61. Comparison of the Application of Vibrating Mesh Nebulizer and Jet Nebulizer in Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-analysis. Feng Z; Han Z; Wang Y; Guo H; Liu J Int J Chron Obstruct Pulmon Dis; 2024; 19():829-839. PubMed ID: 38562440 [TBL] [Abstract][Full Text] [Related]
62. Quantifying Aerosol Delivery in Simulated Spontaneously Breathing Patients With Tracheostomy Using Different Humidification Systems With or Without Exhaled Humidity. Ari A; Harwood R; Sheard M; Alquaimi MM; Alhamad B; Fink JB Respir Care; 2016 May; 61(5):600-6. PubMed ID: 26908921 [TBL] [Abstract][Full Text] [Related]
63. In vitro comparison of unit dose vs infusion pump administration of albuterol via high-flow nasal cannula in toddlers. Li J; Wei W; Fink JB Pediatr Pulmonol; 2020 Feb; 55(2):322-329. PubMed ID: 31782914 [TBL] [Abstract][Full Text] [Related]
64. Effect of face mask design on inhaled mass of nebulized albuterol, using a pediatric breathing model. Lin HL; Restrepo RD; Gardenhire DS; Rau JL Respir Care; 2007 Aug; 52(8):1021-6. PubMed ID: 17650358 [TBL] [Abstract][Full Text] [Related]
66. Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study. Sutherasan Y; Ball L; Raimondo P; Caratto V; Sanguineti E; Costantino F; Ferretti M; Kacmarek RM; Pelosi P BMC Pulm Med; 2017 Jan; 17(1):9. PubMed ID: 28068958 [TBL] [Abstract][Full Text] [Related]
67. Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model. Alhamad BR; Fink JB; Harwood RJ; Sheard MM; Ari A Respir Care; 2015 Jul; 60(7):1026-32. PubMed ID: 25737572 [TBL] [Abstract][Full Text] [Related]
68. Comparison of drug delivery from conventional versus "Venturi" nebulizers. Devadason SG; Everard ML; Linto JM; Le Souëf PN Eur Respir J; 1997 Nov; 10(11):2479-83. PubMed ID: 9426082 [TBL] [Abstract][Full Text] [Related]
69. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation. Ari A; Atalay OT; Harwood R; Sheard MM; Aljamhan EA; Fink JB Respir Care; 2010 Jul; 55(7):845-51. PubMed ID: 20587095 [TBL] [Abstract][Full Text] [Related]
70. Effect of a Nebulizer Holding Chamber on Aerosol Delivery. Sarhan RM; Elberry AA; Abdelwahab NS; Rabea H; Salem MN; Abdelrahim ME Respir Care; 2018 Sep; 63(9):1125-1131. PubMed ID: 29789412 [TBL] [Abstract][Full Text] [Related]
71. Effect of face mask dead volume, respiratory rate, and tidal volume on inhaled albuterol delivery. Chavez A; McCracken A; Berlinski A Pediatr Pulmonol; 2010 Mar; 45(3):224-9. PubMed ID: 20146371 [TBL] [Abstract][Full Text] [Related]
72. Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model. Berlinski A; Willis JR Respir Care; 2013 Jul; 58(7):1124-33. PubMed ID: 23107173 [TBL] [Abstract][Full Text] [Related]
73. In vitro comparison of five nebulizers during noninvasive ventilation: analysis of inhaled and lost doses. Michotte JB; Jossen E; Roeseler J; Liistro G; Reychler G J Aerosol Med Pulm Drug Deliv; 2014 Dec; 27(6):430-40. PubMed ID: 24517084 [TBL] [Abstract][Full Text] [Related]
74. In vitro performance of spacers for aerosol delivery during adult mechanical ventilation. Boukhettala N; Porée T; Diot P; Vecellio L J Aerosol Med Pulm Drug Deliv; 2015 Apr; 28(2):130-6. PubMed ID: 25050644 [TBL] [Abstract][Full Text] [Related]
75. Facemask design, facial deposition, and delivered dose of nebulized aerosols. Smaldone GC; Sangwan S; Shah A J Aerosol Med; 2007; 20 Suppl 1():S66-75; discussion S75-7. PubMed ID: 17411408 [TBL] [Abstract][Full Text] [Related]
76. Comparison of Vibrating Mesh and Jet Nebulizers During Noninvasive Ventilation in Acute Exacerbation of Chronic Obstructive Pulmonary Disease. Avdeev SN; Nuralieva GS; Soe AK; Gainitdinova VV; Fink JB J Aerosol Med Pulm Drug Deliv; 2021 Dec; 34(6):358-365. PubMed ID: 33848441 [No Abstract] [Full Text] [Related]
77. Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation. ElHansy MHE; Boules ME; El Essawy AFM; Al-Kholy MB; Abdelrahman MM; Said ASA; Hussein RRS; Abdelrahim ME Pulm Pharmacol Ther; 2017 Aug; 45():159-163. PubMed ID: 28627376 [TBL] [Abstract][Full Text] [Related]
78. Influences of cannula size and flow rate on aerosol drug delivery through the Vapotherm humidified high-flow nasal cannula system. Perry SA; Kesser KC; Geller DE; Selhorst DM; Rendle JK; Hertzog JH Pediatr Crit Care Med; 2013 Jun; 14(5):e250-6. PubMed ID: 23628834 [TBL] [Abstract][Full Text] [Related]
79. Deposition of albuterol aerosol generated by pneumatic nebulizer in the Sophia Anatomical Infant Nose-Throat (SAINT) model. Laube BL; Sharpless G; Shermer C; Nasir O; Sullivan V; Powell K Pharm Res; 2010 Aug; 27(8):1722-9. PubMed ID: 20496045 [TBL] [Abstract][Full Text] [Related]