189 related articles for article (PubMed ID: 34795014)
1. Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling.
Wang G; Nardo L; Parikh M; Abdelhafez YG; Li E; Spencer BA; Qi J; Jones T; Cherry SR; Badawi RD
J Nucl Med; 2022 Aug; 63(8):1274-1281. PubMed ID: 34795014
[TBL] [Abstract][Full Text] [Related]
2. First results on kinetic modelling and parametric imaging of dynamic
Sari H; Mingels C; Alberts I; Hu J; Buesser D; Shah V; Schepers R; Caluori P; Panin V; Conti M; Afshar-Oromieh A; Shi K; Eriksson L; Rominger A; Cumming P
Eur J Nucl Med Mol Imaging; 2022 May; 49(6):1997-2009. PubMed ID: 34981164
[TBL] [Abstract][Full Text] [Related]
3. Feasibility of using abbreviated scan protocols with population-based input functions for accurate kinetic modeling of [
Sari H; Eriksson L; Mingels C; Alberts I; Casey ME; Afshar-Oromieh A; Conti M; Cumming P; Shi K; Rominger A
Eur J Nucl Med Mol Imaging; 2023 Jan; 50(2):257-265. PubMed ID: 36192468
[TBL] [Abstract][Full Text] [Related]
4. Total-Body Quantitative Parametric Imaging of Early Kinetics of
Feng T; Zhao Y; Shi H; Li H; Zhang X; Wang G; Price PM; Badawi RD; Cherry SR; Jones T
J Nucl Med; 2021 May; 62(5):738-744. PubMed ID: 32948679
[TBL] [Abstract][Full Text] [Related]
5. Whole-Body Parametric Imaging of
Wu Y; Feng T; Zhao Y; Xu T; Fu F; Huang Z; Meng N; Li H; Shao F; Wang M
J Nucl Med; 2022 Apr; 63(4):622-628. PubMed ID: 34385335
[TBL] [Abstract][Full Text] [Related]
6. High-Temporal-Resolution Lung Kinetic Modeling Using Total-Body Dynamic PET with Time-Delay and Dispersion Corrections.
Wang Y; Spencer BA; Schmall J; Li E; Badawi RD; Jones T; Cherry SR; Wang G
J Nucl Med; 2023 Jul; 64(7):1154-1161. PubMed ID: 37116916
[TBL] [Abstract][Full Text] [Related]
7. Total-Body Multiparametric PET Quantification of
Wang Y; Nardo L; Spencer BA; Abdelhafez YG; Li EJ; Omidvari N; Chaudhari AJ; Badawi RD; Jones T; Cherry SR; Wang G
J Nucl Med; 2023 Nov; 64(11):1821-1830. PubMed ID: 37591539
[TBL] [Abstract][Full Text] [Related]
8. Efficient Delay Correction for Total-Body PET Kinetic Modeling Using Pulse Timing Methods.
Li EJ; Spencer BA; Schmall JP; Abdelhafez Y; Badawi RD; Wang G; Cherry SR
J Nucl Med; 2022 Aug; 63(8):1266-1273. PubMed ID: 34933888
[TBL] [Abstract][Full Text] [Related]
9. Quantitative studies using positron emission tomography (PET) for the diagnosis and therapy planning of oncological patients.
Dimitrakopoulou-Strauss A; Strauss L
Hell J Nucl Med; 2006; 9(1):10-21. PubMed ID: 16617388
[TBL] [Abstract][Full Text] [Related]
10. Accurate total-body K
Chen Z; Cheng Z; Duan Y; Zhang Q; Zhang N; Gu F; Wang Y; Zhou Y; Wang H; Liang D; Zheng H; Hu Z
Med Phys; 2023 Apr; 50(4):2121-2134. PubMed ID: 35950784
[TBL] [Abstract][Full Text] [Related]
11. Quantitative approaches of dynamic FDG-PET and PET/CT studies (dPET/CT) for the evaluation of oncological patients.
Dimitrakopoulou-Strauss A; Pan L; Strauss LG
Cancer Imaging; 2012 Sep; 12(1):283-9. PubMed ID: 23033440
[TBL] [Abstract][Full Text] [Related]
12. Comparison between a dual-time-window protocol and other simplified protocols for dynamic total-body
Wang Z; Wu Y; Li X; Bai Y; Chen H; Ding J; Shen C; Hu Z; Liang D; Liu X; Zheng H; Yang Y; Zhou Y; Wang M; Sun T
EJNMMI Phys; 2022 Sep; 9(1):63. PubMed ID: 36104580
[TBL] [Abstract][Full Text] [Related]
13. (18)F-alfatide II and (18)F-FDG dual-tracer dynamic PET for parametric, early prediction of tumor response to therapy.
Guo J; Guo N; Lang L; Kiesewetter DO; Xie Q; Li Q; Eden HS; Niu G; Chen X
J Nucl Med; 2014 Jan; 55(1):154-60. PubMed ID: 24232871
[TBL] [Abstract][Full Text] [Related]
14. Mapping
Wu Q; Gu F; O'Suilleabhain LD; Sari H; Xue S; Shi K; Rominger A; O'Sullivan F
J Nucl Med; 2024 Jun; 65(6):971-979. PubMed ID: 38604759
[TBL] [Abstract][Full Text] [Related]
15. Kinetic modeling and parametric imaging of
Yuan H; Zhang G; Sun T; Ren J; Zhang Q; Xiang Z; Liu E; Jiang L
Med Phys; 2024 Jan; 51(1):156-166. PubMed ID: 38043120
[TBL] [Abstract][Full Text] [Related]
16. First Total-Body Kinetic Modeling and Parametric Imaging of Dynamic
Chen R; Yang X; Ng YL; Yu X; Huo Y; Xiao X; Zhang C; Chen Y; Zheng C; Li L; Huang G; Zhou Y; Liu J
J Nucl Med; 2023 Jun; 64(6):960-967. PubMed ID: 36604180
[TBL] [Abstract][Full Text] [Related]
17. Abbreviated scan protocols to capture
Viswanath V; Sari H; Pantel AR; Conti M; Daube-Witherspoon ME; Mingels C; Alberts I; Eriksson L; Shi K; Rominger A; Karp JS
Eur J Nucl Med Mol Imaging; 2022 Jul; 49(9):3215-3225. PubMed ID: 35278108
[TBL] [Abstract][Full Text] [Related]
18. Quantitative accuracy of PET/CT for image-based kinetic analysis.
Seo Y; Teo BK; Hadi M; Schreck C; Bacharach SL; Hasegawa BH
Med Phys; 2008 Jul; 35(7):3086-9. PubMed ID: 18697532
[TBL] [Abstract][Full Text] [Related]
19. Parametric image generation with the uEXPLORER total-body PET/CT system through deep learning.
Huang Z; Wu Y; Fu F; Meng N; Gu F; Wu Q; Zhou Y; Yang Y; Liu X; Zheng H; Liang D; Wang M; Hu Z
Eur J Nucl Med Mol Imaging; 2022 Jul; 49(8):2482-2492. PubMed ID: 35312030
[TBL] [Abstract][Full Text] [Related]
20. The role of dynamic, static, and delayed total-body PET imaging in the detection and differential diagnosis of oncological lesions.
Wu Y; Fu F; Meng N; Wang Z; Li X; Bai Y; Zhou Y; Liang D; Zheng H; Yang Y; Wang M; Sun T
Cancer Imaging; 2024 Jan; 24(1):2. PubMed ID: 38167538
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]