312 related articles for article (PubMed ID: 34798850)
1. Impact of cement type and abutment height on pull-off force of zirconia reinforced lithium silicate crowns on titanium implant stock abutments: an in vitro study.
Müller L; Rauch A; Reissmann DR; Schierz O
BMC Oral Health; 2021 Nov; 21(1):592. PubMed ID: 34798850
[TBL] [Abstract][Full Text] [Related]
2. Pull-off Force of Four Different Implant Cements Between Zirconia Crowns and Titanium Implant Abutments in Two Different Abutment Heights.
Volkmann H; Rauch A; Koenig A; Schierz O
Int J Periodontics Restorative Dent; 2022; 42(3):e67-e74. PubMed ID: 35472113
[TBL] [Abstract][Full Text] [Related]
3. Fracture Resistance of Single-Unit Implant-Supported Crowns: Effects of Prosthetic Design and Restorative Material.
Donmez MB; Diken Turksayar AA; Olcay EO; Sahmali SM
J Prosthodont; 2022 Apr; 31(4):348-355. PubMed ID: 34383979
[TBL] [Abstract][Full Text] [Related]
4. Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area.
Carnaggio TV; Conrad R; Engelmeier RL; Gerngross P; Paravina R; Perezous L; Powers JM
J Prosthodont; 2012 Oct; 21(7):523-8. PubMed ID: 22469271
[TBL] [Abstract][Full Text] [Related]
5. Cemented Single Crown Retention on Dental Implants: An In Vitro Study.
Rues S; Fugina M; Rammelsberg P; Kappel S
Int J Prosthodont; 2017; 30(2):133-135. PubMed ID: 28267819
[TBL] [Abstract][Full Text] [Related]
6. In vitro assessment of the effect of luting agents, abutment height, and fatigue on the retention of zirconia crowns luted to titanium base implant abutments.
Strazzi-Sahyon HB; Bergamo ETP; Gierthmuehlen PC; Lopes ACO; Alves LMM; Benalcázar Jalkh EB; Zahoui A; Coelho PG; de Carvalho AM; Bonfante EA
J Prosthet Dent; 2023 Nov; 130(5):739.e1-739.e8. PubMed ID: 37684141
[TBL] [Abstract][Full Text] [Related]
7. Comparative evaluation of casting retention using the ITI solid abutment with six cements.
Mansour A; Ercoli C; Graser G; Tallents R; Moss M
Clin Oral Implants Res; 2002 Aug; 13(4):343-8. PubMed ID: 12175370
[TBL] [Abstract][Full Text] [Related]
8. Influence of abutment height and thermocycling on retrievability of cemented implant-supported crowns.
Mehl C; Harder S; Shahriari A; Steiner M; Kern M
Int J Oral Maxillofac Implants; 2012; 27(5):1106-15. PubMed ID: 23057023
[TBL] [Abstract][Full Text] [Related]
9. Influence of margin location and luting material on the amount of undetected cement excess on CAD/CAM implant abutments and cement-retained zirconia crowns: an in-vitro study.
Gehrke P; Bleuel K; Fischer C; Sader R
BMC Oral Health; 2019 Jun; 19(1):111. PubMed ID: 31200680
[TBL] [Abstract][Full Text] [Related]
10. Retentive strength of implant-supported CAD-CAM lithium disilicate crowns on zirconia custom abutments using 6 different cements.
Sellers K; Powers JM; Kiat-Amnuay S
J Prosthet Dent; 2017 Feb; 117(2):247-252. PubMed ID: 27677215
[TBL] [Abstract][Full Text] [Related]
11. Fatigue and Stress Distribution Analyses of Ceramic-Reinforced PEEK Abutments Restored with Monolithic Zirconia Crowns as an Alternative to Conventional Esthetic Abutments.
Akan E; Velioğlu E; Çömlekoğlu ME; Çömlekoğlu MD
Int J Oral Maxillofac Implants; 2022; 37(3):533-542. PubMed ID: 35727245
[TBL] [Abstract][Full Text] [Related]
12. The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restorations: A 3D finite element stress analysis.
Gökçimen G; Durkan R; Deste Gökay G; Oyar P
J Prosthodont; 2024 Jun; 33(5):497-505. PubMed ID: 37434476
[TBL] [Abstract][Full Text] [Related]
13. Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants.
Hanes B; Feitosa S; Phasuk K; Levon JA; Morton D; Lin WS
J Prosthodont; 2022 Jun; 31(5):441-446. PubMed ID: 34632673
[TBL] [Abstract][Full Text] [Related]
14. Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns.
Covey DA; Kent DK; St Germain HA; Koka S
J Prosthet Dent; 2000 Mar; 83(3):344-8. PubMed ID: 10709044
[TBL] [Abstract][Full Text] [Related]
15. Influence of abutment height and surface roughness on in vitro retention of three luting agents.
Cano-Batalla J; Soliva-Garriga J; Campillo-Funollet M; Munoz-Viveros CA; Giner-Tarrida L
Int J Oral Maxillofac Implants; 2012; 27(1):36-41. PubMed ID: 22299076
[TBL] [Abstract][Full Text] [Related]
16. Fracture Strength of Monolithic All-Ceramic Crowns on Titanium Implant Abutments.
Weyhrauch M; Igiel C; Scheller H; Weibrich G; Lehmann KM
Int J Oral Maxillofac Implants; 2016; 31(2):304-9. PubMed ID: 27004277
[TBL] [Abstract][Full Text] [Related]
17. Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.
Dähne F; Meißner H; Böning K; Arnold C; Gutwald R; Prause E
Int J Implant Dent; 2021 Jul; 7(1):62. PubMed ID: 34282495
[TBL] [Abstract][Full Text] [Related]
18. Effects of Cement, Abutment Surface Pretreatment, and Artificial Aging on the Force Required to Detach Cantilever Fixed Dental Prostheses from Dental Implants.
Kappel S; Chepura T; Schmitter M; Rammelsberg P; Rues S
Int J Prosthodont; 2017; 30(6):545–552. PubMed ID: 29084299
[TBL] [Abstract][Full Text] [Related]
19. Do strength of zirconia-abutment-interfaces depend on cement, zirconia type and titanium abutment dimensions?
Alic Z; Vaskovich T; Franz A; Lettner S; Moritz A; Watts DC; Schedle A
Dent Mater; 2024 Jun; 40(6):879-888. PubMed ID: 38734486
[TBL] [Abstract][Full Text] [Related]
20. Effect of CAD/CAM Abutment Height and Cement Type on the Retention of Zirconia Crowns.
Silva CEP; Soares S; Machado CM; Bergamo ETP; Coelho PG; Witek L; Ramalho IS; Jalkh EBB; Bonfante EA
Implant Dent; 2018 Oct; 27(5):582-587. PubMed ID: 30134265
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]