183 related articles for article (PubMed ID: 34818621)
1. Feasibility of 18-MV grid therapy from radiation protection aspects: unwanted dose and fatal cancer risk caused by photoneutrons and scattered photons.
Karimi AH; Mirian SF; Mahmoudi F; Geraily G; Vega-Carrillo HR; Mohiuddin M
Comput Methods Programs Biomed; 2022 Jan; 213():106524. PubMed ID: 34818621
[TBL] [Abstract][Full Text] [Related]
2. How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
Mahmoudi F; Mohammadi N; Haghighi M; Alirezaei Z; Jabbari I; Chegeni N; Elmtalab S; Vega-Carrillo HR; Kazemian A; Geraily G; Karimi AH
PLoS One; 2023; 18(1):e0280433. PubMed ID: 36638131
[TBL] [Abstract][Full Text] [Related]
3. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
Chibani O; Ma CM
Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
[TBL] [Abstract][Full Text] [Related]
4. Photoneutron Dose Estimation in GRID Therapy Using an Anthropomorphic Phantom: A Monte Carlo Study.
Chegeni N; Karimi AH; Jabbari I; Arvandi S
J Med Signals Sens; 2018; 8(3):175-183. PubMed ID: 30181966
[TBL] [Abstract][Full Text] [Related]
5. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
[TBL] [Abstract][Full Text] [Related]
6. Grid therapy vs. conventional radiotherapy - 18 MV treatments: Photoneutron contamination along the maze of a linac bunker.
Karimi AH; Vega-Carrillo HR
Appl Radiat Isot; 2020 Apr; 158():109064. PubMed ID: 32174378
[TBL] [Abstract][Full Text] [Related]
7. Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study.
Martínez-Rovira I; Puxeu-Vaqué J; Prezado Y
Med Phys; 2017 Oct; 44(10):5378-5383. PubMed ID: 28736809
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of neutron dose equivalent by photoneutron production inside the primary barriers of a radiotherapy vault.
Choi CH; Park SY; Park JM; Chun M; Kim JI
Phys Med; 2018 Apr; 48():1-5. PubMed ID: 29728220
[TBL] [Abstract][Full Text] [Related]
9. Effect of wedge filter and field size on photoneutron dose equivalent for an 18MV photon beam of a medical linear accelerator.
Mesbahi A; Keshtkar A; Mohammadi E; Mohammadzadeh M
Appl Radiat Isot; 2010 Jan; 68(1):84-9. PubMed ID: 19748787
[TBL] [Abstract][Full Text] [Related]
10. Doses to patients from photoneutrons emitted in a medical linear accelerator.
Saeed MK; Moustafa O; Yasin OA; Tuniz C; Habbani FI
Radiat Prot Dosimetry; 2009 Feb; 133(3):130-5. PubMed ID: 19287045
[TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo study on neutron and electron contamination of an unflattened 18-MV photon beam.
Mesbahi A
Appl Radiat Isot; 2009 Jan; 67(1):55-60. PubMed ID: 18760613
[TBL] [Abstract][Full Text] [Related]
12. On the neutron radiation field and air activation around a medical electron linac.
Horst F; Fehrenbacher G; Zink K
Radiat Prot Dosimetry; 2017 Apr; 174(2):147-158. PubMed ID: 27170731
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study.
Prasada DNY; Ciamaudi N; Fadli M; Tursinah R; Pawiro SA
Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34619664
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo estimation of photoneutrons contamination from high-energy X-ray medical accelerators in treatment room and maze: a simplified model.
Zabihzadeh M; Ay MR; Allahverdi M; Mesbahi A; Mahdavi SR; Shahriari M
Radiat Prot Dosimetry; 2009 Jul; 135(1):21-32. PubMed ID: 19483207
[TBL] [Abstract][Full Text] [Related]
15. High-dose spatially fractionated GRID radiation therapy (SFGRT): a comparison of treatment outcomes with Cerrobend vs. MLC SFGRT.
Neuner G; Mohiuddin MM; Vander Walde N; Goloubeva O; Ha J; Yu CX; Regine WF
Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1642-9. PubMed ID: 21531514
[TBL] [Abstract][Full Text] [Related]
16. Study of Photoneutron Production for the 18 MV Photon Beam of the Siemens Medical linac by Monte Carlo Simulation.
H D; A A M; M G; S M; C K
J Biomed Phys Eng; 2020 Dec; 10(6):679-690. PubMed ID: 33364205
[TBL] [Abstract][Full Text] [Related]
17. Beam quality and the mystery behind the lower percentage depth dose in grid radiation therapy.
Karimi AH; Das IJ; Chegeni N; Jabbari I; Jafari F; Geraily G
Sci Rep; 2024 Feb; 14(1):4510. PubMed ID: 38402259
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of Photoneutron Dose Measured by Bubble Detectors in Conventional Linacs and Cyberknife Unit: Effective Dose and Secondary Malignancy Risk Estimation.
Biltekin F; Yeginer M; Ozyigit G
Technol Cancer Res Treat; 2016 Aug; 15(4):560-5. PubMed ID: 26152750
[TBL] [Abstract][Full Text] [Related]
19. The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study.
Talebi AS; Maleki M; Hejazi P; Jadidi M; Ghorbani R
J Biomed Phys Eng; 2018 Sep; 8(3):231-240. PubMed ID: 30320027
[TBL] [Abstract][Full Text] [Related]
20. The impact of automatic wedge filter on photoneutron and photon spectra of an 18-MV photon beam.
Ghavami SM; Mesbahi A; Mohammadi E
Radiat Prot Dosimetry; 2010 Feb; 138(2):123-8. PubMed ID: 19789200
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]