166 related articles for article (PubMed ID: 34753618)
1. Accuracy of vital parameters measured by a wearable patch following major abdominal cancer surgery.
van der Stam JA; Mestrom EHJ; Scheerhoorn J; Jacobs F; de Hingh IHJT; van Riel NAW; Boer AK; Scharnhorst V; Nienhuijs SW; Bouwman RA
Eur J Surg Oncol; 2022 Apr; 48(4):917-923. PubMed ID: 34753618
[TBL] [Abstract][Full Text] [Related]
2. Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial.
Downey C; Ng S; Jayne D; Wong D
BMJ Open; 2019 Aug; 9(8):e031150. PubMed ID: 31420399
[TBL] [Abstract][Full Text] [Related]
3. Reliability of heart rate and respiration rate measurements with a wireless accelerometer in postbariatric recovery.
Jacobs F; Scheerhoorn J; Mestrom E; van der Stam J; Bouwman RA; Nienhuijs S
PLoS One; 2021; 16(4):e0247903. PubMed ID: 33909642
[TBL] [Abstract][Full Text] [Related]
4. The Accuracy of Wrist-Worn Photoplethysmogram-Measured Heart and Respiratory Rates in Abdominal Surgery Patients: Observational Prospective Clinical Validation Study.
van der Stam JA; Mestrom EHJ; Scheerhoorn J; Jacobs FENB; Nienhuijs S; Boer AK; van Riel NAW; de Morree HM; Bonomi AG; Scharnhorst V; Bouwman RA
JMIR Perioper Med; 2023 Feb; 6():e40474. PubMed ID: 36804173
[TBL] [Abstract][Full Text] [Related]
5. Vital Signs Monitoring with Wearable Sensors in High-risk Surgical Patients: A Clinical Validation Study.
Breteler MJM; KleinJan EJ; Dohmen DAJ; Leenen LPH; van Hillegersberg R; Ruurda JP; van Loon K; Blokhuis TJ; Kalkman CJ
Anesthesiology; 2020 Mar; 132(3):424-439. PubMed ID: 31743149
[TBL] [Abstract][Full Text] [Related]
6. Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting.
Kant N; Peters GM; Voorthuis BJ; Groothuis-Oudshoorn CGM; Koning MV; Witteman BPL; Rinia-Feenstra M; Doggen CJM
J Clin Monit Comput; 2022 Oct; 36(5):1449-1459. PubMed ID: 34878613
[TBL] [Abstract][Full Text] [Related]
7. A Chest Patch for Continuous Vital Sign Monitoring: Clinical Validation Study During Movement and Controlled Hypoxia.
Morgado Areia C; Santos M; Vollam S; Pimentel M; Young L; Roman C; Ede J; Piper P; King E; Gustafson O; Harford M; Shah A; Tarassenko L; Watkinson P
J Med Internet Res; 2021 Sep; 23(9):e27547. PubMed ID: 34524087
[TBL] [Abstract][Full Text] [Related]
8. Agreement between standard and continuous wireless vital sign measurements after major abdominal surgery: a clinical comparison study.
Haahr-Raunkjaer C; Skovbye M; Rasmussen SM; Elvekjaer M; Sørensen HBD; Meyhoff CS; Aasvang EK
Physiol Meas; 2022 Nov; 43(11):. PubMed ID: 36322987
[No Abstract] [Full Text] [Related]
9. Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study.
Breteler MJM; Huizinga E; van Loon K; Leenen LPH; Dohmen DAJ; Kalkman CJ; Blokhuis TJ
BMJ Open; 2018 Feb; 8(2):e020162. PubMed ID: 29487076
[TBL] [Abstract][Full Text] [Related]
10. A wearable patch based remote early warning score (REWS) in major abdominal cancer surgery patients.
van der Stam JA; Mestrom EHJ; Nienhuijs SW; de Hingh IHJT; Boer AK; van Riel NAW; de Groot KTJ; Verhaegh W; Scharnhorst V; Bouwman RA
Eur J Surg Oncol; 2023 Jan; 49(1):278-284. PubMed ID: 36085116
[TBL] [Abstract][Full Text] [Related]
11. A Wearable System with Embedded Conductive Textiles and an IMU for Unobtrusive Cardio-Respiratory Monitoring.
Di Tocco J; Raiano L; Sabbadini R; Massaroni C; Formica D; Schena E
Sensors (Basel); 2021 Apr; 21(9):. PubMed ID: 33923071
[TBL] [Abstract][Full Text] [Related]
12. Clinical evaluation of a wearable sensor for mobile monitoring of respiratory rate on hospital wards.
Järvelä K; Takala P; Michard F; Vikatmaa L
J Clin Monit Comput; 2022 Feb; 36(1):81-86. PubMed ID: 34476669
[TBL] [Abstract][Full Text] [Related]
13. Are current wireless monitoring systems capable of detecting adverse events in high-risk surgical patients? A descriptive study.
Breteler MJM; KleinJan E; Numan L; Ruurda JP; Van Hillegersberg R; Leenen LPH; Hermans M; Kalkman CJ; Blokhuis TJ
Injury; 2020 May; 51 Suppl 2():S97-S105. PubMed ID: 31761422
[TBL] [Abstract][Full Text] [Related]
14. Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor.
Huang N; Zhou M; Bian D; Mehta P; Shah M; Rajput KS; Selvaraj N
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7470-7475. PubMed ID: 34892821
[TBL] [Abstract][Full Text] [Related]
15. Continuous Monitoring of Vital Signs With Wearable Sensors During Daily Life Activities: Validation Study.
Haveman ME; van Rossum MC; Vaseur RME; van der Riet C; Schuurmann RCL; Hermens HJ; de Vries JPM; Tabak M
JMIR Form Res; 2022 Jan; 6(1):e30863. PubMed ID: 34994703
[TBL] [Abstract][Full Text] [Related]
16. Comparison between Chest-Worn Accelerometer and Gyroscope Performance for Heart Rate and Respiratory Rate Monitoring.
Romano C; Schena E; Formica D; Massaroni C
Biosensors (Basel); 2022 Oct; 12(10):. PubMed ID: 36290971
[TBL] [Abstract][Full Text] [Related]
17. Agreement between wireless and standard measurements of vital signs in acute exacerbation of chronic obstructive pulmonary disease: a clinical validation study.
Elvekjaer M; Carlsson CJ; Rasmussen SM; Porsbjerg CM; Grønbæk KK; Haahr-Raunkjær C; Sørensen HBD; Aasvang EK; Meyhoff CS
Physiol Meas; 2021 Jun; 42(5):. PubMed ID: 33984846
[No Abstract] [Full Text] [Related]
18. Contactless monitoring of respiratory rate (RR) and heart rate (HR) in non-acuity settings: a clinical validity study.
Varma M; Sequeira T; Naidu NKS; Mallya Y; Sunkara A; Patil P; Poojary N; Vaidyanathan MK; Balmaekers B; Thomas J; Prasad N S; Badagabettu S
BMJ Open; 2022 Dec; 12(12):e065790. PubMed ID: 36564107
[TBL] [Abstract][Full Text] [Related]
19. A Wireless Wearable Patch for Remote Monitoring of Respiratory and Cardiac Rhythm in Children.
Javed F; Sanchez JC; MacLean S; Lam V; O'Flynn L; Tanverdi M; Liu AH
Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083154
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study.
Nelson BW; Allen NB
JMIR Mhealth Uhealth; 2019 Mar; 7(3):e10828. PubMed ID: 30855232
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]