These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 34824843)

  • 1. Synchronous early-stage breast cancer and axillary follicular lymphoma diagnosed by core needle biopsy: A case report.
    Eto R; Nakamura R; Yamamoto N; Miyaki T; Hayama S; Sonoda I; Itami M; Tsujimura H; Hashimoto H; Otsuka M
    Mol Clin Oncol; 2022 Jan; 16(1):3. PubMed ID: 34824843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of sentinel lymph node biopsy by ultrasound-guided core needle biopsy for patients with suspicious node positive breast cancer.
    Nakamura R; Yamamoto N; Miyaki T; Itami M; Shina N; Ohtsuka M
    Breast Cancer; 2018 Jan; 25(1):86-93. PubMed ID: 28735457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of sentinel lymph node biopsy in newly diagnosed invasive breast cancer patients with suspicious node: a comparative accuracy survey of fine-needle aspiration biopsy versus core-needle biopsy.
    Bhandari A; Xia E; Wang Y; Sindan N; Kc R; Guan Y; Lin YL; Wang X; Zhang X; Wang O
    Am J Transl Res; 2018; 10(6):1860-1873. PubMed ID: 30018726
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axillary lymph node biopsy in newly diagnosed invasive breast cancer: comparative accuracy of fine-needle aspiration biopsy versus core-needle biopsy.
    Rautiainen S; Masarwah A; Sudah M; Sutela A; Pelkonen O; Joukainen S; Sironen R; Kärjä V; Vanninen R
    Radiology; 2013 Oct; 269(1):54-60. PubMed ID: 23771915
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improving the Accuracy of Axillary Lymph Node Surgery in Breast Cancer with Ultrasound-Guided Wire Localization of Biopsy Proven Metastatic Lymph Nodes.
    Plecha D; Bai S; Patterson H; Thompson C; Shenk R
    Ann Surg Oncol; 2015 Dec; 22(13):4241-6. PubMed ID: 25814365
    [TBL] [Abstract][Full Text] [Related]  

  • 6. US-guided 14G core needle biopsy: comparison between underestimated and correctly diagnosed breast cancers.
    Kim H; Youk JH; Kim JA; Gweon HM; Jung WH; Son EJ
    Asian Pac J Cancer Prev; 2014; 15(7):3179-83. PubMed ID: 24815467
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axillary lymph nodes suspicious for breast cancer metastasis: sampling with US-guided 14-gauge core-needle biopsy--clinical experience in 100 patients.
    Abe H; Schmidt RA; Kulkarni K; Sennett CA; Mueller JS; Newstead GM
    Radiology; 2009 Jan; 250(1):41-9. PubMed ID: 18955508
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Follicular lymphoma without lymphadenopathy incidentally diagnosed by sentinel lymph node biopsy during breast cancer surgery: a case report.
    Hiraoka E; Masumoto N; Furukawa T; Kuraoka N; Nagamine I; Kido A; Sentani K; Ootagaki S
    Surg Case Rep; 2022 Sep; 8(1):167. PubMed ID: 36098873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can Breast Cancer Biopsy Influence Sentinel Lymph Node Status?
    Giuliani M; Patrolecco F; Rella R; Di Giovanni SE; Infante A; Rinaldi P; Romani M; Mulè A; Arciuolo D; Belli P; Bonomo L
    Clin Breast Cancer; 2016 Dec; 16(6):e153-e157. PubMed ID: 27400807
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Synchronous bilateral non-Hodgkin's diffuse large B-cell lymphoma of the breast and left breast invasive ductal carcinoma: a case report and review of literature.
    Liu W; Zhu H; Zhou X
    Int J Clin Exp Pathol; 2014; 7(10):7042-8. PubMed ID: 25400793
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Meta-analysis of the diagnostic accuracy of ultrasound-guided fine-needle aspiration and core needle biopsy in diagnosing axillary lymph node metastasis.
    Balasubramanian I; Fleming CA; Corrigan MA; Redmond HP; Kerin MJ; Lowery AJ
    Br J Surg; 2018 Sep; 105(10):1244-1253. PubMed ID: 29972239
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Axillary evaluation is not warranted in patients preoperatively diagnosed with ductal carcinoma in situ by core needle biopsy.
    Si J; Guo R; Huang N; Xiu B; Zhang Q; Chi W; Wu J
    Cancer Med; 2019 Dec; 8(18):7586-7593. PubMed ID: 31660702
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical Usefulness of Ultrasound-Guided Fine Needle Aspiration and Core Needle Biopsy for Patients with Axillary Lymphadenopathy.
    Fujioka T; Mori M; Kubota K; Yamaga E; Yashima Y; Oda G; Nakagawa T; Onishi I; Ishiba T; Tateishi U
    Medicina (Kaunas); 2021 Jul; 57(7):. PubMed ID: 34357003
    [No Abstract]   [Full Text] [Related]  

  • 14. Breast cancer prognosis and isolated tumor cell findings in axillary lymph nodes after core needle biopsy and fine needle aspiration cytology: Biopsy method and breast cancer outcome.
    Liikanen J; Leidenius M; Joensuu H; Vironen J; Heikkilä P; Meretoja T
    Eur J Surg Oncol; 2016 Jan; 42(1):64-70. PubMed ID: 26427542
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Contralateral breast cancer adjacent to a fibroadenoma: report of a case.
    Iwamoto M; Takei H; Iida S; Yamashita K; Yanagihara K; Kurita T; Tsuchiya S; Kanazawa Y; Uchida E
    J Nippon Med Sch; 2014; 81(3):168-72. PubMed ID: 24998964
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of ultrasound-guided core needle biopsy in cervical lymphadenopathy: A retrospective study of 6,695 cases.
    Han F; Xu M; Xie T; Wang JW; Lin QG; Guo ZX; Zheng W; Han J; Lin X; Zou RH; Zhou JH; Li AH
    Eur Radiol; 2018 May; 28(5):1809-1817. PubMed ID: 29188372
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of axillary involvement by ultrasound-guided lymph node biopsy: A prospective study.
    Jankowski C; Hudry D; Vaillant D; Varbedian O; Mejean N; Guy F; Feutray S; Coutant C
    Gynecol Obstet Fertil; 2015 Jun; 43(6):431-6. PubMed ID: 25986396
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [High frequency ultrasound combined with ultrasound-guided core needle biopsy for the diagnosis of primary thyroid lymphoma].
    Xu LL; Li SY; Zhu J; Lyu JG; Zhang MX; Gao L; Xie L; Jiang ZN; Fu GX
    Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2021 Aug; 56(8):858-862. PubMed ID: 34521172
    [No Abstract]   [Full Text] [Related]  

  • 19. Image-guided core needle biopsy in the diagnosis of malignant lymphoma.
    Skelton E; Jewison A; Okpaluba C; Sallomi J; Lowe J; Ramesar K; Grace R; Howlett DC
    Eur J Surg Oncol; 2015 Jul; 41(7):852-8. PubMed ID: 25980745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of ultrasound-guided core needle gun biopsy in diagnosing cervical lymphadenopathy.
    Oh KH; Woo JS; Cho JG; Baek SK; Jung KY; Kwon SY
    Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Dec; 133(6):401-404. PubMed ID: 27592165
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.