These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 34791451)
21. An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty. Phillips FM; Todd Wetzel F; Lieberman I; Campbell-Hupp M Spine (Phila Pa 1976); 2002 Oct; 27(19):2173-8; discussion 2178-9. PubMed ID: 12394934 [TBL] [Abstract][Full Text] [Related]
22. What is wrong in the cava? A rare cause of deep vein thrombosis. Deylgat B; Van Holsbeeck B; Gellens P Vasc Endovascular Surg; 2009 Dec; 43(6):610-3. PubMed ID: 19640907 [TBL] [Abstract][Full Text] [Related]
23. Clinical Relevance of Cement Leakage after Radiofrequency Kyphoplasty vs. Balloon Kyphoplasty: A Prospective Randomised Study. Riesner HJ; Kiupel K; Lang P; Stuby F; Friemert B; Palm HG Z Orthop Unfall; 2016 Aug; 154(4):370-6. PubMed ID: 27336840 [TBL] [Abstract][Full Text] [Related]
24. Severe Pulmonary Embolism was Secondary to Cement Inferior Vena Cava Embolism after Percutaneous Vertebroplasty. Yuan Z; Zhou Y; Zhou X; Liao X Ann Vasc Surg; 2018 Apr; 48():255.e1-255.e3. PubMed ID: 29428532 [TBL] [Abstract][Full Text] [Related]
25. Cardiac Perforation and Multiple Emboli After Percutaneous Vertebroplasty. Shen C; Liu G; Hu JZ; Yang XH Orthopedics; 2015 Oct; 38(10):e947-50. PubMed ID: 26488794 [TBL] [Abstract][Full Text] [Related]
26. A rare nidus for pulmonary thromboembolism after vertebroplasty. Vallabhajosyula S; Sundaragiri PR; Bansal O; Townley TA BMJ Case Rep; 2013 Oct; 2013():. PubMed ID: 24154998 [TBL] [Abstract][Full Text] [Related]
27. [Partial thrombosis of the inferior vena cava in a patient with non-Hodgkin lymphoma and history of lumbar spine surgery]. Sun R; Maier B; Theilmann L; Abdel Samie A Internist (Berl); 2012 Apr; 53(4):474-7. PubMed ID: 22274303 [TBL] [Abstract][Full Text] [Related]
28. [Risk factors of non-surgical vertebral fracture after percutaneous kyphoplasty of single segment thoracolumbar fracture]. Wu J; Guan YH; Fan SL Zhongguo Gu Shang; 2017 Sep; 30(9):833-837. PubMed ID: 29455485 [TBL] [Abstract][Full Text] [Related]
29. A mysterious risk factor for bone cement leakage into the spinal canal through the Batson vein during percutaneous kyphoplasty: a case control study. Zhang S; Wang GJ; Wang Q; Yang J; Xu S; Yang CH BMC Musculoskelet Disord; 2019 Sep; 20(1):423. PubMed ID: 31510985 [TBL] [Abstract][Full Text] [Related]
30. [Mid-term follow-up and coping strategies of bone cement leakage after percutaneous kyphoplasty]. Sun QC; Ru XL; Song BS; Duanmu QL Zhongguo Gu Shang; 2017 Sep; 30(9):810-816. PubMed ID: 29455481 [TBL] [Abstract][Full Text] [Related]
31. [Vertebral internal reinforcement operation for the treatment of osteoporotic vertebral compressive fractures combined with bone cement leakage]. Dong G; Yue J; Zhou H; Xiang D Zhongguo Gu Shang; 2014 Jun; 27(6):504-7. PubMed ID: 25241472 [TBL] [Abstract][Full Text] [Related]
32. Ct of congenital anomalies of the inferior vena cava. Alexander ES; Clark RA; Gross BH; Colley DP Comput Radiol; 1982; 6(4):219-26. PubMed ID: 7140253 [TBL] [Abstract][Full Text] [Related]
33. Entrapped inferior vena cava between 2 lumbar vertebrae. Hwang SS; Park SY J Comput Assist Tomogr; 2009; 33(5):811-3. PubMed ID: 19820517 [TBL] [Abstract][Full Text] [Related]
34. Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws. Mueller JU; Baldauf J; Marx S; Kirsch M; Schroeder HW; Pillich DT J Neurosurg Spine; 2016 Jul; 25(1):103-9. PubMed ID: 26943258 [TBL] [Abstract][Full Text] [Related]
35. Early Complications and Cement Leakage in Elderly Patients Who Have Undergone Intraoperative Computed Tomography (CT)-Guided Cement Augmented Pedicle Screw Placement: Eight-Year Single-Center Experience. Ishak B; Bajwa AA; Schneider T; Tubbs RS; Iwanaga J; Ramey WL; Unterberg AW; Kiening KL World Neurosurg; 2019 Aug; 128():e975-e981. PubMed ID: 31100522 [TBL] [Abstract][Full Text] [Related]
37. Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. Kim YJ; Lee JW; Park KW; Yeom JS; Jeong HS; Park JM; Kang HS Radiology; 2009 Apr; 251(1):250-9. PubMed ID: 19332856 [TBL] [Abstract][Full Text] [Related]
38. Risk Factors for Cement Leakage in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures: An Analysis of 1456 Vertebrae Augmented by Low-Viscosity Bone Cement. Tang B; Cui L; Chen X; Liu Y Spine (Phila Pa 1976); 2021 Feb; 46(4):216-222. PubMed ID: 33156285 [TBL] [Abstract][Full Text] [Related]
39. Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body. Lin EP; Ekholm S; Hiwatashi A; Westesson PL AJNR Am J Neuroradiol; 2004 Feb; 25(2):175-80. PubMed ID: 14970015 [TBL] [Abstract][Full Text] [Related]
40. Cement leakage and the need for prophylactic fenestration of the spinal canal during vertebroplasty. Wenger M; Markwalder TM J Bone Joint Surg Am; 2002 Apr; 84(4):689; author reply 689-90. PubMed ID: 11940644 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]