These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 34839431)
1. Efficacy and mortality of rotating sheaths versus laser sheaths for transvenous lead extraction: a meta-analysis. Lee SY; Allen IE; Diaz C; Guo X; Pellegrini C; Beygui R; Cardona-Guarache R; Marcus GM; Lee BK J Interv Card Electrophysiol; 2023 Aug; 66(5):1067-1075. PubMed ID: 34839431 [TBL] [Abstract][Full Text] [Related]
2. Comparison between TightRail rotating dilator sheath and GlideLight laser sheath for transvenous lead extraction. Qin D; Chokshi M; Sabeh MK; Maan A; Bapat A; Bode WD; Hanley A; Hucker WJ; Ng CY; Funamoto M; Barrett CD; Mela T Pacing Clin Electrophysiol; 2021 May; 44(5):895-902. PubMed ID: 33675073 [TBL] [Abstract][Full Text] [Related]
3. A head-to-head comparison of laser vs. powered mechanical sheaths as first choice and second line extraction tools. Zsigmond EJ; Saghy L; Benak A; Miklos M; Makai A; Hegedus Z; Alacs E; Agocs S; Vamos M Europace; 2023 Feb; 25(2):591-599. PubMed ID: 36352816 [TBL] [Abstract][Full Text] [Related]
4. Outcomes and costs associated with two different lead-extraction approaches: a single-centre study. Gaubert M; Giorgi R; Franceschi F; Koutbi-Franceschi L; Gitenay E; Maille B; Deharo JC Europace; 2017 Oct; 19(10):1710-1716. PubMed ID: 27733470 [TBL] [Abstract][Full Text] [Related]
5. Single center experience with the novel rotating dilator sheath TightRail Frei C; Hofer D; Jan S; Grebmer C; Breitenstein A J Cardiovasc Electrophysiol; 2023 Aug; 34(8):1738-1743. PubMed ID: 37343057 [TBL] [Abstract][Full Text] [Related]
6. Outcomes of transvenous lead extraction of very old leads using bidirectional rotational mechanical sheaths: Results of a multicentre study. Migliore F; Pittorru R; Dall'Aglio PB; De Lazzari M; Rovaris G; Piazzi E; Dentico A; Ferrieri A; D'Angelo G; Marzi A; Sawaf BE; Bertaglia E; Iliceto S; Gerosa G; Tarzia V; Carretta D; Mazzone P J Cardiovasc Electrophysiol; 2023 Mar; 34(3):728-737. PubMed ID: 36477909 [TBL] [Abstract][Full Text] [Related]
7. Reported mortality with rotating sheaths vs. laser sheaths for transvenous lead extraction. Diaz CL; Guo X; Whitman IR; Marcus GM; Pellegrini CN; Beygui RE; Lee SY; Lee BK Europace; 2019 Nov; 21(11):1703-1709. PubMed ID: 31545350 [TBL] [Abstract][Full Text] [Related]
8. Safety and efficacy of transvenous lead extraction in octogenarians using powered extraction sheaths. Burger H; Hakmi S; Petersen J; Yildirim Y; Choi YH; Willems S; Reichenspurner H; Ziegelhoeffer T; Pecha S Pacing Clin Electrophysiol; 2021 Apr; 44(4):601-606. PubMed ID: 33594705 [TBL] [Abstract][Full Text] [Related]
9. Outcomes of transvenous lead extraction using the TightRail™ mechanical rotating dilator sheath and excimer laser sheath. Misra S; Swayampakala K; Coons P; Cerbie C; Guifarro A; Lesiczka M; Holshouser JW; Madjarov J; Love C; Mehta R J Cardiovasc Electrophysiol; 2021 Jul; 32(7):1969-1978. PubMed ID: 34028112 [TBL] [Abstract][Full Text] [Related]
10. Safety and Efficacy of Transvenous Lead Extraction With a High-Frequency Excimer Laser - A Single Center Experience. Yoshitake T; Goya M; Sasaki T; Shiohira S; Sekigawa M; Shirai Y; Lee K; Yagishita A; Maeda S; Takahashi Y; Kawabata M; Hirao K Circ J; 2018 Nov; 82(12):2992-2997. PubMed ID: 30318499 [TBL] [Abstract][Full Text] [Related]
11. Outcomes of transvenous lead extraction in octogenarians using bidirectional rotational mechanical sheaths. Migliore F; Pittorru R; Dall'Aglio PB; De Lazzari M; Falzone PV; Sottini S; Dentico A; Ferrieri A; Pradegan N; Bertaglia E; Iliceto S; Gerosa G; Tarzia V; Carretta D Pacing Clin Electrophysiol; 2023 Aug; 46(8):960-968. PubMed ID: 36951180 [TBL] [Abstract][Full Text] [Related]
12. Outcomes of Transvenous Lead Extraction in a Referral Center in Northern Israel. Haddad R; Birati E; Zayyad H; Andria N; Nachum E; Kachel E; Marai I Isr Med Assoc J; 2024 May; 26(5):273-277. PubMed ID: 38736340 [TBL] [Abstract][Full Text] [Related]
13. Safety and success of transvenous lead extraction using excimer laser sheaths: a meta-analysis of over 1700 patients. Rinaldi CA; Diemberger I; Biffi M; Gao YR; Sizto E; Jin N; Epstein LM; Defaye P Europace; 2023 Nov; 25(11):. PubMed ID: 37757839 [TBL] [Abstract][Full Text] [Related]
14. Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths. Hakmi S; Pecha S; Sill B; Reiter B; Willems S; Aydin MA; Yildirim Y; Reichenspurner H; Treede H Interact Cardiovasc Thorac Surg; 2014 Jan; 18(1):56-60. PubMed ID: 24087832 [TBL] [Abstract][Full Text] [Related]
15. Lead extraction experience with high frequency excimer laser. Tanawuttiwat T; Gallego D; Carrillo RG Pacing Clin Electrophysiol; 2014 Sep; 37(9):1120-8. PubMed ID: 24766604 [TBL] [Abstract][Full Text] [Related]
16. Left common carotid artery to left innominate vein arteriovenous fistula after transvenous laser lead extraction. Levesque P; Plourde B; Jacques F; Charbonneau É; Audet MÈ; Poulin JF; Philippon F Pacing Clin Electrophysiol; 2022 May; 45(5):696-699. PubMed ID: 34979041 [TBL] [Abstract][Full Text] [Related]
17. Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction. Aytemir K; Yorgun H; Canpolat U; Şahiner ML; Kaya EB; Evranos B; Özer N Europace; 2016 Jul; 18(7):1043-8. PubMed ID: 26467403 [TBL] [Abstract][Full Text] [Related]
18. Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Akhtar Z; Kontogiannis C; Georgiopoulos G; Starck CT; Leung LWM; Lee SY; Lee BK; Seshasai SRK; Sohal M; Gallagher MM Europace; 2023 Nov; 25(11):. PubMed ID: 37882609 [TBL] [Abstract][Full Text] [Related]