PubMed ID: 31021745
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results.
    Wathen MS; DeGroot PJ; Sweeney MO; Stark AJ; Otterness MF; Adkisson WO; Canby RC; Khalighi K; Machado C; Rubenstein DS; Volosin KJ;
    Circulation; 2004 Oct; 110(17):2591-6. PubMed ID: 15492306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Timing of defibrillation shocks for resuscitation of rapid ventricular tachycardia: does it make a difference?
    Turner I; Turner S; Grace AA
    Resuscitation; 2009 Feb; 80(2):183-8. PubMed ID: 19091453
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of anti-tachycardia pacing for terminating fast ventricular tachycardia in Japanese implantable cardioverter defibrillator patients. Primary results of the SATISFACTION study.
    Watanabe T; Inoue K; Kashiwase K; Mine T; Hirooka K; Shutta R; Okuyama Y; Mizuno H; Shimoshige S; Takenaka S; Sumiyoshi T; Yambe Y; Shirota K; Nitta J; Ito M; Keida T; Nanto S
    Circ J; 2014; 78(11):2643-50. PubMed ID: 25262963
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Etiology and Programming Effects on Shock Efficacy in ICD Recipients.
    Bertomeu-González V; Moreno-Arribas J; Castillo-Castillo J; Martínez-Ferrer J; Viñolas X; Rodríguez A; Díaz-Infante E; Fernández-Lozano I; Alzueta J; Fontenla A
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):73-80. PubMed ID: 26450114
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Antitachycardia pacing for very fast ventricular tachycardia and low-energy shock for ventricular arrhythmias in patients with implantable defibrillators.
    Sivagangabalan G; Chik W; Zaman S; Stafford W; Hayes J; Denman R; Young G; Sanders P; Kovoor P
    Am J Cardiol; 2013 Oct; 112(8):1153-7. PubMed ID: 23891430
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Shock Reduction With Multiple Bursts of Antitachycardia Pacing Therapies to Treat Fast Ventricular Tachyarrhythmias in Patients With Implantable Cardioverter Defibrillators: A Multicenter Study.
    Anguera I; Dallaglio P; Martínez-Ferrer J; Rodríguez A; Alzueta J; Pérez-Villacastín J; Porres JM; Viñolas X; Fontenla A; Fernández-Lozano I; García-Alberola A; Sabaté X
    J Cardiovasc Electrophysiol; 2015 Jul; 26(7):774-82. PubMed ID: 25916814
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implantable cardioverter defibrillator shock reduction using new antitachycardia pacing therapies.
    Wathen M
    Am Heart J; 2007 Apr; 153(4 Suppl):44-52. PubMed ID: 17394902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Shock-induced, but not terminated ventricular tachycardia in a patient with implantable defibrillator].
    Kühlkamp V; Dörnberger V; Mermi J; Mewis C; Seipel L
    Z Kardiol; 1996 May; 85(5):306-11. PubMed ID: 8711942
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endocardial pacing, cardioversion and defibrillation using a braided endocardial lead system.
    Saksena S; Luceri R; Krol RB; Brownstein S; Burkhardt E; Accorti P; Brewer G; Scott S; Callaghan F; Livingston A
    Am J Cardiol; 1993 Apr; 71(10):834-41. PubMed ID: 8456763
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Antitachycardia pacing and low-energy cardioversion for ventricular tachycardia termination: a clinical perspective.
    Estes NA; Haugh CJ; Wang PJ; Manolis AS
    Am Heart J; 1994 Apr; 127(4 Pt 2):1038-46. PubMed ID: 8160578
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.