145 related articles for article (PubMed ID: 34798623)
21. Dosimetric verification of IMRT and 3D conformal treatment delivery using EPID.
Nasseri S; Bahreyni MH; Momennezhad M; Gholamhosseinian H; Shahedi F; Hashemi SM; Mohammadi M
Appl Radiat Isot; 2022 Apr; 182():110116. PubMed ID: 35092921
[TBL] [Abstract][Full Text] [Related]
22. A comparison of electronic portal dosimetry verification methods for use in stereotactic radiotherapy.
Millin AE; Windle RS; Lewis DG
Phys Med; 2016 Jan; 32(1):188-96. PubMed ID: 26748961
[TBL] [Abstract][Full Text] [Related]
23. A convolutional neural network model for EPID-based non-transit dosimetry.
Bosco LD; Franceries X; Romain B; Smekens F; Husson F; Le Lann MV
J Appl Clin Med Phys; 2023 Jun; 24(6):e13923. PubMed ID: 36864758
[TBL] [Abstract][Full Text] [Related]
24. Characterization of the a-Si EPID in the unity MR-linac for dosimetric applications.
Torres-Xirau I; Olaciregui-Ruiz I; Baldvinsson G; Mijnheer BJ; van der Heide UA; Mans A
Phys Med Biol; 2018 Jan; 63(2):025006. PubMed ID: 29182153
[TBL] [Abstract][Full Text] [Related]
25. Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine.
Zhu J; Chen L; Chen A; Luo G; Deng X; Liu X
Radiat Oncol; 2015 Apr; 10():85. PubMed ID: 25885567
[TBL] [Abstract][Full Text] [Related]
26. Assessment of beam-matched linacs quality/accuracy for interchanging SBRT or SRT patient using VMAT without replanning.
Xu Z; Warrell G; Lee S; Colussi V; Zheng Y; Ellis R; Machtay M; Podder T
J Appl Clin Med Phys; 2019 Jan; 20(1):68-75. PubMed ID: 30402983
[TBL] [Abstract][Full Text] [Related]
27. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
[TBL] [Abstract][Full Text] [Related]
28. Quantitative evaluation of 3D dosimetry for stereotactic volumetric-modulated arc delivery using COMPASS.
Vikraman S; Manigandan D; Karrthick KP; Sambasivaselli R; Senniandavar V; Ramu M; Rajesh T; Lutz M; Muthukumaran M; Karthikeyan N; Tejinder K
J Appl Clin Med Phys; 2014 Jan; 16(1):5128. PubMed ID: 25679152
[TBL] [Abstract][Full Text] [Related]
29. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning.
Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ
Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343
[TBL] [Abstract][Full Text] [Related]
30. Pretreatment verification of IMSRT using electronic portal imaging and Monte Carlo calculations.
Parker BC; Shiu A; White RA; Maor M; Dong L; Liu HH
Technol Cancer Res Treat; 2009 Dec; 8(6):413-23. PubMed ID: 19925025
[TBL] [Abstract][Full Text] [Related]
31. Remote dosimetric auditing of clinical trials: The need for vendor specific models to convert images to dose.
Miri N; Vial P; Greer PB
J Appl Clin Med Phys; 2019 Jan; 20(1):175-183. PubMed ID: 30597730
[TBL] [Abstract][Full Text] [Related]
32. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images.
van Elmpt WJ; Nijsten SM; Schiffeleers RF; Dekker AL; Mijnheer BJ; Lambin P; Minken AW
Med Phys; 2006 Jul; 33(7):2426-34. PubMed ID: 16898445
[TBL] [Abstract][Full Text] [Related]
33. Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry.
Pappas E; Kalaitzakis G; Boursianis T; Zoros E; Zourari K; Pappas EP; Makris D; Seimenis I; Efstathopoulos E; Maris TG
Phys Med Biol; 2019 Nov; 64(22):225009. PubMed ID: 31665709
[TBL] [Abstract][Full Text] [Related]
34. Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging.
Zwan BJ; Caillet V; Booth JT; Colvill E; Fuangrod T; O'Brien R; Briggs A; O'Connor DJ; Keall PJ; Greer PB
Med Phys; 2021 Mar; 48(3):953-964. PubMed ID: 33354787
[TBL] [Abstract][Full Text] [Related]
35. Towards real-time EPID-based 3D in vivo dosimetry for IMRT with Deep Neural Networks: A feasibility study.
Martins JC; Maier J; Gianoli C; Neppl S; Dedes G; Alhazmi A; Veloza S; Reiner M; Belka C; Kachelrieß M; Parodi K
Phys Med; 2023 Oct; 114():103148. PubMed ID: 37801811
[TBL] [Abstract][Full Text] [Related]
36. [Research on Position Verification of Multi-Leaf Collimator (MLC) and Dose Verification Based on Electronic Portal Imaging Device].
Sui J; Sun J; Xie K; Gao L; Lin T; Ni X
Zhongguo Yi Liao Qi Xie Za Zhi; 2024 Mar; 48(2):150-155. PubMed ID: 38605613
[TBL] [Abstract][Full Text] [Related]
37. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.
Wendling M; Louwe RJ; McDermott LN; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Feb; 33(2):259-73. PubMed ID: 16532930
[TBL] [Abstract][Full Text] [Related]
38. Measurement validation of treatment planning for a MR-Linac.
Chen X; Paulson ES; Ahunbay E; Sanli A; Klawikowski S; Li XA
J Appl Clin Med Phys; 2019 Jul; 20(7):28-38. PubMed ID: 31254376
[TBL] [Abstract][Full Text] [Related]
39. Validation of fluence-based 3D IMRT dose reconstruction on a heterogeneous anthropomorphic phantom using Monte Carlo simulation.
Nakaguchi Y; Ono T; Maruyama M; Nagasue N; Shimohigashi Y; Kai Y
J Appl Clin Med Phys; 2015 Jan; 16(1):5199. PubMed ID: 25679177
[TBL] [Abstract][Full Text] [Related]
40. Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization.
Cai B; Goddu SM; Yaddanapudi S; Caruthers D; Wen J; Noel C; Mutic S; Sun B
J Appl Clin Med Phys; 2018 Jan; 19(1):73-85. PubMed ID: 29125224
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]