207 related articles for article (PubMed ID: 34779179)
1. [Research progress on comparison of the application effects between personal specific instrumentation and computer-assisted navigation surgery in total knee arthroplasty].
Dong Z; Li Y; Tian H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Nov; 35(11):1492-1498. PubMed ID: 34779179
[TBL] [Abstract][Full Text] [Related]
2. [Comparison of alignment between computer assisted surgery and personal specific instrumentation in total knee arthroplasty].
Wang XG; Li Y; He YZ; Wu TC; Tian H
Zhonghua Yi Xue Za Zhi; 2021 Dec; 101(47):3850-3856. PubMed ID: 34905884
[No Abstract] [Full Text] [Related]
3. Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.
Tandogan RN; Kort NP; Ercin E; van Rooij F; Nover L; Saffarini M; Hirschmann MT; Becker R; Dejour D;
Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2654-2665. PubMed ID: 33646370
[TBL] [Abstract][Full Text] [Related]
4. [Effect of the surgical time and coronalmechanical alignment after total knee arthroplasty using computer navigation system, traditionalor 3D printing patient-specific instruments].
Li Y; Tian H; Geng X
Zhonghua Yi Xue Za Zhi; 2018 Jul; 98(27):2157-2161. PubMed ID: 30032517
[No Abstract] [Full Text] [Related]
5. [Early effectiveness of computer navigation-assisted total knee arthroplasty].
Sun H; Zheng K; Zhang W; Li N; Zhang L; Zhou J; Xu Y; Li R
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Oct; 35(10):1273-1280. PubMed ID: 34651480
[TBL] [Abstract][Full Text] [Related]
6. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting.
Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E
Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634
[TBL] [Abstract][Full Text] [Related]
7. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty.
Laende EK; Richardson CG; Dunbar MJ
Bone Joint J; 2019 Aug; 101-B(8):929-940. PubMed ID: 31362561
[TBL] [Abstract][Full Text] [Related]
8. [Blood loss in total knee arthroplasty using computer-assisted navigation or 3D-printed patient-specific instruments].
Li Y; Geng X; Tian H; Tao LY
Zhonghua Yi Xue Za Zhi; 2020 Sep; 100(33):2601-2606. PubMed ID: 32892606
[No Abstract] [Full Text] [Related]
9. [Effect of femoral component rotational alignment in total knee arthroplasty by using 3D-printed patient-specific instruments: a prospective randomized control study].
Li Y; Wang XG; Tian H; Tao LY
Zhonghua Yi Xue Za Zhi; 2021 Sep; 101(35):2766-2771. PubMed ID: 34551492
[No Abstract] [Full Text] [Related]
10. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
Russell R; Brown T; Huo M; Jones R
J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
[TBL] [Abstract][Full Text] [Related]
11. [Effects of iASSIST navigation system and personal specific instrument assisted total knee arthroplasty in the treatment of osteoarthritis].
Tian SC; Yao QQ; Yin XD; Liu S; Zhou J; Hu J; Li JY; Shan R; Jiang HB; Wang LM
Zhonghua Wai Ke Za Zhi; 2017 Jun; 55(6):423-429. PubMed ID: 28592074
[No Abstract] [Full Text] [Related]
12. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
[TBL] [Abstract][Full Text] [Related]
13. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.
Gong S; Xu W; Wang R; Wang Z; Wang B; Han L; Chen G
Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1083-1095. PubMed ID: 30377714
[TBL] [Abstract][Full Text] [Related]
14. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.
Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H
Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377
[TBL] [Abstract][Full Text] [Related]
15. Postoperative radiologic outcome comparison between conventional and computer-assisted navigation total knee arthroplasty in extra-articular tibia vara.
Cho Y; Shin HK; Kim E; Park JH; Park SJ; Jang T; Jeong HJ
J Orthop Surg (Hong Kong); 2020; 28(1):2309499020905702. PubMed ID: 32114895
[TBL] [Abstract][Full Text] [Related]
16. Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.
Yaffe M; Luo M; Goyal N; Chan P; Patel A; Cayo M; Stulberg SD
Int J Comput Assist Radiol Surg; 2014 Sep; 9(5):837-44. PubMed ID: 24337791
[TBL] [Abstract][Full Text] [Related]
17. A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty.
MacDessi SJ; Jang B; Harris IA; Wheatley E; Bryant C; Chen DB
Knee; 2014 Mar; 21(2):406-9. PubMed ID: 24378337
[TBL] [Abstract][Full Text] [Related]
18. Patient-specific instrumentation in total knee arthroplasty.
León-Muñoz VJ; Martínez-Martínez F; López-López M; Santonja-Medina F
Expert Rev Med Devices; 2019 Jul; 16(7):555-567. PubMed ID: 31154870
[TBL] [Abstract][Full Text] [Related]
19. The influence of computer-assisted surgery on rotational, coronal and sagittal alignment in revision total knee arthroplasty.
Meijer MF; Stevens M; Boerboom AL; Bulstra SK; Reininga IH
BMC Musculoskelet Disord; 2014 Mar; 15():94. PubMed ID: 24646028
[TBL] [Abstract][Full Text] [Related]
20. 2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study.
Kim YH; Park JW; Kim JS
Clin Orthop Relat Res; 2018 Jan; 476(1):6-15. PubMed ID: 29389753
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]