These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 3475269)

  • 21. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.
    Itagaki T; Bennett DJ; Chenelle CT; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):10-21. PubMed ID: 27879380
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
    El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
    Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury.
    Custer JW; Watson CM; Dwyer J; Kaczka DW; Simon BA; Easley RB
    Pediatr Crit Care Med; 2011 Nov; 12(6):e357-61. PubMed ID: 21317679
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
    Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
    Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow LC; Vanderhal A; Raber J; Sola A
    Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Volume not guaranteed: closed endotracheal suction compromises ventilation in volume-targeted mode.
    Kiraly NJ; Tingay DG; Mills JF; Dargaville PA; Copnell B
    Neonatology; 2011; 99(1):78-82. PubMed ID: 20733330
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode].
    Imanaka H; Takeuchi M; Tachibana K; Takauchi Y; Inamori N; Nishimura M
    Masui; 2005 Mar; 54(3):254-9. PubMed ID: 15794101
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy of volume and pressure delivery by mechanical ventilators in use in neonatal intensive care units: A quality control study.
    Ottaviani V; Veneroni C; Dell'Orto V; Lavizzari A; Ventura ML; Tossici M; Maroszynska I; Mosca F; Tagliabue P; De Luca D; Dellacà RL
    Pediatr Pulmonol; 2020 Aug; 55(8):1955-1962. PubMed ID: 32460445
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.
    Toyama H; Endo Y; Ejima Y; Matsubara M; Kurosawa S
    Anaesth Intensive Care; 2011 Jul; 39(4):599-606. PubMed ID: 21823376
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.
    Chen Y; Cheng K; Zhou X
    Med Sci Monit; 2015 Jan; 21():310-7. PubMed ID: 25619202
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Volume-targeted ventilation.
    Keszler M
    Early Hum Dev; 2006 Dec; 82(12):811-8. PubMed ID: 17069993
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Pressure and flow waveform characteristics of eight high-frequency oscillators.
    Harcourt ER; John J; Dargaville PA; Zannin E; Davis PG; Tingay DG
    Pediatr Crit Care Med; 2014 Jun; 15(5):e234-40. PubMed ID: 24717904
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system.
    Hentschel R; Semar N; Guttmann J
    Pediatr Crit Care Med; 2012 Sep; 13(5):560-7. PubMed ID: 22460774
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Initial mechanical ventilator settings for pediatric patients: clinical judgement in selection of tidal volume.
    Kanter RK; Blatt SD; Zimmerman JJ
    Am J Emerg Med; 1987 Mar; 5(2):113-7. PubMed ID: 3470010
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Accuracy of oscillatory pressure measured by mechanical ventilators during high frequency oscillatory ventilation in newborns.
    Veneroni C; Tossici M; Zannin E; Milesi I; Dellaca' RL
    Pediatr Pulmonol; 2018 Jul; 53(7):901-906. PubMed ID: 29746013
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Volume-Targeted Ventilation.
    Belteki G; Morley CJ
    Clin Perinatol; 2021 Dec; 48(4):825-841. PubMed ID: 34774211
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume.
    Al-Majed SI; Thompson JE; Watson KF; Randolph AG
    Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of tidal volume, compliance, and resistance measurements on neonatal ventilator displays: an in vitro assessment.
    Abbasi S; Sivieri E; Roberts R; Kirpalani H
    Pediatr Crit Care Med; 2012 Jul; 13(4):e262-8. PubMed ID: 22596072
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.