These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 34807141)

  • 1. Sub-pixel position estimation algorithm based on Gaussian fitting and sampling theorem interpolation for wafer alignment.
    Pan S; Wang S; Xu J; Fan L; Yuan F; Shu T; Dai F; Yan X; Bu Y; Wang X
    Appl Opt; 2021 Nov; 60(31):9607-9618. PubMed ID: 34807141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aberration evaluation of alignment optics in lithographic tools by use of a step-height structure highly sensitive to the asymmetry of an optical image.
    Ina H; Takeda M
    Appl Opt; 2007 Jun; 46(17):3485-92. PubMed ID: 17514307
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gaussian fitting algorithm with multi-geometric parameters for rotated elliptical beam profiling using pixel ion chamber.
    Lei H; Tan P; Hu D; Yu Y; Lin Y; Zhang Z; Li J
    Med Phys; 2021 Sep; 48(9):4799-4811. PubMed ID: 34314534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement algorithm for wafer alignment based on principal component analysis.
    Shu T; Wang S; Xu J; Fan L; Yuan F; Pan S; Dai F; Bu Y; Wang X
    Appl Opt; 2021 Jul; 60(19):5569-5580. PubMed ID: 34263847
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Phase Amplified Correlation for Improved Sub-pixel Motion Estimation.
    Konstantinidis D; Stathaki T; Argyriou V
    IEEE Trans Image Process; 2019 Jan; ():. PubMed ID: 30676956
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single-molecule localization microscopy based on denoising, interpolation and local maxima.
    Cheng T
    Microscopy (Oxf); 2023 Aug; 72(4):336-342. PubMed ID: 36412750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Alignment mark optimization for improving signal-to-noise ratio of wafer alignment signal.
    Du J; Dai F; Wang X
    Appl Opt; 2019 Jan; 58(1):9-14. PubMed ID: 30645505
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image interpolation and denoising for division of focal plane sensors using Gaussian processes.
    Gilboa E; Cunningham JP; Nehorai A; Gruev V
    Opt Express; 2014 Jun; 22(12):15277-91. PubMed ID: 24977618
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A MAP-based image interpolation method via Viterbi decoding of Markov chains of interpolation functions.
    Vedadi F; Shirani S
    IEEE Trans Image Process; 2014 Jan; 23(1):424-38. PubMed ID: 24239997
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Comparative Study of Structural Deformation Test Based on Edge Detection and Digital Image Correlation.
    Tang R; Chen W; Wu Y; Xiong H; Yan B
    Sensors (Basel); 2023 Apr; 23(8):. PubMed ID: 37112175
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Star Centroiding Based on Fast Gaussian Fitting for Star Sensors.
    Wan X; Wang G; Wei X; Li J; Zhang G
    Sensors (Basel); 2018 Aug; 18(9):. PubMed ID: 30154307
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration method of overlay measurement error caused by asymmetric mark.
    Du J; Dai F; Bu Y; Wang X
    Appl Opt; 2018 Nov; 57(33):9814-9821. PubMed ID: 30462016
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Moiré-Based Alignment Using Centrosymmetric Grating Marks for High-Precision Wafer Bonding.
    Huang B; Wang C; Fang H; Zhou S; Suga T
    Micromachines (Basel); 2019 May; 10(5):. PubMed ID: 31121955
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Alignment for imprint lithography using nDSE and shallow molds.
    Picciotto C; Gao J; Yu Z; Wu W
    Nanotechnology; 2009 Jun; 20(25):255304. PubMed ID: 19487804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. WE-C-217BCD-05: A Novel Interpolation Method for the 3D Reconstruction of Cell Structures.
    Sa Y; Zhang Y; Li R; Huang Y; Zhang Y; Hu X; Feng Y
    Med Phys; 2012 Jun; 39(6Part27):3950. PubMed ID: 28519972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Research on fast implementation method of image Gaussian RBF interpolation based on CUDA].
    Chen H; Yu H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2014 Apr; 31(2):237-44. PubMed ID: 25039120
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An Improved Algorithm for Reprojecting Rays through Pixel Images.
    Joseph PM
    IEEE Trans Med Imaging; 1982; 1(3):192-6. PubMed ID: 18238275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time interpolation for true 3-dimensional ultrasound image volumes.
    Ji S; Roberts DW; Hartov A; Paulsen KD
    J Ultrasound Med; 2011 Feb; 30(2):243-52. PubMed ID: 21266563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Study on application of Gaussian fitting algorithm to building model of spectral analysis].
    Li M; Sheng Y
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Oct; 28(10):2352-5. PubMed ID: 19123405
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI.
    Rea M; McRobbie D; Elhawary H; Tse ZT; Lamperth M; Young I
    MAGMA; 2009 Apr; 22(2):71-6. PubMed ID: 18802730
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.