BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 34803552)

  • 21. Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study.
    Becher TH; Bui S; Zick G; Bläser D; Schädler D; Weiler N; Frerichs I
    Crit Care; 2014 Dec; 18(6):679. PubMed ID: 25492307
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients.
    Zhao Z; Lee LC; Chang MY; Frerichs I; Chang HT; Gow CH; Hsu YL; Möller K
    J Clin Monit Comput; 2020 Oct; 34(5):1005-1013. PubMed ID: 31587120
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Positive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve in severe acute respiratory distress syndrome.
    Zhao Z; Chang MY; Chang MY; Gow CH; Zhang JH; Hsu YL; Frerichs I; Chang HT; Möller K
    Ann Intensive Care; 2019 Jan; 9(1):7. PubMed ID: 30656479
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study.
    Heines SJH; de Jongh SAM; Strauch U; van der Horst ICC; van de Poll MCG; Bergmans DCJJ
    BMC Anesthesiol; 2022 Aug; 22(1):258. PubMed ID: 35971060
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile.
    Wirth S; Baur M; Spaeth J; Guttmann J; Schumann S
    Br J Anaesth; 2015 Mar; 114(3):483-90. PubMed ID: 25416274
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pronation Reveals a Heterogeneous Response of Global and Regional Respiratory Mechanics in Patients With Acute Hypoxemic Respiratory Failure.
    Morais CCA; Alcala G; De Santis Santiago RR; Valsecchi C; Diaz E; Wanderley H; Fakhr BS; Di Fenza R; Gianni S; Foote S; Chang MG; Bittner EA; Carroll RW; Costa ELV; Amato MBP; Berra L
    Crit Care Explor; 2023 Oct; 5(10):e0983. PubMed ID: 37795456
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of positive end-expiratory pressure on respiratory compliance in children with acute respiratory failure.
    Sivan Y; Deakers TW; Newth CJ
    Pediatr Pulmonol; 1991; 11(2):103-7. PubMed ID: 1758726
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prone positioning may increase lung overdistension in COVID-19-induced ARDS.
    Otáhal M; Mlček M; Borges JB; Alcala GC; Hladík D; Kuriščák E; Tejkl L; Amato M; Kittnar O
    Sci Rep; 2022 Oct; 12(1):16528. PubMed ID: 36192569
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Recruitability and effect of PEEP in SARS-Cov-2-associated acute respiratory distress syndrome.
    Beloncle FM; Pavlovsky B; Desprez C; Fage N; Olivier PY; Asfar P; Richard JC; Mercat A
    Ann Intensive Care; 2020 May; 10(1):55. PubMed ID: 32399901
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Determination of intrinsic PEEP during mechanical ventilation. Validation of a new optional method of measurement provided by the EVITA mechanical ventilator].
    Sydow M; Denecke T; Zinserling J; Zielmann S; Crozier TA; Burchardi H
    Anaesthesist; 1994 Feb; 43(2):115-20. PubMed ID: 8141437
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Positive end-expiratory pressure titration at bedside using electrical impedance tomography in post-operative cardiac surgery patients.
    Karsten J; Grusnick C; Paarmann H; Heringlake M; Heinze H
    Acta Anaesthesiol Scand; 2015 Jul; 59(6):723-32. PubMed ID: 25867049
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single centre experience.
    Heines SJH; Strauch U; van de Poll MCG; Roekaerts PMHJ; Bergmans DCJJ
    J Clin Monit Comput; 2019 Apr; 33(2):291-300. PubMed ID: 29845479
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Longitudinal PEEP Responses Differ Between Children With ARDS and at Risk for ARDS.
    Ilia S; Geromarkaki E; Briassoulis P; Bourmpaki P; Tavladaki T; Miliaraki M; Briassoulis G
    Respir Care; 2021 Mar; 66(3):391-402. PubMed ID: 33024001
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Measurement of Electrical Impedance Tomography-Based Regional Ventilation Delay for Individualized Titration of End-Expiratory Pressure.
    Muders T; Hentze B; Kreyer S; Wodack KH; Leonhardt S; Hedenstierna G; Wrigge H; Putensen C
    J Clin Med; 2021 Jun; 10(13):. PubMed ID: 34208890
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A clinical study on mechanical ventilation PEEP setting for traumatic ARDS patients guided by esophageal pressure.
    Wang B; Wu B; Ran YN
    Technol Health Care; 2019; 27(1):37-47. PubMed ID: 30475777
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Best compliance during a decremental, but not incremental, positive end-expiratory pressure trial is related to open-lung positive end-expiratory pressure: a mathematical model of acute respiratory distress syndrome lungs.
    Hickling KG
    Am J Respir Crit Care Med; 2001 Jan; 163(1):69-78. PubMed ID: 11208628
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography - a randomized controlled trial.
    Weber J; Gutjahr J; Schmidt J; Lozano-Zahonero S; Borgmann S; Schumann S; Wirth S
    BMC Anesthesiol; 2020 Feb; 20(1):42. PubMed ID: 32079526
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimizing PEEP by Electrical Impedance Tomography in a Porcine Animal Model of ARDS.
    Hochhausen N; Biener I; Rossaint R; Follmann A; Bleilevens C; Braunschweig T; Leonhardt S; Czaplik M
    Respir Care; 2017 Mar; 62(3):340-349. PubMed ID: 27999152
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Assessment of Lung Recruitment by Electrical Impedance Tomography and Oxygenation in ARDS Patients.
    Yun L; He HW; Möller K; Frerichs I; Liu D; Zhao Z
    Medicine (Baltimore); 2016 May; 95(22):e3820. PubMed ID: 27258527
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Positive end-expiratory pressure and tidal volume titration after recruitment maneuver in a canine model of acute respiratory distress syndrome].
    Zhan QY; Wang C; Sun B; Pang BS
    Zhonghua Jie He He Hu Xi Za Zhi; 2005 Nov; 28(11):763-8. PubMed ID: 16324272
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.