BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 34830814)

  • 1. Accuracy and Safety of Ultrasound-Guided Core Needle Biopsy of Soft Tissue Tumors in an Outpatient Setting: A Sarcoma Center Analysis of 392 Consecutive Patients.
    Weigl H; Hohenberger P; Marx A; Vassos N; Jakob J; Galata C
    Cancers (Basel); 2021 Nov; 13(22):. PubMed ID: 34830814
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnostic accuracy of ultrasound-guided core needle biopsy versus incisional biopsy in soft tissue sarcoma: an institutional experience.
    Cernakova M; Hobusch GM; Amann G; Funovics PT; Windhager R; Panotopoulos J
    Sci Rep; 2021 Sep; 11(1):17832. PubMed ID: 34497298
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Diagnostic value of ultrasound-guided core needle biopsy for soft tissue tumors].
    Na J; Fang ZW; Zhao AL; Li JY
    Zhonghua Bing Li Xue Za Zhi; 2013 Mar; 42(3):158-62. PubMed ID: 23769433
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic concordance between ultrasound-guided core needle biopsy and surgical resection specimens for histological grading of extremity and trunk soft tissue sarcoma.
    Tan A; Rajakulasingam R; Saifuddin A
    Skeletal Radiol; 2021 Jan; 50(1):43-50. PubMed ID: 32514582
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computed tomography-guided core needle biopsy for bone and soft tissue tumors.
    Issakov J; Flusser G; Kollender Y; Merimsky O; Lifschitz-Mercer B; Meller I
    Isr Med Assoc J; 2003 Jan; 5(1):28-30. PubMed ID: 12592954
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the diagnostic performances of core needle biopsy in myxoid versus non-myxoid tumors.
    Rohela H; Lee C; Yoo HJ; Kim HS; Kim Y; Cho HS; Han I
    Eur J Surg Oncol; 2019 Jul; 45(7):1293-1298. PubMed ID: 31085026
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of a self-contained vacuum-assisted biopsy system in the assessment of soft tissue tumors.
    Simidjiiska-Belyaeva M; Belyaev O; Lehnhardt M; Harati K; Stricker I; Nicolas V; Daigeler A
    J Surg Oncol; 2019 Sep; 120(4):740-745. PubMed ID: 31309561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic accuracy and safety of percutaneous core needle biopsy of retroperitoneal tumours.
    Nardi W; Nicolas N; El Zein S; Tzanis D; Bouhadiba T; Helfre S; Watson S; Brisse HJ; Servois V; Bonvalot S
    Eur J Surg Oncol; 2024 Jan; 50(1):107298. PubMed ID: 38086314
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous core needle biopsy versus open biopsy in diagnostics of bone and soft tissue sarcoma: a retrospective study.
    Pohlig F; Kirchhoff C; Lenze U; Schauwecker J; Burgkart R; Rechl H; von Eisenhart-Rothe R
    Eur J Med Res; 2012 Nov; 17(1):29. PubMed ID: 23114293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Utility and Safety of Repeated Ultrasound-Guided Core Needle Biopsy of Focal Liver Masses.
    Kim JS; Won HJ; Lee SJ; Kim SY; Shin YM; Kim PN
    J Ultrasound Med; 2018 Feb; 37(2):447-452. PubMed ID: 28850692
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Core needle biopsy versus incisional biopsy for differentiation of soft-tissue sarcomas: A systematic review and meta-analysis.
    Birgin E; Yang C; Hetjens S; Reissfelder C; Hohenberger P; Rahbari NN
    Cancer; 2020 Jan; 126(9):1917-1928. PubMed ID: 32022262
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic ultrasound guided fine-needle aspiration vs core needle biopsy for solid pancreatic lesions: Comparison of diagnostic accuracy and procedural efficiency.
    Syed A; Babich O; Rao B; Singh S; Carleton N; Gulati A; Kulkarni A; Garg M; Farah K; Kochhar G; Morrissey S; Mitre M; Kulkarni A; Dhawan M; Silverman JF; Pharaon M; Thakkar S
    Diagn Cytopathol; 2019 Nov; 47(11):1138-1144. PubMed ID: 31313531
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Open Incisional Biopsy and Ultrasound-Guided Core Needle Biopsy of Extremity-Localized Musculoskeletal Tumors].
    Pazourek L; StaniczkovÁ Zambo I; TomÁŠ T; Mahdal M
    Acta Chir Orthop Traumatol Cech; 2020; 87(6):421-428. PubMed ID: 33408008
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Association of core needle biopsy tract resection with local recurrence in extremity soft tissue sarcoma.
    Siddiqi MA; Kim HS; Jede F; Han I
    Skeletal Radiol; 2017 Apr; 46(4):507-512. PubMed ID: 28175961
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk Factors for Diagnostic Failure of Ultrasound-Guided Core Needle Biopsy of Soft-Tissue Tumors Based on World Health Organization Classification Category and Biologic Potential.
    Yoon MA; Chung HW; Chee CG; Lee MH; Lee SH; Shin MJ
    AJR Am J Roentgenol; 2020 Feb; 214(2):413-421. PubMed ID: 31670587
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules.
    Chen BT; Jain AB; Dagis A; Chu P; Vora L; Maghami E; Salehian B
    Endocr Pract; 2015 Feb; 21(2):128-35. PubMed ID: 25297665
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image-Guided Core Needle Biopsy of Adipocytic Tumors: Diagnostic Accuracy and Concordance With Final Surgical Pathology.
    Thavikulwat AC; Wu JS; Chen X; Anderson ME; Ward A; Kung J
    AJR Am J Roentgenol; 2021 Apr; 216(4):997-1002. PubMed ID: 33624523
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of the Diagnostic Efficacy of Ultrasound-Guided Core Needle Biopsy With 18- Versus 20-Gauge Needles for Thyroid Nodules.
    Ahn HS; Seo M; Ha SM; Kim HS
    J Ultrasound Med; 2018 Nov; 37(11):2565-2574. PubMed ID: 29575135
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High diagnostic accuracy of core needle biopsy of soft tissue tumors: An institutional experience.
    Colletti SM; Tranesh GA; Whetsell CR; Chambers LN; Nassar A
    Diagn Cytopathol; 2016 Apr; 44(4):291-8. PubMed ID: 26799242
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of needle biopsy of breast lesions visible on ultrasound: audit of fine needle versus core needle biopsy in 3233 consecutive samplings with ascertained outcomes.
    Brancato B; Crocetti E; Bianchi S; Catarzi S; Risso GG; Bulgaresi P; Piscioli F; Scialpi M; Ciatto S; Houssami N
    Breast; 2012 Aug; 21(4):449-54. PubMed ID: 22088803
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.