BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 34774998)

  • 1. Dosimetric Planning Tradeoffs to Reduce Heart Dose Using Machine Learning-Guided Decision Support Software in Patients with Lung Cancer.
    Bitterman DS; Selesnick P; Bredfeldt J; Williams CL; Guthier C; Huynh E; Kozono DE; Lewis JH; Cormack RA; Carpenter CM; Mak RH; Atkins KM
    Int J Radiat Oncol Biol Phys; 2022 Mar; 112(4):996-1003. PubMed ID: 34774998
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Potential for reduced toxicity and dose escalation in the treatment of inoperable non-small-cell lung cancer: a comparison of intensity-modulated radiation therapy (IMRT), 3D conformal radiation, and elective nodal irradiation.
    Grills IS; Yan D; Martinez AA; Vicini FA; Wong JW; Kestin LL
    Int J Radiat Oncol Biol Phys; 2003 Nov; 57(3):875-90. PubMed ID: 14529795
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A potential to reduce pulmonary toxicity: the use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer.
    Lavrenkov K; Christian JA; Partridge M; Niotsikou E; Cook G; Parker M; Bedford JL; Brada M
    Radiother Oncol; 2007 May; 83(2):156-62. PubMed ID: 17493699
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose distribution and tumor control probability in out-of-field lymph node stations in intensity modulated radiotherapy (IMRT) vs 3D-conformal radiotherapy (3D-CRT) of non-small-cell lung cancer: an in silico analysis.
    Fleckenstein J; Eschler A; Kremp K; Kremp S; RĂ¼be C
    Radiat Oncol; 2015 Aug; 10():178. PubMed ID: 26292716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Regression models for predicting physical and EQD
    Wang H; Zhou Y; Gan W; Chen H; Huang Y; Duan Y; Feng A; Shao Y; Gu H; Kong Q; Xu Z
    Radiat Oncol; 2021 Jun; 16(1):119. PubMed ID: 34176503
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT).
    Jiang X; Li T; Liu Y; Zhou L; Xu Y; Zhou X; Gong Y
    Radiat Oncol; 2011 Oct; 6():140. PubMed ID: 22014217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer.
    Meng LL; Feng LC; Wang YL; Dai XK; Xie CB
    Chin Med J (Engl); 2011 Jun; 124(11):1667-71. PubMed ID: 21740774
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetric definitions of total lung volumes in calculating parameters predictive for radiation-induced pneumonitis.
    Kabolizadeh P; Kalash R; Huq MS; Greenberger JS; Heron DE; Beriwal S
    Am J Clin Oncol; 2015 Aug; 38(4):401-4. PubMed ID: 24064747
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cardiac and Pulmonary Dosimetric Parameters in Patients With Lung Cancer Undergoing Postoperative Radiation Therapy Across a Statewide Consortium.
    Herr DJ; Yin H; Allen SG; Bergsma D; Dragovic AF; Dess RT; Matuszak M; Grubb M; Dominello M; Movsas B; Kestin LL; Hayman JA; Paximadis P; Schipper M; Jolly S;
    Pract Radiat Oncol; 2023; 13(3):e254-e260. PubMed ID: 36754278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Superiority of conventional intensity-modulated radiotherapy over helical tomotherapy in locally advanced non-small cell lung cancer. A comparative plan analysis.
    Song C; Pyo H; Kim J; Lim YK; Kim WC; Kim HJ; Kim DW; Cho KH
    Strahlenther Onkol; 2012 Oct; 188(10):901-9. PubMed ID: 22895625
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in-silico comparison of proton beam and IMRT for postoperative radiotherapy in completely resected stage IIIA non-small cell lung cancer.
    Berman AT; Teo BK; Dolney D; Swisher-McClure S; Shahnazi K; Both S; Rengan R
    Radiat Oncol; 2013 Jun; 8():144. PubMed ID: 23767810
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fully automated VMAT treatment planning for advanced-stage NSCLC patients.
    Della Gala G; Dirkx MLP; Hoekstra N; Fransen D; Lanconelli N; van de Pol M; Heijmen BJM; Petit SF
    Strahlenther Onkol; 2017 May; 193(5):402-409. PubMed ID: 28314877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reducing the low-dose lung radiation for central lung tumors by restricting the IMRT beams and arc arrangement.
    Rosca F; Kirk M; Soto D; Sall W; McIntyre J
    Med Dosim; 2012; 37(3):280-6. PubMed ID: 22189028
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical application of a novel hybrid intensity-modulated radiotherapy technique for stage III lung cancer and dosimetric comparison with four other techniques.
    Verbakel WF; van Reij E; Ladenius-Lischer I; Cuijpers JP; Slotman BJ; Senan S
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):e297-303. PubMed ID: 22579380
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Functional lung avoidance and response-adaptive escalation (FLARE) RT: Multimodality plan dosimetry of a precision radiation oncology strategy.
    Lee E; Zeng J; Miyaoka RS; Saini J; Kinahan PE; Sandison GA; Wong T; Vesselle HJ; Rengan R; Bowen SR
    Med Phys; 2017 Jul; 44(7):3418-3429. PubMed ID: 28453861
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
    Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
    J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of dose calculation accuracy during optimization on lung IMRT plan quality.
    Li Y; Rodrigues A; Li T; Yuan L; Yin FF; Wu QJ
    J Appl Clin Med Phys; 2015 Jan; 16(1):5137. PubMed ID: 25679172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of inverse-planned three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for non-small-cell lung cancer.
    Christian JA; Bedford JL; Webb S; Brada M
    Int J Radiat Oncol Biol Phys; 2007 Mar; 67(3):735-41. PubMed ID: 17187941
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility of radical cardiac-sparing, treatment planning strategies for patients with locally advanced, non-small cell lung cancer.
    Kim JP; Dewalt J; Feldman A; Adil K; Movsas B; Chetty IJ
    J Appl Clin Med Phys; 2022 Dec; 23(12):e13784. PubMed ID: 36237114
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of intensity-modulated radiation therapy as a boost treatment on the lung-dose distributions for non-small-cell lung cancer.
    Choi Y; Kim JK; Lee HS; Hur WJ; Chai GY; Kang KM
    Int J Radiat Oncol Biol Phys; 2005 Nov; 63(3):683-9. PubMed ID: 15927412
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.