These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 34787715)

  • 41. Effect of audiological testing on programmable ventriculoperitoneal shunts.
    Abdul-Hamid A; Zilani G; Bryant C; Bryant A; Qureishi A; Jeyaretna S; MacKeith S
    Int J Audiol; 2022 Feb; 61(2):173-176. PubMed ID: 33586553
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Lumboperitoneal Shunt: A New Modified Surgical Technique and a Comparison of the Complications with Ventriculoperitoneal Shunt in a Single Center.
    Yang TH; Chang CS; Sung WW; Liu JT
    Medicina (Kaunas); 2019 Sep; 55(10):. PubMed ID: 31561485
    [No Abstract]   [Full Text] [Related]  

  • 43. What is the ideal initial valve pressure setting in neonates with ventriculoperitoneal shunts?
    Korinth MC; Gilsbach JM
    Pediatr Neurosurg; 2002 Apr; 36(4):169-74. PubMed ID: 12006750
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Silver-impregnated, antibiotic-impregnated or non-impregnated ventriculoperitoneal shunts to prevent shunt infection: the BASICS three-arm RCT.
    Mallucci CL; Jenkinson MD; Conroy EJ; Hartley JC; Brown M; Moitt T; Dalton J; Kearns T; Griffiths MJ; Culeddu G; Solomon T; Hughes D; Gamble C;
    Health Technol Assess; 2020 Mar; 24(17):1-114. PubMed ID: 32238262
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Pressure changes observed in Codman-Medos programmable valves following magnetic exposure and filliping.
    Miwa K; Kondo H; Sakai N
    Childs Nerv Syst; 2001 Feb; 17(3):150-3. PubMed ID: 11305768
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Programmable shunt valves: in vitro assessment of safety of the magnetic field generated by a portable game machine.
    Nakashima K; Nakajo T; Kawamo M; Kato A; Ishigaki S; Murakami H; Imaizumi Y; Izumiyama H
    Neurol Med Chir (Tokyo); 2011; 51(9):635-8. PubMed ID: 21946726
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Magnetic resonance-based estimation of intracranial pressure correlates with ventriculoperitoneal shunt valve opening pressure setting in children with hydrocephalus.
    Muehlmann M; Koerte IK; Laubender RP; Steffinger D; Lehner M; Peraud A; Heinen F; Kiefer M; Reiser M; Ertl-Wagner B
    Invest Radiol; 2013 Jul; 48(7):543-7. PubMed ID: 23695081
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The Burden of Ionizing Radiation Studies in Children with Ventricular Shunts.
    Antonucci MC; Zuckerbraun NS; Tyler-Kabara EC; Furtado AD; Murphy ME; Marin JR
    J Pediatr; 2017 Mar; 182():210-216.e1. PubMed ID: 27989409
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Programmable shunt valve affected by exposure to a tablet computer.
    Strahle J; Selzer BJ; Muraszko KM; Garton HJ; Maher CO
    J Neurosurg Pediatr; 2012 Aug; 10(2):118-20. PubMed ID: 22734456
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Choice of valve type and poor ventricular catheter placement: Modifiable factors associated with ventriculoperitoneal shunt failure.
    Jeremiah KJ; Cherry CL; Wan KR; Toy JA; Wolfe R; Danks RA
    J Clin Neurosci; 2016 May; 27():95-8. PubMed ID: 26758704
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Long-term follow-up and comparison of programmable and non-programmable ventricular cerebrospinal fluid shunts among adult patients with different hydrocephalus etiologies: a retrospective cohort study.
    Chen KH; Hsu PW; Wu BC; Tu PH; Wang YC; Lee CC; Huang YC; Chen CC; Chuang CC; Liu ZH
    Acta Neurochir (Wien); 2023 Sep; 165(9):2551-2560. PubMed ID: 37553445
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Four-year experience with the routine use of the programmable Hakim valve in the management of children with hydrocephalus.
    Rohde V; Mayfrank L; Ramakers VT; Gilsbach JM
    Acta Neurochir (Wien); 1998; 140(11):1127-34. PubMed ID: 9870057
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Adjustable cerebrospinal fluid shunt valves in 3.0-Tesla MRI: a phantom study using explanted devices.
    Akbar M; Aschoff A; Georgi JC; Nennig E; Heiland S; Abel R; Stippich C
    Rofo; 2010 Jul; 182(7):594-602. PubMed ID: 20563954
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Maladjustment of programmable ventricular shunt valves by inadvertent exposure to a common hospital device.
    Fujimura R; Lober R; Kamian K; Kleiner L
    Surg Neurol Int; 2018; 9():51. PubMed ID: 29576902
    [TBL] [Abstract][Full Text] [Related]  

  • 55. In vitro testing of explanted shunt valves in hydrocephalic patients with suspected valve malfunction.
    Bettag C; von der Brelie C; Freimann FB; Thomale UW; Rohde V; Fiss I
    Neurosurg Rev; 2022 Feb; 45(1):571-583. PubMed ID: 34027574
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Experience with a programmable valve shunt system.
    Yamashita N; Kamiya K; Yamada K
    J Neurosurg; 1999 Jul; 91(1):26-31. PubMed ID: 10389876
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients.
    Zemack G; Romner B
    J Neurosurg; 2000 Jun; 92(6):941-8. PubMed ID: 10839253
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison of programmable shunt valves vs standard valves for communicating hydrocephalus of adults: a retrospective analysis of 407 patients.
    Ringel F; Schramm J; Meyer B
    Surg Neurol; 2005 Jan; 63(1):36-41; discussion 41. PubMed ID: 15639519
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The delta valve: how does its clinical performance compare with two other pressure differential valves without antisiphon control?
    Davis SE; Levy ML; McComb JG; Sposto R
    Pediatr Neurosurg; 2000 Aug; 33(2):58-63. PubMed ID: 11070430
    [TBL] [Abstract][Full Text] [Related]  

  • 60. An adjustable gravitational valve for initial VP-shunt treatment in hydrocephalic preterm neonates and infants below 1 year of age.
    Bock HC; von Philipp G; Ludwig HC
    Childs Nerv Syst; 2021 Nov; 37(11):3497-3507. PubMed ID: 34152450
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.