These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 34797726)

  • 1. Neonatal digital chest radiography- should we be using additional copper filtration?
    Tugwell-Allsup JR; Morris RW; Thomas K; Hibbs R; England A
    Br J Radiol; 2022 Feb; 95(1130):20211026. PubMed ID: 34797726
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Copper filtration in pediatric digital X-ray imaging: its impact on image quality and dose.
    Brosi P; Stuessi A; Verdun FR; Vock P; Wolf R
    Radiol Phys Technol; 2011 Jul; 4(2):148-55. PubMed ID: 21431385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimising image quality and radiation dose for neonatal incubator imaging.
    Tugwell-Allsup J; Morris RW; Hibbs R; England A
    Radiography (Lond); 2020 Nov; 26(4):e258-e263. PubMed ID: 32279922
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of varying X-ray tube voltage and additional filtration on image quality and patient dose in digital radiography system.
    E A; A Y; T O
    Appl Radiat Isot; 2023 Sep; 199():110893. PubMed ID: 37321050
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of added filtration on radiation dose and image quality in digital radiography of newborns.
    Papadakis AE; Giannakaki V; Hatzidaki E; Damilakis J
    Pediatr Radiol; 2023 Sep; 53(10):2060-2068. PubMed ID: 37310445
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing the standard knee X-ray exposure factor, 10 kV rule, and modified 10 kV rule techniques in digital radiography to reduce patient radiation dose without loss of image quality.
    Wenman A; Lockwood P
    Radiography (Lond); 2024 Mar; 30(2):574-581. PubMed ID: 38295494
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluating the use of higher kVp and copper filtration as a dose optimisation tool in digital planar radiography.
    Mifsud K; Portelli JL; Zarb F; Couto JG
    Radiography (Lond); 2022 Aug; 28(3):586-592. PubMed ID: 35504239
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modification of chest radiography exposure parameters using a neonatal chest phantom.
    Schäfer SB; Papst S; Fiebich M; Rudolph C; de Laffolie J; Krombach GA
    Pediatr Radiol; 2020 Jan; 50(1):28-37. PubMed ID: 31583441
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimal beam quality for chest flat panel detector system: realistic phantom study.
    Kuwahara C; Aoki T; Oda N; Kawabata J; Sugimoto K; Kobayashi M; Fujii M; Korogi Y
    Eur Radiol; 2019 Sep; 29(9):4538-4543. PubMed ID: 30737566
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Potentials of additional copper filtration on radiation dose and image quality for adults underwent digital chest X-ray imaging in Dubai Health Authority - UAE.
    Siraj M; Dalah EZ; Okasha MH; Abdel Kader GI; Mohamed Said MS; Kalanter RA; Razack HA; Mohamad Ahmad AN; Albastaki AA
    Radiography (Lond); 2023 May; 29(3):552-556. PubMed ID: 36958232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: Initial experience with 3
    Hagelstein C; Henzler T; Haubenreisser H; Meyer M; Sudarski S; Schoenberg SO; Neff KW; Weis M
    Z Med Phys; 2016 Dec; 26(4):349-361. PubMed ID: 26702762
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Chest radiography with a flat-panel detector: image quality with dose reduction after copper filtration.
    Hamer OW; Sirlin CB; Strotzer M; Borisch I; Zorger N; Feuerbach S; Völk M
    Radiology; 2005 Nov; 237(2):691-700. PubMed ID: 16192324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimizing Contrast Resolution in Digital Chest Radiography by Varying Copper Filtration and kVp.
    Balac V; Grossman R; Griswold R; Bowman D
    Radiol Technol; 2023 Nov; 95(2):94-104. PubMed ID: 37940170
    [TBL] [Abstract][Full Text] [Related]  

  • 14. X-ray dose reduction using additional copper filtration for abdominal digital radiography: Evaluation using signal difference-to-noise ratio.
    Kawashima H; Ichikawa K; Nagasou D; Hattori M
    Phys Med; 2017 Feb; 34():65-71. PubMed ID: 28148466
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose optimization in newborn abdominal radiography: Assessing the added value of additional filtration on radiation dose and image quality using an anthropomorphic phantom.
    Petit AL; Alwan R; Behr J; Calame P; Lenoir M; Ducou le Pointe H; Delabrousse É
    Res Diagn Interv Imaging; 2024 Jun; 10():100045. PubMed ID: 39077732
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of contrast-to-noise ratio in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations.
    Doyle P; Martin CJ; Gentle D
    Phys Med Biol; 2006 Jun; 51(11):2953-70. PubMed ID: 16723777
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cu filtration for dose reduction in neonatal chest imaging.
    Smans K; Struelens L; Smet M; Bosmans H; Vanhavere F
    Radiat Prot Dosimetry; 2010; 139(1-3):281-6. PubMed ID: 20179072
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mobile chest imaging of neonates in incubators: Optimising DR and CR acquisitions.
    Tugwell-Allsup J; Kenworthy D; England A
    Radiography (Lond); 2021 Feb; 27(1):75-80. PubMed ID: 32636056
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system.
    Moore CS; Beavis AW; Saunderson JR
    Br J Radiol; 2008 Oct; 81(970):771-7. PubMed ID: 18662964
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pediatric thoracic CT angiography at 70 kV: a phantom study to investigate the effects on image quality and radiation dose.
    MacDougall RD; Kleinman PL; Yu L; Lee EY
    Pediatr Radiol; 2016 Jul; 46(8):1114-9. PubMed ID: 26987734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.