These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 34839895)

  • 1. The missing piece of the trauma armoury-medial femoral condyle plate.
    Upadhyay P; Syed F; Ramoutar DN; Ward J
    Injury; 2022 Mar; 53(3):1237-1240. PubMed ID: 34839895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary?
    Penny P; Swords M; Heisler J; Cien A; Sands A; Cole P
    Injury; 2016 Aug; 47(8):1761-9. PubMed ID: 27264277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical treatment of femoral medial condyle fracture with lag screws and proximal tibial plate: A case report.
    Kodama H; Saku I; Tomoyama S
    Int J Surg Case Rep; 2020; 70():101-105. PubMed ID: 32416477
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.
    Grau L; Collon K; Alhandi A; Kaimrajh D; Varon M; Latta L; Vilella F
    Surg Technol Int; 2018 Jun; 32():293-297. PubMed ID: 29791694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The biomechanical cost of variable angle locking screws.
    Tidwell JE; Roush EP; Ondeck CL; Kunselman AR; Reid JS; Lewis GS
    Injury; 2016 Aug; 47(8):1624-30. PubMed ID: 27324325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reverse distal femoral locking compression plate (DF-LCP), does it fit and how to fit on Asian's proximal femurs? A cadaveric study.
    Apivatthakakul V; Apivatthakakul T
    Eur J Orthop Surg Traumatol; 2022 Jul; 32(5):991-1000. PubMed ID: 34236513
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures.
    Sohn HS; Shin SJ
    Injury; 2019 Jul; 50(7):1300-1305. PubMed ID: 31178147
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles].
    Bartoníček J; Naňka O; Tuček M
    Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
    Cullen AB; Curtiss S; Lee MA
    J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Femoral Condyles Tangential Views: An Effective Method to Detect the Screw Penetration of Femoral Condyles After Retrograde Nailing.
    Zheng ZL; Yu X; Chen W; Liu YJ; Yu KL; Wu T; Zhang YZ
    Chin Med J (Engl); 2015 Dec; 128(24):3352-6. PubMed ID: 26668151
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.
    Lazarus DE; Farnsworth CL; Jeffords ME; Marino N; Hallare J; Edmonds EW
    J Pediatr Orthop; 2018 Feb; 38(2):e97-e103. PubMed ID: 29189535
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The mechanics of internal fixation of fractures of the distal femur: a comparison of the condylar screw (DCS) with the condylar plate (CP).
    Harder Y; Martinet O; Barraud GE; Cordey J; Regazzoni P
    Injury; 1999; 30 Suppl 1():A31-9. PubMed ID: 10645367
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anterolateral distal tibia locking plate osteosynthesis and their ability to capture OTAC3 pilon fragments.
    Aneja A; Luo TD; Liu B; Domingo M; Danelson K; Halvorson JJ; Carroll EA
    Injury; 2018 Feb; 49(2):409-413. PubMed ID: 29305233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Additional fixation of medial plate over the unstable lateral locked plating of distal femur fractures: A biomechanical study.
    Park KH; Oh CW; Park IH; Kim JW; Lee JH; Kim HJ
    Injury; 2019 Oct; 50(10):1593-1598. PubMed ID: 31288939
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of the fit of modern pre-contoured distal femur plates: Expect an imperfect contour.
    Bedard JC; Tanner S; Cameron J; Jeray KJ; Adams JDJ
    Injury; 2020 Mar; 51(3):719-722. PubMed ID: 31987606
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study.
    Abe S; Koizumi K; Murase T; Kuriyama K
    BMC Musculoskelet Disord; 2021 Sep; 22(1):812. PubMed ID: 34548051
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Angulated screw placement in the lateral condylar buttress plate for supracondylar femoral fractures.
    Simonian PT; Thompson GJ; Emley W; Harrington RM; Benirschke SK; Swiontkowski MF
    Injury; 1998 Mar; 29(2):101-4. PubMed ID: 10721403
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Treatment of distal femur fractures with VA-LCP condylar plate: A single trauma centre experience.
    Campana V; Ciolli G; Cazzato G; Giovannetti De Sanctis E; Vitiello C; Leone A; Liuzza F; Maccauro G
    Injury; 2020 Aug; 51 Suppl 3():S39-S44. PubMed ID: 31703959
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.