21. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study. Itagaki T; Bennett DJ; Chenelle CT; Fisher DF; Kacmarek RM Respir Care; 2017 Jan; 62(1):10-21. PubMed ID: 27879380 [TBL] [Abstract][Full Text] [Related]
22. The impact of closed endotracheal suctioning systems on mechanical ventilator performance. El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244 [TBL] [Abstract][Full Text] [Related]
23. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury. Custer JW; Watson CM; Dwyer J; Kaczka DW; Simon BA; Easley RB Pediatr Crit Care Med; 2011 Nov; 12(6):e357-61. PubMed ID: 21317679 [TBL] [Abstract][Full Text] [Related]
24. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator]. Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078 [TBL] [Abstract][Full Text] [Related]
25. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate? Chow LC; Vanderhal A; Raber J; Sola A Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848 [TBL] [Abstract][Full Text] [Related]
27. [Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode]. Imanaka H; Takeuchi M; Tachibana K; Takauchi Y; Inamori N; Nishimura M Masui; 2005 Mar; 54(3):254-9. PubMed ID: 15794101 [TBL] [Abstract][Full Text] [Related]
28. Accuracy of volume and pressure delivery by mechanical ventilators in use in neonatal intensive care units: A quality control study. Ottaviani V; Veneroni C; Dell'Orto V; Lavizzari A; Ventura ML; Tossici M; Maroszynska I; Mosca F; Tagliabue P; De Luca D; Dellacà RL Pediatr Pulmonol; 2020 Aug; 55(8):1955-1962. PubMed ID: 32460445 [TBL] [Abstract][Full Text] [Related]
29. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate. Ivanov VA Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200 [TBL] [Abstract][Full Text] [Related]
30. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators. Toyama H; Endo Y; Ejima Y; Matsubara M; Kurosawa S Anaesth Intensive Care; 2011 Jul; 39(4):599-606. PubMed ID: 21823376 [TBL] [Abstract][Full Text] [Related]
31. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study. Chen Y; Cheng K; Zhou X Med Sci Monit; 2015 Jan; 21():310-7. PubMed ID: 25619202 [TBL] [Abstract][Full Text] [Related]
32. Volume-targeted ventilation. Keszler M Early Hum Dev; 2006 Dec; 82(12):811-8. PubMed ID: 17069993 [TBL] [Abstract][Full Text] [Related]
33. Pressure and flow waveform characteristics of eight high-frequency oscillators. Harcourt ER; John J; Dargaville PA; Zannin E; Davis PG; Tingay DG Pediatr Crit Care Med; 2014 Jun; 15(5):e234-40. PubMed ID: 24717904 [TBL] [Abstract][Full Text] [Related]
34. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system. Hentschel R; Semar N; Guttmann J Pediatr Crit Care Med; 2012 Sep; 13(5):560-7. PubMed ID: 22460774 [TBL] [Abstract][Full Text] [Related]
35. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
36. Initial mechanical ventilator settings for pediatric patients: clinical judgement in selection of tidal volume. Kanter RK; Blatt SD; Zimmerman JJ Am J Emerg Med; 1987 Mar; 5(2):113-7. PubMed ID: 3470010 [TBL] [Abstract][Full Text] [Related]