BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 34832321)

  • 1. Novel Design and Finite Element Analysis of Diamond-like Porous Implants with Low Stiffness.
    Zhang J; Zhang X; Chen Y; Feng W; Chen X
    Materials (Basel); 2021 Nov; 14(22):. PubMed ID: 34832321
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Analysis of Axial Gradient Porous Dental Implants: A Finite Element Analysis.
    Zhang C; Wang Y
    J Funct Biomater; 2023 Nov; 14(12):. PubMed ID: 38132811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants: a 3-dimensional finite element analysis.
    Xiao JR; Li YF; Guan SM; Song L; Xu LX; Kong L
    J Oral Maxillofac Surg; 2011 Jul; 69(7):e273-81. PubMed ID: 21367505
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Three-dimensional finite element analysis of the stress distribution of bone tissue around porous titanium implant].
    Liu TS; Gao R; Wei T; Sun HQ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):35-40. PubMed ID: 30630257
    [No Abstract]   [Full Text] [Related]  

  • 5. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants.
    Cheong VS; Fromme P; Mumith A; Coathup MJ; Blunn GW
    J Mech Behav Biomed Mater; 2018 Nov; 87():230-239. PubMed ID: 30086415
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.
    Rasouli-Ghahroudi AA; Geramy A; Yaghobee S; Khorsand A; Yousefifakhr H; Rokn A; Soolari A
    J Int Acad Periodontol; 2015 Jan; 17(1):2-13. PubMed ID: 26233968
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 3-D Finite Element Analysis of Stress Distribution on Implant-supported Fixed Prosthesis with Four Different Commercially Available Implant Systems.
    Tyagi R; Kumar S; Aggarwal R; Choudhary S; Malethia A; Saini N
    J Contemp Dent Pract; 2020 Aug; 21(8):835-840. PubMed ID: 33568601
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional finite element analysis.
    Masoomi F; Mahboub F
    Eur J Transl Myol; 2024 Feb; 34(1):. PubMed ID: 38363221
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Different short dental implants on the stress distribution in posterior maxilla: a three-dimensional finite element analysis].
    Li X; Staden RV; Hong G
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2014 Nov; 49(11):662-6. PubMed ID: 25622500
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of Porous Microstructures on the Biomechanical Characteristics of a Root Analogue Implant: An Animal Study and a Finite Element Analysis.
    Liu T; Chen Y; Apicella A; Mu Z; Yu T; Huang Y; Wang C
    ACS Biomater Sci Eng; 2020 Nov; 6(11):6356-6367. PubMed ID: 33449664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.
    Cheong VS; Fromme P; Coathup MJ; Mumith A; Blunn GW
    Ann Biomed Eng; 2020 Jan; 48(1):502-514. PubMed ID: 31549330
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
    Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
    J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical Comparison of a New Triple Cylindrical Implant Design and a Conventional Cylindrical Implant Design on the Mandible by Three-Dimensional Finite Element Analysis.
    Bayrak A; Yaramanoğlu P; Kılıçarslan MA; Yaramanoğlu B; Akat B
    Int J Oral Maxillofac Implants; 2020; 35(2):257-264. PubMed ID: 32142561
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture.
    Shigemitsu R; Yoda N; Ogawa T; Kawata T; Gunji Y; Yamakawa Y; Ikeda K; Sasaki K
    Comput Biol Med; 2014 Nov; 54():44-52. PubMed ID: 25212117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of stress/strain in dental implants and abutments of alternative materials compared to conventional titanium alloy-3D non-linear finite element analysis.
    Tretto PHW; Dos Santos MBF; Spazzin AO; Pereira GKR; Bacchi A
    Comput Methods Biomech Biomed Engin; 2020 Jun; 23(8):372-383. PubMed ID: 32116034
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
    Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
    Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
    Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
    J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stress Distribution on Short Implants at Maxillary Posterior Alveolar Bone Model With Different Bone-to-Implant Contact Ratio: Finite Element Analysis.
    Yazicioglu D; Bayram B; Oguz Y; Cinar D; Uckan S
    J Oral Implantol; 2016 Feb; 42(1):26-33. PubMed ID: 26867093
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone.
    Zheng L; Yang J; Hu X; Luo J
    Acta Bioeng Biomech; 2014; 16(3):21-8. PubMed ID: 25307871
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
    Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
    J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.