These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 34744319)

  • 21. Skeletal muscle and glioma oxygenation by carbogen inhalation in rats: a longitudinal study by EPR oximetry using single-probe implantable oxygen sensors.
    Hou H; Khan N; Lariviere J; Hodge S; Chen EY; Jarvis LA; Eastman A; Williams BB; Kuppusamy P; Swartz HM
    Adv Exp Med Biol; 2014; 812():97-103. PubMed ID: 24729220
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An implantable Teflon chip holding lithium naphthalocyanine microcrystals for secure, safe, and repeated measurements of pO2 in tissues.
    Pandian RP; Meenakshisundaram G; Bratasz A; Eteshola E; Lee SC; Kuppusamy P
    Biomed Microdevices; 2010 Jun; 12(3):381-7. PubMed ID: 20058084
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Retrievable micro-inserts containing oxygen sensors for monitoring tissue oxygenation using EPR oximetry.
    Dinguizli M; Beghein N; Gallez B
    Physiol Meas; 2008 Nov; 29(11):1247-54. PubMed ID: 18843166
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Nanofiber-based paramagnetic probes for rapid, real-time biomedical oximetry.
    Bhallamudi VP; Xue R; Purser CM; Presley KF; Banasavadi-Siddegowda YK; Hwang J; Kaur B; Hammel PC; Poirier MG; Lannutti JJ; Pandian RP
    Biomed Microdevices; 2016 Apr; 18(2):38. PubMed ID: 27106026
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization of a clinically used charcoal suspension for in vivo EPR oximetry.
    Desmet CM; Tran LBA; Danhier P; Gallez B
    MAGMA; 2019 Apr; 32(2):205-212. PubMed ID: 30209636
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Injectable LiNc-BuO loaded microspheres as in vivo EPR oxygen sensors after co-implantation with tumor cells.
    Frank J; Gündel D; Drescher S; Thews O; Mäder K
    Free Radic Biol Med; 2015 Dec; 89():741-9. PubMed ID: 26459034
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Deep-tissue oxygen monitoring in the brain of rabbits for stroke research.
    Khan N; Hou H; Eskey CJ; Moodie K; Gohain S; Du G; Hodge S; Culp WC; Kuppusamy P; Swartz HM
    Stroke; 2015 Mar; 46(3):e62-6. PubMed ID: 25613304
    [No Abstract]   [Full Text] [Related]  

  • 28. Estimation of pO
    Demidenko E; Kmiec MM; Kuppusamy P
    J Magn Reson; 2021 Jul; 328():106992. PubMed ID: 33965648
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Measurement of pO
    Hou H; Khan N; Kuppusamy P
    Adv Exp Med Biol; 2017; 977():313-318. PubMed ID: 28685460
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electron paramagnetic resonance assessment of brain tissue oxygen tension in anesthetized rats.
    Hou H; Grinberg OY; Taie S; Leichtweis S; Miyake M; Grinberg S; Xie H; Csete M; Swartz HM
    Anesth Analg; 2003 May; 96(5):1467-1472. PubMed ID: 12707151
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Increased oxygenation of intracranial tumors by efaproxyn (efaproxiral), an allosteric hemoglobin modifier: In vivo EPR oximetry study.
    Hou H; Khan N; O'Hara JA; Grinberg OY; Dunn JF; Abajian MA; Wilmot CM; Demidenko E; Lu S; Steffen RP; Swartz HM
    Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1503-9. PubMed ID: 15817356
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The measurement of oxygen in vivo using EPR techniques.
    Swartz HM; Clarkson RB
    Phys Med Biol; 1998 Jul; 43(7):1957-75. PubMed ID: 9703059
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measuring Flap Oxygen Using Electron Paramagnetic Resonance Oximetry.
    Polacco MA; Hou H; Kuppusamy P; Chen EY
    Laryngoscope; 2019 Dec; 129(12):E415-E419. PubMed ID: 31034638
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo electron paramagnetic resonance oximetry with particulate materials.
    Dunn JF; Swartz HM
    Methods; 2003 Jun; 30(2):159-66. PubMed ID: 12725782
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vivo multisite oximetry using EPR-NMR coimaging.
    Ahmad R; Caia G; Potter LC; Petryakov S; Kuppusamy P; Zweier JL
    J Magn Reson; 2010 Nov; 207(1):69-77. PubMed ID: 20850361
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effects of anesthesia on cerebral tissue oxygen tension: use of EPR oximetry to make repeated measurements.
    Swartz HM; Taie S; Miyake M; Grinberg OY; Hou H; el-Kadi H; Dunn JF
    Adv Exp Med Biol; 2003; 530():569-75. PubMed ID: 14562753
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Carbon blacks as EPR sensors for localized measurements of tissue oxygenation.
    Lan M; Beghein N; Charlier N; Gallez B
    Magn Reson Med; 2004 Jun; 51(6):1272-8. PubMed ID: 15170849
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry.
    Gallez B; Jordan BF; Baudelet C
    Magn Reson Med; 1999 Jul; 42(1):193-6. PubMed ID: 10398966
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development and evaluation of biocompatible inks for the local measurement of oxygen using in vivo EPR.
    Charlier N; Beghein N; Gallez B
    NMR Biomed; 2004 Aug; 17(5):303-10. PubMed ID: 15366029
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of lithium naphthalocyanine (LiNc) microcrystals for biological EPR oximetry.
    Pandian RP; Chacko SM; Kuppusamy ML; Rivera BK; Kuppusamy P
    Adv Exp Med Biol; 2011; 701():29-36. PubMed ID: 21445766
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.