These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 34813020)
1. Concurrently bendable and rotatable continuum tubular robot for omnidirectional multi-core transurethral prostate biopsy. Xiao X; Wu Y; Wu Q; Ren H Med Biol Eng Comput; 2022 Jan; 60(1):229-238. PubMed ID: 34813020 [TBL] [Abstract][Full Text] [Related]
2. Toward autonomous robotic prostate biopsy: a pilot study. Maris B; Tenga C; Vicario R; Palladino L; Murr N; De Piccoli M; Calanca A; Puliatti S; Micali S; Tafuri A; Fiorini P Int J Comput Assist Radiol Surg; 2021 Aug; 16(8):1393-1401. PubMed ID: 34224068 [TBL] [Abstract][Full Text] [Related]
3. Accuracy study of a robotic system for MRI-guided prostate needle placement. Seifabadi R; Cho NB; Song SE; Tokuda J; Hata N; Tempany CM; Fichtinger G; Iordachita I Int J Med Robot; 2013 Sep; 9(3):305-16. PubMed ID: 22678990 [TBL] [Abstract][Full Text] [Related]
4. In vivo evaluation of angulated needle-guide template for MRI-guided transperineal prostate biopsy. Moreira P; Grimble J; Iftimia N; Bay CP; Tuncali K; Park J; Tokuda J Med Phys; 2021 May; 48(5):2553-2565. PubMed ID: 33651407 [TBL] [Abstract][Full Text] [Related]
5. A magnetic resonance image-guided breast needle intervention robot system: overview and design considerations. Park SB; Kim JG; Lim KW; Yoon CH; Kim DJ; Kang HS; Jo YH Int J Comput Assist Radiol Surg; 2017 Aug; 12(8):1319-1331. PubMed ID: 28168682 [TBL] [Abstract][Full Text] [Related]
6. Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom study. Seifabadi R; Song SE; Krieger A; Cho NB; Tokuda J; Fichtinger G; Iordachita I Int J Comput Assist Radiol Surg; 2012 Mar; 7(2):181-90. PubMed ID: 21698389 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of robot-assisted MRI-guided prostate biopsy: needle path analysis during clinical trials. Moreira P; Patel N; Wartenberg M; Li G; Tuncali K; Heffter T; Burdette EC; Iordachita I; Fischer GS; Hata N; Tempany CM; Tokuda J Phys Med Biol; 2018 Oct; 63(20):20NT02. PubMed ID: 30226214 [TBL] [Abstract][Full Text] [Related]
8. Development of a transperineal prostate biopsy robot guided by MRI-TRUS image. Wang W; Pan B; Fu Y; Liu Y Int J Med Robot; 2021 Aug; 17(4):e2266. PubMed ID: 33887097 [TBL] [Abstract][Full Text] [Related]
9. Deflection Analysis of Different Needle Designs for Prostate Biopsy and Focal Therapy. Stone NN; Mouraviev V; Schechter D; Goetz J; Lucia MS; Smith EE; Crawford ED Technol Cancer Res Treat; 2017 Oct; 16(5):654-661. PubMed ID: 27708117 [TBL] [Abstract][Full Text] [Related]
10. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates. Tilak G; Tuncali K; Song SE; Tokuda J; Olubiyi O; Fennessy F; Fedorov A; Penzkofer T; Tempany C; Hata N J Magn Reson Imaging; 2015 Jul; 42(1):63-71. PubMed ID: 25263213 [TBL] [Abstract][Full Text] [Related]
12. Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals. Komaki T; Hiraki T; Kamegawa T; Matsuno T; Sakurai J; Matsuura R; Yamaguchi T; Sasaki T; Mitsuhashi T; Okamoto S; Uka M; Matsui Y; Iguchi T; Gobara H; Kanazawa S Eur Radiol; 2020 Mar; 30(3):1342-1349. PubMed ID: 31773299 [TBL] [Abstract][Full Text] [Related]
13. A workspace-orientated needle-guiding robot for 3T MRI-guided transperineal prostate intervention: evaluation of in-bore workspace and MRI compatibility. Song SE; Hata N; Iordachita I; Fichtinger G; Tempany C; Tokuda J Int J Med Robot; 2013 Mar; 9(1):67-74. PubMed ID: 22492680 [TBL] [Abstract][Full Text] [Related]
14. Development of a novel robot for transperineal needle based interventions: focal therapy, brachytherapy and prostate biopsies. Long JA; Hungr N; Baumann M; Descotes JL; Bolla M; Giraud JY; Rambeaud JJ; Troccaz J J Urol; 2012 Oct; 188(4):1369-74. PubMed ID: 22906671 [TBL] [Abstract][Full Text] [Related]
16. System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance. Fichtinger G; DeWeese TL; Patriciu A; Tanacs A; Mazilu D; Anderson JH; Masamune K; Taylor RH; Stoianovici D Acad Radiol; 2002 Jan; 9(1):60-74. PubMed ID: 11918360 [TBL] [Abstract][Full Text] [Related]
17. [Accuracy analysis of robotic assistant needle placement for lateral skull base biopsy]. Zhu JH; Wang J; Liu XJ; Guo CB Zhonghua Kou Qiang Yi Xue Za Zhi; 2018 Aug; 53(8):519-523. PubMed ID: 30078263 [No Abstract] [Full Text] [Related]
18. [Robot-controlled MRI-guided transrectal prostate biopsy, a promising technique]. Raat HPJ; van Stiphout RSA; van Gorp ACF; Barentsz J Ned Tijdschr Geneeskd; 2020 Aug; 164():. PubMed ID: 32940977 [TBL] [Abstract][Full Text] [Related]
19. Towards synergistic control of hands-on needle insertion with automated needle steering for MRI-guided prostate interventions. Wartenberg M; Patel N; Gang Li ; Fischer GS Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5116-5119. PubMed ID: 28269418 [TBL] [Abstract][Full Text] [Related]
20. First report of robot-assisted transperineal fusion versus off-target biopsy in patients undergoing repeat prostate biopsy. Kaufmann S; Mischinger J; Amend B; Rausch S; Adam M; Scharpf M; Fend F; Kramer U; Notohamiprodjo M; Nikolaou K; Stenzl A; Bedke J; Kruck S World J Urol; 2017 Jul; 35(7):1023-1029. PubMed ID: 27847972 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]