BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 34801246)

  • 1. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Injury; 2022 Feb; 53(2):353-361. PubMed ID: 34801246
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures.
    Zhang RY; Zhang WP; Yang GM; Wang DF; Su P; Zhang Y; Nie SB; Li J; Zhao Z; Li JT; Zhang LC; Tang PF
    Orthop Surg; 2024 Apr; 16(4):953-964. PubMed ID: 38389204
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The oblique triangle configuration of three parallel screws for femoral neck fracture fixation using computer-aided design modules.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Sci Rep; 2022 Jan; 12(1):325. PubMed ID: 35013408
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative biomechanical performance of two configurations of screw constructs and types used to stabilize different sites of unstable Pauwels type II femoral neck fractures: A finite element analysis.
    Chantarapanich N; Jitprapaikulsarn S; Mahaisavariya B; Mahaisavariya C
    Med Eng Phys; 2022 Sep; 107():103856. PubMed ID: 36068038
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.
    Wang J; Gao Y; Song D; Ni J
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2022 Aug; 47(8):1143-1153. PubMed ID: 36097783
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ideal Configuration Distribution of Femoral Neck Cannulated Screw in High Altitude Population: A Finite Element Study.
    Lei K; Li D; Ren R; Bai J; Qi Y; Zhang X
    Biomed Res Int; 2022; 2022():2085378. PubMed ID: 36337842
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Finite element analysis of optimal selection of cannulated threaded screw for the prevention of femoral neck shortening after internal fixation for femoral neck fracture].
    Chen ZM; Yang F; Yu S; Shi ZW; Yu X; Chen XJ; Shi L; Wang CH; Pang QJ
    Zhongguo Gu Shang; 2022 Nov; 35(11):1042-8. PubMed ID: 36415189
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures.
    Ma J; Zhao Z; Zhi X; Wang H; Wang W
    BMC Musculoskelet Disord; 2022 Nov; 23(1):1030. PubMed ID: 36447275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation.
    Li J; Wang M; Zhou J; Han L; Zhang H; Li C; Li L; Hao M
    Biomed Res Int; 2018; 2018():1271762. PubMed ID: 30627534
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures.
    Li J; Wang M; Li L; Zhang H; Hao M; Li C; Han L; Zhou J; Wang K
    J Orthop Surg Res; 2018 Oct; 13(1):272. PubMed ID: 30373617
    [TBL] [Abstract][Full Text] [Related]  

  • 11. How to choose the suitable FNS specification in young patients with femoral neck fracture: A finite element analysis.
    Fan Z; Huang Y; Su H; Jiang T
    Injury; 2021 Aug; 52(8):2116-2125. PubMed ID: 34154816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis.
    Lin S; Shang J; Xing B; Wu B; Peng R; Wang G; Lu HD
    BMC Musculoskelet Disord; 2021 Sep; 22(1):758. PubMed ID: 34488708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.
    Fan X; Zhou Y; Dai S; Lao K; Zhang Q; Yu T
    BMC Musculoskelet Disord; 2024 Jan; 25(1):83. PubMed ID: 38245678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Should cannulated screws be removed after a femoral neck fracture has healed, and how? A finite element analysis of the femur before and after cannulated screw removal.
    Wu L; Sun J; Fang N; Peng Q; Gao S; Liu L
    Int Orthop; 2022 Oct; 46(10):2393-2403. PubMed ID: 35852654
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures.
    Li J; Wang M; Zhou J; Zhang H; Li L
    Injury; 2020 Apr; 51(4):995-1003. PubMed ID: 32151421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.
    Huang BX; Zhan SZ; Yang M; Zhang DY
    BMC Musculoskelet Disord; 2023 Apr; 24(1):292. PubMed ID: 37059976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis.
    Zhong Z; Lan X; Xiang Z; Duan X
    Clin Biomech (Bristol, Avon); 2023 Aug; 108():106060. PubMed ID: 37536196
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation.
    Mei J; Liu S; Jia G; Cui X; Jiang C; Ou Y
    Injury; 2014 Dec; 45(12):2045-50. PubMed ID: 25172530
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture.
    Teng Y; Zhang Y; Guo C
    Medicine (Baltimore); 2022 Jul; 101(28):e29450. PubMed ID: 35839002
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis.
    Adamović P; Kodvanj J; Blažević D; Sabalić S
    Med Biol Eng Comput; 2023 May; 61(5):1005-1015. PubMed ID: 36640199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.