BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 34837177)

  • 1. Azimuthal Beam Scanning Microscope Design and Implementation for Axial Localization with Scanning Angle Interference Microscopy.
    Colville M; Park S; Singh A; Paszek M; Zipfel WR
    Methods Mol Biol; 2022; 2393():127-152. PubMed ID: 34837177
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-speed device synchronization in optical microscopy with an open-source hardware control platform.
    Colville MJ; Park S; Zipfel WR; Paszek MJ
    Sci Rep; 2019 Aug; 9(1):12188. PubMed ID: 31434941
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effective elimination of laser interference fringing in fluorescence microscopy by spinning azimuthal incidence angle.
    Mattheyses AL; Shaw K; Axelrod D
    Microsc Res Tech; 2006 Aug; 69(8):642-7. PubMed ID: 16770769
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Eliminating unwanted far-field excitation in objective-type TIRF. Part I. identifying sources of nonevanescent excitation light.
    Brunstein M; Teremetz M; Hérault K; Tourain C; Oheim M
    Biophys J; 2014 Mar; 106(5):1020-32. PubMed ID: 24606927
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Eliminating unwanted far-field excitation in objective-type TIRF. Part II. combined evanescent-wave excitation and supercritical-angle fluorescence detection improves optical sectioning.
    Brunstein M; Hérault K; Oheim M
    Biophys J; 2014 Mar; 106(5):1044-56. PubMed ID: 24606929
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nanoscale cellular imaging with scanning angle interference microscopy.
    DuFort C; Paszek M
    Methods Cell Biol; 2014; 123():235-52. PubMed ID: 24974031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Artifact-free objective-type multicolor total internal reflection fluorescence microscopy with light-emitting diode light sources-Part I.
    Kogel A; Kalwa H; Urban N; Schaefer M
    J Biophotonics; 2019 Nov; 12(11):e201900033. PubMed ID: 31148410
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Autocalibrated scanning-angle prism-type total internal reflection fluorescence microscopy for nanometer-precision axial position determination.
    Sun W; Marchuk K; Wang G; Fang N
    Anal Chem; 2010 Mar; 82(6):2441-7. PubMed ID: 20184351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Axicon-based Bessel beams for flat-field illumination in total internal reflection fluorescence microscopy.
    Schreiber B; Elsayad K; Heinze KG
    Opt Lett; 2017 Oct; 42(19):3880-3883. PubMed ID: 28957150
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Total internal reflection fluorescence (TIRF) microscopy.
    Fish KN
    Curr Protoc Cytom; 2009 Oct; Chapter 12():Unit12.18. PubMed ID: 19816922
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy.
    Olveczky BP; Periasamy N; Verkman AS
    Biophys J; 1997 Nov; 73(5):2836-47. PubMed ID: 9370477
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Whole-cell scan using automatic variable-angle and variable-illumination-depth pseudo-total internal reflection fluorescence microscopy.
    Sun W; Xu A; Marchuk K; Wang G; Fang N
    J Lab Autom; 2011 Aug; 16(4):255-62. PubMed ID: 21764020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total Internal Reflection Fluorescence (TIRF) Microscopy.
    Fish KN
    Curr Protoc; 2022 Aug; 2(8):e517. PubMed ID: 35972209
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-resolution line-scanning optical coherence microscopy.
    Chen Y; Huang SW; Aguirre AD; Fujimoto JG
    Opt Lett; 2007 Jul; 32(14):1971-3. PubMed ID: 17632613
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Resonant dielectric multilayer with controlled absorption for enhanced total internal reflection fluorescence microscopy.
    Mouttou A; Lemarchand F; Koc C; Moreau A; Lumeau J; Favard C; Lereu AL
    Opt Express; 2022 Apr; 30(9):15365-15375. PubMed ID: 35473257
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Even illumination in total internal reflection fluorescence microscopy using laser light.
    Fiolka R; Belyaev Y; Ewers H; Stemmer A
    Microsc Res Tech; 2008 Jan; 71(1):45-50. PubMed ID: 17886344
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polarization-controlled TIRFM with focal drift and spatial field intensity correction.
    Johnson DS; Toledo-Crow R; Mattheyses AL; Simon SM
    Biophys J; 2014 Mar; 106(5):1008-19. PubMed ID: 24606926
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flat-top TIRF illumination boosts DNA-PAINT imaging and quantification.
    Stehr F; Stein J; Schueder F; Schwille P; Jungmann R
    Nat Commun; 2019 Mar; 10(1):1268. PubMed ID: 30894522
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Around-the-objective total internal reflection fluorescence microscopy.
    Burghardt TP; Hipp AD; Ajtai K
    Appl Opt; 2009 Nov; 48(32):6120-31. PubMed ID: 19904308
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct characterization of the evanescent field in objective-type total internal reflection fluorescence microscopy.
    Niederauer C; Blumhardt P; Mücksch J; Heymann M; Lambacher A; Schwille P
    Opt Express; 2018 Aug; 26(16):20492-20506. PubMed ID: 30119359
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.