These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 3480342)

  • 21. Technical modification of the sagittal split mandibular ramus osteotomy.
    Loh FC
    Oral Surg Oral Med Oral Pathol; 1992 Dec; 74(6):723-6. PubMed ID: 1488226
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A modified technique to determine the desired length of bicortical screws in sagittal split osteotomies.
    Jovanovic A; Bouwman JP; Tuinzing DB
    J Oral Maxillofac Surg; 1996 Apr; 54(4):528-9. PubMed ID: 8600276
    [No Abstract]   [Full Text] [Related]  

  • 23. Technical improvements in the sagittal split ramus osteotomy.
    Niederdellmann H; Shetty V
    Oral Surg Oral Med Oral Pathol; 1989 Jan; 67(1):25-30. PubMed ID: 2911442
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new material (single crystal sapphire screw) for internal fixation of the mandibular ramus.
    Iizuka T; Fujimoto H; Ono T
    J Craniomaxillofac Surg; 1987 Feb; 15(1):24-7. PubMed ID: 3470312
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Protection of the lingual nerve during placement of rigid fixation after sagittal ramus osteotomy.
    Meyer RA
    J Oral Maxillofac Surg; 1990 Oct; 48(10):1135. PubMed ID: 2213305
    [No Abstract]   [Full Text] [Related]  

  • 26. Stability of skeletal class III malocclusion after combined maxillary and mandibular procedures: rigid internal fixation versus wire osteosynthesis of the mandible.
    Politi M; Costa F; Cian R; Polini F; Robiony M
    J Oral Maxillofac Surg; 2004 Feb; 62(2):169-81. PubMed ID: 14762749
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Functional stability of sagittal split ramus osteotomies: effects of positional screw size and placement configuration.
    Shetty V; Freymiller E; McBrearty D; Caputo AA
    J Oral Maxillofac Surg; 1996 May; 54(5):601-9: discussion 609-10. PubMed ID: 8632245
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Application of the condylar positioning appliance in mandibular sagittal split osteotomies with rigid skeletal fixation.
    Schwestka-Polly R; Engelke D; Kubein-Meesenburg D
    Int J Adult Orthodon Orthognath Surg; 1992; 7(1):15-21. PubMed ID: 1453035
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Lag screws in sagittal split osteotomies: should they be removed?
    Llewelyn J; Sugar A
    Br J Oral Maxillofac Surg; 1992 Apr; 30(2):83-6. PubMed ID: 1567808
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Postoperative stability after sagittal split ramus osteotomies for a mandibular setback with monocortical plate fixation or bicortical screw fixation.
    Chung IH; Yoo CK; Lee EK; Ihm JA; Park CJ; Lim JS; Hwang KG
    J Oral Maxillofac Surg; 2008 Mar; 66(3):446-52. PubMed ID: 18280376
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intraoral self-threading screw fixation for sagittal osteotomies: early experiences.
    Turvey TA; Hall DJ
    Int J Adult Orthodon Orthognath Surg; 1986; 1(4):243-50. PubMed ID: 3468177
    [No Abstract]   [Full Text] [Related]  

  • 32. Comparison of relapse in bilateral sagittal split osteotomies for mandibular advancement: rigid internal fixation (screws) versus inferior border wiring with anterior skeletal fixation.
    Moenning JE; Bussard DA; Lapp TH; Garrison BT
    Int J Adult Orthodon Orthognath Surg; 1990; 5(3):175-82. PubMed ID: 2098453
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading.
    Erkmen E; Simşek B; Yücel E; Kurt A
    Int J Oral Maxillofac Surg; 2005 Jul; 34(5):551-8. PubMed ID: 16053877
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Functionally stable tandem screw fixation in sagittal ramus osteotomy. Surgical technique, new instrumentation and experiences].
    Lindorf HH
    Dtsch Z Mund Kiefer Gesichtschir; 1984; 8(5):367-73. PubMed ID: 6597043
    [No Abstract]   [Full Text] [Related]  

  • 35. Three-dimensional Finite Element Analysis of Bone Fixation in Bilateral Sagittal Split Ramus Osteotomy Using Individual Models.
    Tamura N; Takaki T; Takano N; Shibahara T
    Bull Tokyo Dent Coll; 2018; 59(2):67-78. PubMed ID: 29962423
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stability after surgical-orthodontic correction of skeletal Class III malocclusion. I. Mandibular setback.
    Proffit WR; Phillips C; Dann C; Turvey TA
    Int J Adult Orthodon Orthognath Surg; 1991; 6(1):7-18. PubMed ID: 1940541
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparative study of skeletal stability between bicortical resorbable and titanium screw fixation after sagittal split ramus osteotomy for mandibular prognathism.
    Paeng JY; Hong J; Kim CS; Kim MJ
    J Craniomaxillofac Surg; 2012 Dec; 40(8):660-4. PubMed ID: 22209495
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Mechanical characteristics of the mandible after bilateral sagittal split ramus osteotomy: comparing 2 different fixation techniques.
    Chuong CJ; Borotikar B; Schwartz-Dabney C; Sinn DP
    J Oral Maxillofac Surg; 2005 Jan; 63(1):68-76. PubMed ID: 15635560
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Masticatory dysfunction with rigid and nonrigid osteosynthesis of sagittal split osteotomies.
    Timmis DP; Aragon SB; Van Sickels JE
    Oral Surg Oral Med Oral Pathol; 1986 Aug; 62(2):119-23. PubMed ID: 3462606
    [No Abstract]   [Full Text] [Related]  

  • 40. Experimental analysis of functional stability of sagittal split ramus osteotomies secured by miniplates and position screws.
    Shetty V; Freymiller E; McBrearty D; Caputo AA
    J Oral Maxillofac Surg; 1996 Nov; 54(11):1317-24; discussion 1324-6. PubMed ID: 8941183
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.